Overview
Innovative Electronic Systems offers compact communication modules designed for integration with MID Energy Meters, specifically the UEC1P5, UEC6C, and UEC80 series. These modules facilitate easy and efficient communication with energy meters through an optical port, eliminating the need for physical connections. The modules are adaptable for various applications and include RS485 Modbus, M-Bus, and LAN Gateway options.
Specifications
The communication modules are compatible with 6A three-phase, 80A three-phase, and 80A single-phase energy meters. They are compact, occupying 1-2 DIN modules, and are designed for both industrial and civilian applications.
RS485 Modbus Module
This module enables data collection and transmission from the connected meter to a remote station using the RS485 line with MODBUS RTU or ASCII protocols. It features a SET DEFAULT key for resetting communication parameters and includes LEDs indicating power supply and communication status.
M-Bus Module
The M-Bus module supports data collection and transmission using the M-Bus protocol, a European standard for remote meter reading. It comes with dedicated software for configuration and measurement display.
LAN Gateway Module
The LAN Gateway module allows management of a single energy meter via any PC connected to the Internet/LAN using a web browser. It supports MODBUS TCP protocol, providing a scalable solution. The module includes a SET DEFAULT key for resetting parameters and LEDs for link activity and status.
Ordering Information
The document lists various models of communication modules, each with specific power supply requirements and communication ports. User manuals are available in multiple languages, including Italian, English, German, and French.
Additional Resources
Software for remote meter management, such as MODBUS Master and M-BUS Master, is available for free download from the manufacturer's website.
See more

Catalog excerpts

Communication modules-1

Communication modules To be combined with UEC1P5, UEC6C & UEC80 series • • • • Compact size (1-2 DIN modules) Easy to use: no physical connection thanks to optical port to be combined with the energy meter Possibility to switch the use of the communication module according to the required application Modules: RS485 Modbus, M-Bus, LAN Gateway » General description Compact communication modules suitable for managing energy meters in industrial and civilian application. Thanks to the optical port, the communication with energy meters is quick and easy. All modules can be combined with the following meters: • 6A three phase RS485 Modbus RS485 module allows to collect and transmit measurements data of the connected meter to a remote station. This data is transmitted on a RS485 line, using MODBUS RTU or ASCII protocols. MODBUS is the most popular communication protocol designed to allow industrial equipment to communicate. RS485 module is provided with a SET DEFAULT key to reset all communication parameters to factory default values. This function is very useful, i.e. in case of MODBUS logical address forgotten. Two LEDs on the RS485 module provide information about power supply status and communication status. M-Bus M-Bus module allows to collect and transmit measurements data of the connected meter to a remote station using M-Bus protocol. M-Bus (Meter-Bus) is a European standard for the remote reading of consumption meters. A free dedicated software is provided for module configuration and for displaying the detected measurements. LAN Gateway LAN Gateway module allows to manage a single energy meter by any PC connected to Internet/LAN by means of a simple web browser. LAN Gateway module web pages are designed to be cross browser compliant: Internet Explorer, Mozilla Firefox, Apple Safari, Google Chrome, Opera, Netscape navigator are all supported web browsers. Another supported feature is MODBUS TCP protocol. MODBUS TCP is the most popular communication protocol designed to allow industrial equipment to communicate over a network. The use of MODBUS TCP provides a totally scaleable solution according to the needs. LAN Gateway module is provided with a SET DEFAULT key to reset all communication parameters to factory default values. This function is very useful, i.e. in case of IP address forgotten. Two LEDs on LAN Gateway module provide information about link activity and status. 1 Innovative Electronic Systems

 Open the catalog to page 1
Communication modules-2

Communication modules » Technical drawing RS485 Modbus, M-Bus communication modules LAN Gateway communication module 2 Innovative Electronic Systems

 Open the catalog to page 2
Communication modules-3

Communication modules POWER SUPPLY USER MANUAL LANGUAGES COMMUNICATION PORT COMMUNICATION MODULES Softwares for meter remote management (MODBUS Master, M-BUS Master) downloadable for free at www.algodue.com NOTE: Subject to change without notice Innovative Electronic Systems Via P. Gobetti, 16/F - 28014 Maggiora (NO) - Italy - Tel.: +39 0322 89307 [email protected] - www.algodue.com 72PG

 Open the catalog to page 3

All Algodue Elettronica catalogs and technical brochures

  1. UEM2L, UEM4L

    7  Pages

  2. MFC190

    3  Pages

  3. MFC150 SERIES

    4  Pages

  4. RPS51

    3  Pages

  5. MFC140 SERIES

    4  Pages

  6. RPS50

    3  Pages

  7. UEM80-2D

    4  Pages

  8. UEC80-D

    4  Pages

  9. UEM80

    4  Pages

  10. UPA20

    5  Pages

  11. UEM6C

    4  Pages

  12. UPM209RGW

    5  Pages

  13. UPM309RGW

    5  Pages

  14. UEC1P5-D

    4  Pages

  15. UEM40-2C R70

    4  Pages

  16. UEM63-4D R70

    4  Pages

  17. UPA30 / UPA41

    5  Pages

  18. UEM1P5

    4  Pages

  19. UEC80-2D

    4  Pages

  20. FCA3000

    3  Pages

  21. UEC40 UEM40

    4  Pages

  22. UPM309

    5  Pages

  23. UPM SERIES

    9  Pages

  24. UPA SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.