Catalog excerpts
VENTILATION Filter Fans High performance and fast mounting Modern design A positive visual impact is given by the up-to-date design of the grills and the minimal external projection. All moulded parts are made of highly resistant and self-extinguishing ABS, UL94 VO grade. The standard coIor is RAL 7035. RAL 7032 is also available. On request and for substantial quantities, non standard colors are also available. Fast installation Installation is fast thanks to the simple square cut-out on the enclosure panel and to the snap-in fixing system. No screws are needed. The snap-in fixing system can be used on panels with thickness in the range 1.2 - 2.4 mm. For different thickness, fixing can still be done with the screw kit included in each pack for this purpose. Wide range of air flow ratings The range of air flow ratings goes from 24 to 630 m3/h. For all filter fans, default air flow direction is from the outside towards the inside of the enclosure. If needed the user can easily reverse the direction by simply re-assembling the fan in the opposite way (only on specified models). No interference outside the enclosure 5 mm is the maximum projection outside the enclosure. This means no problems during transportation and enclosure operational life, typical instead of the bigger and cumbersome traditional units. High reliability Alfa Electric only uses the best quality ball bearing fans. They ensure a high efficiency and have an expected life of 30.000 working hours at an ambient temperature of 55°C. They are all designed to ensure a quick and safe electrical connection. Optimal enclosure protection The special configuration of the grill, the self-adhesive gasket and the filter mat ensure an IP54 protection degree towards the enclosure. Power supply Alfa Electric filter fans are available in the following AC supply voltages: 230V single-phase, 115V single-phase and 400V three-phase, all bi-frequency 50-60 Hz. In addition, 24 and 48VDC versions are available up to 230 m3/h. On request they can also be available with other rated voltages not shown in this catalogue. Filter units To achieve optimal cooling air circulation, filter fans are used together with filter units. Filter units are available in four different sizes and have the same design of the external part of a filter fan. ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice. Cooling performance diagram Air flow rate (m³/hr) Waste heat to be removed 500W Temperature difference 20K Air flow required 78m3/hr Filter fan unit solution: When selecting a Filter Fan unit, always keep a margin of at least l0% to compensate for any air flow decay due to filter mat clogging.
Open the catalog to page 1Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Connection with terminals Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Power cord 1m Fan speed controller Hood for IP55 ALFAA000BPUB ALFAA500BPUB ALFAA510BPUB ALFAA512BPUB ALFAA524BPUB delete B delete B, add N (available on request) M PR K - TIP If possible it is better to use the units with the air flow from the outside to the enclosure inside. The slight pressurization of the panel prevents dust from getting through any...
Open the catalog to page 2Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Connection with terminals Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Power cord 1m Fan speed controller Hood for IP55 ALFA1000BPUB ALFA1600BPUB ALFA1610BPUB ALFA1524BPTUB ALFA1548BPTUB delete B delete B, add N (available on request) M PR K - TIP If you are using the high filtering capacity filter mat remember that air flow rate will decrease. ael-cat-en-15.01 - Specifications, values and drawings are subject to change without...
Open the catalog to page 3Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Connection with terminals Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Power cord 1m Fan speed controller Hood for IP55 ALFAB000BPUB ALFAB500BPUB ALFAB510BPUB ALFAB524BPTUB ALFAB548BPTUB delete B delete B, add N (available on request) M PR K - The filter fan unit can be switched on by a thermostat that will power it only when the temperature exceeds a set threshold (e.g. 35°C). The fan works only when cooling is needed which...
Open the catalog to page 4Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Connection with terminals Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Power cord 1m Fan speed controller Hood for IP55 ALFA2000BPUB ALFA2300BPUB ALFA2310BPUB ALFA2324BPTUB ALFA2348BPTUB delete B delete B, add N (available on request) M PR K - TIP DC powered filter fan units can be the best way to prevent EMC interference to monitors and other sensitive equipment inside the enclosure. ael-cat-en-15.01 - Specifications, values...
Open the catalog to page 5Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Fan speed controller Hood for IP55 ALFA2000BPUB ALFA2500BPUB ALFA2510BPUB ALFA2524BPTUB ALFA2548BPTUB ALFA2600BPUB ALFA2610BPUB delete B delete B, add N (available on request) M PR ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice. Features Air flow rate (free blow) Flow rate with exit filter Power supply Dimensions HxWxD Power consumption...
Open the catalog to page 6Versions UL RAL7032 - Gray - Code ending RAL9005 - Black - Code ending EMC - Code ending Reverse flow - Code ending Accessories Filter mat, standard type Filter mat, high efficiency Thermostat 0-60°C, NO contact Fan speed controller Hood for IP55 ALFA3000BPUB ALFA3500BPUB ALFA3510BPUB ALFA3600BPUB delete B delete B, add N (available on request) M PR ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice. Features Air flow rate (free blow) Flow rate with exit filter Power supply Dimensions HxWxD Power consumption Current consumption Overcurrent protection...
Open the catalog to page 7All Alfa Electric catalogs and technical brochures
-
Lightning
5 Pages
-
CONTROL
11 Pages
-
HEATING
10 Pages
-
Air Conditioning
5 Pages