1. Catalogs
  2. Alfa Laval
  3. CPM Constant-Pressure Modulating Valve

CPM Constant-Pressure Modulating Valve
1 /4Pages

CPM Constant-Pressure Modulating Valve

CPM Constant-Pressure Modulating Valve
1 /4Pages

Catalog excerpts

CPM Constant-Pressure Modulating Valve-1

ky Control the Pressure of your System CPM Constant-Pressure Modulating Valve Concept CPMI-2, CPMI-D60 and CPMO-2 are sanitary constant-pressure valves. CPMI-2 and CPMI-D60 (Constant-Pressure Modulating Inlet) maintain a constant pressure in the process line at the inlet side of the valve. Typical applications are after separators, heat exchangers or overflow valves. CPMO-2 (Constant-Pressure Modulating Outlet) maintains a constant pressure in the process line at the outlet side of the valve. Typical applications are before filling/bottling machines etc. Working principle The valves are remote-controlled by means of compressed air. A diaphragm/valve plug system reacts immediately to any alteration of the product pressure and changes position so that the preset pressure is maintained. Standard design The CPMI-2 and CPMO-2 consist of a valve body with valve seat, cover, a valve plug with a diaphragm unit and a clamp. The cover and the valve body are clamped together. The valve body and the seat are welded together. The CPM-I-D60 consists of upper and lower valve bodies, an inlet tube, a cover, a valve plug with diaphragm unit and clamps. The cover and the valve bodies are clamped together. . TECHNICAL DATA PHYSICAL DATA Max. product pressure: . . . . . . . . . . 1000 kPa (10 bar). Min. product pressure: . . . . . . . . . . 0 kPa (0 bar). Temperature range: . . . . . . . . . . . . . 10°C to 95°C (EPDM). Temperature range with upper diaphragm in PTFE/EPDM: . . . . . . . . . . . . . . . 10° C to +140° C. (Higher on request). Air pressure (CPMI-2/CPMO-2): . . . . . 0 to 800 kPa (0 to 8 bar). Air pressure (CPM-I-D60): . . . . . . . . 0 to 600 kPa (0 to 6 bar). Flow Kv 23, fully open (Dp = 1 bar): . . Approx 23 m3/h. Flow Kv 7 (∆p = 1 bar): . . . . . . . . . . Approx 7 m3/h. Flow Kv 9 (∆p = 1 bar): . . . . . . . . . . Approx 9 m3/h. Flow Kv2/15, low capacity (∆p = 1 bar): Approx 2 m3/h. (Alternative size) . . . . . . . . . . . . . . . (regulating area). Approx. 15 m3/h. (CIP area). Flow range Kv60, fully open (∆p = 1 bar) (CPM-I-D60) . . . . . . . . . . . . . . . . . Approx 60 m3/h. Materials Product wetted steel parts: Other steel parts: . . . . . . Lower diaphragm: . . . . . . Upper diaphragm . . . . . . Air Connections R 1/4" (BSP), internal thread. 1.4404 (316L). 1.4301(304). PTFE covered EPDM rubber NBR

 Open the catalog to page 1
CPM Constant-Pressure Modulating Valve-2

Options A. Male parts or clamp liners in accordance with required standard. B. Air pressure regulating valve kit, 0-8 bar. C. Air throttling valve for adjustment of regulating speed for the CPM-2 valve. D. Booster for product pressure exceeding the available air pressure. (Product pressure = 1.8 x air pressure). E. US 3A version available on request for CPM-2 valves only Diaphragm Unit CPMI-2 and CPMO-2: The diaphragm unit consists of a stainless steel disc which is divided into sectors and of flexible diaphragms which are placed on each side of the sectors. CPM-I-D60: The diaphragm unit consists...

 Open the catalog to page 2
CPM Constant-Pressure Modulating Valve-3

Pressure drop/capacity diagrams For all diagrams the following applies: Measurement: In accordance with VDI 2173. Alfa Laval recommend max. flow velocity in tubing and valves to be 5 Select: CPM-2, Kv 23 which at working point will be 48% open. Select: CPMI-2, Kv 2/15 which at working point will be approx. 35% open equal to about 50% of the regulating area. Example of using the diagram: Always try to get as close as possible to the 50% open curve. If the CPM-I-D60 is too big select from the CPMI-2 curves.

 Open the catalog to page 3
CPM Constant-Pressure Modulating Valve-4

OD (Inch/DN) ID (Inch/DN) t (Inch/DN) E (Inch/DN) F G G1 G2 H M/ISO clamp M/ISO male M/DIN male M/SMS male M/BS male Seat diameter Weight (kg) Alfa Laval reserves the right to change specifications without prior notification. ALFA LAVAL is a trademark registered and owned by Alfa Laval ESE00284EN 1406 How to contact Alfa Laval Contact details for all countries are continually updated on our website. Please visit www.alfalaval.com to access the information direct.

 Open the catalog to page 4

All Alfa Laval catalogs and technical brochures

  1. PureSOx

    12  Pages

  2. Arctigo HRCD

    2  Pages

  3. Heat exchangers

    16  Pages

  4. BDB 104

    2  Pages

  5. Pressosmart

    4  Pages

  6. SolarTank

    2  Pages

  7. Alfa Disc

    2  Pages

  8. ISC II

    2  Pages

  9. Aquastore

    4  Pages

  10. AquaProtect T

    2  Pages

  11. Tank Cover

    1  Page

  12. Level switch

    3  Pages

  13. Pharma-line

    2  Pages

  14. Alfie500

    2  Pages

  15. Alfapure2000

    2  Pages

  16. AlfaPure Z7

    2  Pages

  17. AlfaPure Z3

    2  Pages

  18. AlfaCond

    2  Pages

  19. NF series

    4  Pages

  20. FSM series

    3  Pages

  21. WS 40, 60

    4  Pages

  22. WS 10, 20 ,30

    4  Pages

  23. SG2 700

    2  Pages

  24. Foodec 800

    4  Pages

  25. Foodec 600

    2  Pages

  26. Foodec 500

    4  Pages

  27. Foodec 400

    4  Pages

  28. Foodec 300

    2  Pages

  29. Foodec 200

    2  Pages

  30. Foodec 100

    2  Pages

  31. WideGap 350

    2  Pages

  32. WideGap 200

    2  Pages

  33. TL6

    2  Pages

  34. TL3

    2  Pages

  35. TL15

    2  Pages

  36. M6

    2  Pages

  37. M3

    2  Pages

  38. M15

    2  Pages

  39. M10

    2  Pages

  40. AlfaNova 14

    2  Pages

  41. CBXP52

    2  Pages

  42. CB77

    2  Pages

  43. CB60 / CBH60

    2  Pages

  44. CB52 / CBH52

    2  Pages

  45. CB400

    2  Pages

  46. CB27 / CBH27

    2  Pages

  47. CB20

    2  Pages

  48. CB18 / CBH18

    2  Pages

  49. CB16 / CBH16

    2  Pages

  50. CB14

    2  Pages

  51. AXP10

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.