Catalog excerpts
63A three phase energy meter with built-in communication • For RS485 Modbus RTU/ASCII communication Fully bi-directional 4-quadrant measurements for all energies and powers For 4 wire networks with balanced or unbalanced load S0 output for energy pulse emission Available with MID certification » General features 4 DIN modules energy meter for the energy measurement in industrial and civilian application, with RS485 Modbus RTU/ASCII built-in communication. Available with MID certification suitable for billing. Besides the energy, the meter can measure the main electrical parameters and makes them available on the built-in COM port. The LCD display shows the energies and the instantaneous powers. The COM port allows to manage the connected meter by a remote station. Data is transmitted on a RS485 line. Moreover, a dedicated application for remote management is provided: • Modbus Master software > for energy meter management by PC in RS485 Modbus network. The meter is built according to EN 50470-1 standard. The active energy is compliant to IEC/EN 62053-21 class 1, but for MID certified device it moreover fulfills class B requirements according to EN 50470-3. The accuracy of reactive energy is compliant to IEC/EN 62053-23 class 2. Wide backlighted LCD display with clear graphic symbols comprehensible at a glance. Metrological LED on front panel and sealable terminal covers. The analysis of the MTBF values, the accurate selection of components and the reduction of the internal working temperatures together with strict production and control standards guarantee a product with an excellent quality and a long lasting reliability. Totalization of the electric energy in the industry for each single line or machine. Measurement of energy generated by renewable sources such as solar, eolic, etc. Accounting and billing of consumptions in camp sites, malls, residential areas, naval ports, etc. Totalization of the electric consumption in hotels, congress centers, exhibition fairs. Accounting of the consumptions in buildings with executive office services. Internal allocation of the consumptions in timeshare civilian and industrial buildings. Realization of energy monitoring systems. Remote survey of the consumptions and compute of the costs. Remote management through dedicated application/ interface. Up to 30 instantaneous measurements, complete set of energy counters and partial counters. Moreover partial counters can be started, stopped or reset. Phase sequence and diagnostic function for error signalling in case of wrong polarity connection. Available MID according to Swiss market (MID S). Reactive energy is not shown on energy meter display. » Related products • Modbus Master software (for Windows OS)
Open the catalog to page 1» Technical features Power supply • • • • Voltage range & frequency • Power supplied from the voltage circuit Nominal measurement voltage ±20% Max consumption (for each phase): 3.5 VA - 1 W Nominal frequency: 50/60 Hz Passive optoisolated Maximum values: 27 VDC - 27 mA Meter constant: 100 imp/kWh Starting current Ist: 20 mA Minimum current Imin: 250 mA Transitional current Itr: 500 mA Reference current Iref (Ib): 5 A Maximum current Imax: 63 A The measuring unit (imp/kWh, imp/kvarh, imp/kVAh) changes according to the assigned counter (kWh, kvarh, kVAh) Tariff input • • Active energy class 1...
Open the catalog to page 24 WIRE COM MEASURE UNIT, DISPLAY PORT VALUE or STATUS SYSTEM Phase voltage Line voltage System voltage Phase current Neutral current System current Phase power factor System power factor Phase apparent power System apparent power Phase active power System active power Phase reactive power System reactive power Phase sequence Power direction Phase active energy System active energy Phase inductive and capacitive reactive energy System inductive and capacitive reactive energy Phase inductive and capacitive apparent energy System inductive and capacitive apparent energy Tariff 1/2 phase active...
Open the catalog to page 3UEM63-4D R70 VOLTAGE AND FREQUENCY INPUT INPUTS/ OUTPUTS TARIFF input COMMUNICATION PORT LEGEND MID: MID certified meter, with reset function only on partial counters. MID S: MID certified meter, with reset function only on partial counters, without reactive energy counters on display (only SWITZERLAND NO MID: Meter without MID certification, with reset function only on partial counters. RESET: Meter without MID certification, with RESET function on ALL counters. Software for meter remote management (MODBUS Master) downloadable for free at www.algodue.com NOTE: Subject to change without...
Open the catalog to page 4All Algodue Elettronica catalogs and technical brochures
-
Rogowski coils Catalogue
26 Pages
-
MFC190
3 Pages
-
MFC150-Ul SERIES
4 Pages
-
MFC150 SERIES
4 Pages
-
ALGODUE COMPANY PROFILE
8 Pages
-
[Presentation] PQM4000
15 Pages
-
MFC140-UI SERIES
4 Pages
-
MFC140 SERIES
4 Pages
-
RPS50
3 Pages
-
UEM80-2D
4 Pages
-
UEC80-D
4 Pages
-
UEM80
4 Pages
-
UPA20
5 Pages
-
UEM6C
4 Pages
-
UPM209RGW
5 Pages
-
ROGOWSKI COILS
7 Pages
-
UPM309RGW
5 Pages
-
UEC1P5-D
4 Pages
-
UEM40-2C R70
4 Pages
-
UPM209 ‹TA 1/5A, 80A direct›
5 Pages
-
GENERAL CATALOGUE
5 Pages
-
UPA30 / UPA41
5 Pages
-
MID ENERGY METERS CATALOGUE
14 Pages
-
Current transformers
13 Pages
-
UEM1P5
4 Pages
-
UEC80-2D
4 Pages
-
RPS51
3 Pages
-
FCA3000
3 Pages
-
UEC40 UEM40
4 Pages
-
UPM309
5 Pages
-
Communication modules
3 Pages
-
Plug-in modules for UPA
3 Pages
-
NETWORK ANALYZERS CATALOGUE
23 Pages
-
SMART KIT PRESENTATION ENG
8 Pages
-
UPM SERIES
9 Pages
-
UPA SERIES
8 Pages
Archived catalogs
-
UPM209-309Smart Kit_report
10 Pages
-
DEDALO
2 Pages
-
2017 General catalogue
8 Pages
-
Company profile
12 Pages