CONTROL - 1

Compact Thermostat for DIN 35 mm. rail mounting. Based on bimetallic junction, provides high capacity NO or NC contact. Two versions available: Typically used for controlling ventilation devices Typically used for controlling heaters Accessories DIN rail bracket Unit °C °C °C A A W mOhm cycles °C (°F) °C (°F) mm g ±4 7 10 (1.6) 15 (2.5) 30 Thermostatic bimetal Snap action < 10 > 100,000 2-pole terminal for 2.5 mm² wire PA6, UL94 V0 self-estinguishing, light grey RAL 7035 IP20 -25/+80 (-13/+176) -45/+80 (-49/+176) Clip for mounting on DIN rail 35 mm EN50022 Variable CE - UL 61x34x35 48 GUIDADINPL ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice. Features Contact function Temperature setting range Precision Hysteresis Max. switching current 250Vac resistive load (inductive load) 125Vac resistive load (inductive load) Max. switching power in Vdc Temperature sensor type Contact type Contact resistance Service life Electrical connections Casing Protection degree EN60529 Operating temperature Storage temperature Mounting Installation position Conformity Dimensions HxWxD Weight

Open the catalog to page 1
CONTROL - 2

THRV - THVV DOUBLE-THERMOSTATS Compact double thermostat for DIN 35 mm. rail mounting. Based on bimetallic junction, provide high capacity and separated NO and NC contacts in different combinations. Three versions available: Features Contact function Temperature setting range Precision Hysteresis Max. switching current: at 250Vac resistive load (inductive load) at 125Vac resistive load (inductive load ) Max. switching power in Vdc Temperature sensor type Contact type Contact resistance Service life Electrical connections Casing Protection degree EN60529 Operating temperature Storage...

Open the catalog to page 2
CONTROL - 3

THVF - THRF BIMETALLIC THERMOSTAT FIXED SET Fixed set point compact thermostat for DIN 35 mm. rail mounting. Based on bimetallic junction, provides high capacity NO or NC contact. Two versions available: Typically used for controlling ventilation devices Typically used for controlling heaters Accessories DIN rail bracket Unit °C °C A A W mOhm cycles °C (°F) °C (°F) mm g 5 (1.6) 10 (2.0) 30 Thermostatic bimetal Snap action < 10 > 100,000 2-pole terminal for 2.5 mm² wire PA6, UL94 V0 self-estinguishing, light grey RAL 7035 IP20 -40/+80 (-40/+176) -45/+80 (-49/+176) Clip for mounting on DIN...

Open the catalog to page 3
CONTROL - 4

CONTROL THSTHERMOSTAT CHANGE-OVER CONTACT WITH LOW HYSTERESIS Features ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice. 36 www.alfaelectric.com QLFQ .SCTRIC

Open the catalog to page 4
CONTROL - 5

CONTROL Hygrostat CONTROL Hygrostat EUHHYGROSTATElectronic Hygrostat for DIN 35 mm. rail mounting. Typically used to control enclosure heaters. LED display of power on and status. Features DIN rail bracket | GUIDADINPL | GUIDADINPL lQLFP ELECTRIC OOOOOO II LJ I I1—'I I LJ II ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.

Open the catalog to page 5
CONTROL - 6

CONTROL Thermo-Hygrostat CONTROL Thermo-Hygrostat ETUHTHERMO-HYGROSTAT Electronic Hygrothermostat for DIN 35 mm. rail mounting. Typically used to control enclosure heaters. The change over contact triggers either for high humidity or low temperature, independently set adjustable. LED display of power on and status. DIN rail bracket | GUIDADINPL | GUIDADINPL ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.

Open the catalog to page 6
CONTROL - 7

MECHANICAL HYGROSTAT Hygrostat for DIN 35 mm. rail mounting. Typically used to control enclosure heaters. DIN rail bracket I GUIDADINPL ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.

Open the catalog to page 7
CONTROL - 8

CONTROLETHM - ETHDMTEMPERATURE CONTROLLERS Compact Size - 1 DIN Module (1 7,5mm) or 2 DIN modules (35mm) Supply 20-30 VAC/DC or 200-240 VAC Din rail mounting Analog temperature adjustment Suitable for temperature control inside electric panel (Fan control and resistor control) One or two independent NTC probe inputs 1 relay output x 8A (ETHM1 0,ETHM14), 2 relay outputs x 1 6A (ETHDM1 0, ETHDM14) ETHM ETHDM Power on LED Relay Output LED - The ETHDM10 and ETHDM14 are factory equipped with an integral NTC on the thermostat (terminals 1-2) and a bridge between terminals 2 and 1A. In this...

Open the catalog to page 8
CONTROL - 9

ETH - ETHDTEMPERATURE CONTROLLERS Compact Size - 1 DIN Module (17,5mm) or 2 DIN modules (35mm) Supply 10-30AC/DC or 200-240VAC Din rail mounting Digital adjustment of tempearture (2 red digit) Appropriate for temperature control inside electric panel (fan and resistor control) NTC probe input 1 or 2 relay outputs Power supply DIMENSIONS (mm) WIRING DIAGRAM ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.

Open the catalog to page 9
CONTROL - 10

CONTROL FSCFAN SPEED CONTROLLER Electronic temperature-regulated fan speed controller for DIN 35 mm. rail mounting. Speed controller helps to reduce fan noise, air flow rate is reduced to the optimum speed required. DIN rail bracket I GUIDADINPL 42 ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.

Open the catalog to page 10
CONTROL - 11

FS FLASHING SAFETY DEVICE The flashing safety devices series FS prevents accidents, alerting the operator that the electrical system is live. The FS devices are suitable for connection to three or single-phase lines. FS is also a phase-loss and phase-sequence control device: in case of failure, it points out the missing phase. The device functions can be increased with auxiliary contacts that allow to switch-on the lamp when opening the cabinet door or to control other equipment inside the cabinet (air conditioner, etc.) FIN - DOOR LIMIT SWITCH Required on most enclosures for safety and...

Open the catalog to page 11