UPM309 - 1

Network Analyzers Network Analyzers DIN 96x96 multifunction three-phase meter • • DIN 96x96 ultra compact version, only 39 mm depth Main electrical parameters measured and displayed for a cost-effective consumption analysis Version for 1 or 5A CT and for direct connection up to 6A MODBUS RTU communication by RS485 port or MODBUS TCP communication by Ethernet port Possibility to manage the instrument in remote mode by WintoolNET software or by Web interface 2 digital outputs, 1 digital input Fully bi-directional four quadrants measurements for all energies and powers Possibility to connect by PT Up to 8 MB for data recording (ENH version) Possibility to record all energy counters (ENH version) Up to 24 parameters selectable among real time measurements for MIN/AVG/MAX recording (ENH version) Accuracy class 0.5 according to IEC/EN 61557-12 for active power/energy » General features UPM309 is an innovative instrument for measurement and recording of the electrical parameters. It is particularly suitable for consumption analysis and control, with an excellent quality/price ratio. UPM309 is the ideal instrument to establish the measurement points on the plant. The instrument can communicate through the RS485 serial port by MODBUS RTU protocol or through Ethernet port by MODBUS TCP protocol. Furthermore, it is available the WintoolNET software for the instrument remote management. Web interface is also available in case of instrument with Ethernet port: a very useful function that gives the possibility to manage the instrument by any PC connected on the network. UPM309 provides fully and accurate information on the load in the measurement point and it allows to calculate the costs of the energy consumption. Data read by PC allows to generate consumption profiles, recorded values trend, alarms/events report and costs calculation as well as critical values identification. Energy audit. Monitoring system and energy control. Individual machine load monitoring. Power peak control. Switchboards, gensets, motor control centers, etc. Remote metering and cost allocation. Available the remote firmware upgrade of the instrument. » Related products

Open the catalog to page 1
UPM309 - 2

Network Analyzers » Available configurations BASIC ENH CURRENT INPUTS For 1/5A CT 115 VAC ±15% (only for instrument with RS485 port) AUXILIARY POWER SUPPLY (make one choice only) 230 VAC ±15% (only for instrument with RS485 port) 85...265 VAC / 110 VDC ±15% RS485 for MODBUS RTU communication COMMUNICATION PORT (make one choice only) Ethernet for HTTP, MODBUS TCP communication WintoolNET INSTRUMENT REMOTE MANAGEMENT Web server (only for instrument with Ethernet port) SIGN REPRESENTATION IN MODBUS PROTOCOL (make one choice only) For alarm events or pulse emissions DIGITAL INPUT To synchronise...

Open the catalog to page 2
UPM309 - 3

Network Analyzers » Measurements & recordings INSTANTANEOUS VALUES POWER FACTOR (ind∩) CURRENT THD FREQUENCY PHASE ORDER DEMAND VALUES (DMD) DMD CURRENT (abs) DMD ACTIVE POWER (imp&exp) BALANCE OF DMD SYSTEM ACTIVE POWER (+/-) DMD REACTIVE POWER (imp&exp) BALANCE OF DMD SYSTEM REACTIVE POWER (+/-) DMD APPARENT POWER (imp&exp) BALANCE OF DMD SYSTEM APPARENT POWER (+/-) DMD POWER FACTOR (imp&exp) MAX ACTIVE POWER (imp&exp) MAX REACTIVE POWER (imp&exp) MAX APPARENT POWER (imp&exp) MAX POWER FACTOR (imp&exp) MAX TANGENT Ø (imp&exp) MAX VOLTAGE THD MAX DMD ACTIVE POWER (imp&exp) MAX DMD REACTIVE...

Open the catalog to page 3
UPM309 - 4

Network Analyzers » Specifications POWER SUPPLY Voltage range (according to the model): Instrument with RS485 port: 230 VAC ±15% 115 VAC ±15% on request 85...265 VAC / 110 VDC ±15% on request Instrument with Ethernet port: 85...265 VAC / 110 VDC ±15% 300 V CAT III 50/60 Hz Safety: Frequency: VOLTAGE INPUTS Maximum measurable voltage: Safety: Minimum voltage for FFT calculation: Input impedance: Frequency: CURRENT INPUTS Maximum value: Starting current (Ist): CT burden: Minimum current for FFT calculation: 600 VAC L-L 300 V CAT III 20/35 VAC (multiplied by PT ratio in case of PT use) with...

Open the catalog to page 4
UPM309 - 5

Network Analyzers POWER SUPPLY COMMUNICATION PORT APPARENT EN. with SIGN BIT in Modbus COUNTER (VAh) SEPARATED RS485 ETHERNET Ind&Cap REMOTE MANAGEMENT OPTIONS AVAILABLE ONLY ON REQUEST ( MOQ 30 PCS ) 2'S COMPLEMENT for sign representation in Modbus protocol TOTAL apparent energy counters (Ind+Cap) PNP type digital outputs 115VAC ±15% or 85...265VAC/110VDC ±15% power suppply To be indicated together with the selected order code from the list above. Reduced parameter set and functions - 1MB memory, active&reactive power AVG recording. Extended parameter set and functions - 8MB memory, real...

Open the catalog to page 5

All Algodue Elettronica catalogs and technical brochures

  1. MFC190

    3 Pages

  2. RPS50

    3 Pages

  3. UEM80-2D

    4 Pages

  4. UEC80-D

    4 Pages

  5. UEC1P5-D

    4 Pages

  6. UEM80

    4 Pages

  7. UPA20

    5 Pages

  8. FCA3000

    3 Pages

  9. UEM6C

    4 Pages

  10. UPM209RGW

    5 Pages

  11. UPM309RGW

    5 Pages

  12. UEC1P5-D

    4 Pages

  13. UEM40-2C R70

    4 Pages

  14. UEM63-4D R70

    4 Pages

  15. UEM80-2D

    4 Pages

  16. UEM1P5

    4 Pages

  17. UEC80-2D

    4 Pages

  18. RPS51

    3 Pages

  19. FCA3000

    3 Pages

  20. UEC40 UEM40

    4 Pages

  21. UPM SERIES

    9 Pages

  22. UPA SERIES

    8 Pages

Archived catalogs

  1. DEDALO

    2 Pages