MODELS AND POWER The range of air conditioners ALFA ELECTRIC includes several productions depending on voltages and different type of thermostat mounted. The code varies about voltage and control instrumentation. CODE EXAMPLE AND COMPOSITION: Cooling power at 35°C inside the cabinet and 35°C outside cabinet (x 10W) (b Power supply: 0=230 V monophase 50/60 Hz 1=115 V monophase 50/60 Hz 2 = 400 V monophase 50/60 Hz Type of thermostat: 0=mechanical thermostat 1=digital thermostat DIGITAL THERMOSTAT The version with the number 1 as the last digit coding are equipped with digital thermostat that allows to implement various control operations: 1 setting ignition temperature compressor 2 setting temperature compressor shutdown 3 Set delay on / off the compressor in terms of temperature 4 Setting the standard period of the compressor to avoid the phenomenon of intermittent on/off. This phenomenon is very detrimental to the proper operation of the air conditioner. 5 Setting the maximum value allowed for the overcoming of the maximum temperature in the cabinet, after which the thermostat emits an alarm 6 Setting the delay time of the alarm switch LOW MAINTENANCE ALFA ELECTRIC air conditioners require little maintenance on all models through the adoption of heat exchanger with a pitch between the fins is not less than 4 mm. The fins are treated to reduce the adhesion of dirt. ROTARY COMPRESSOR ALFA ELECTRIC air conditioners are distinguished by the adoption on most models of rotary compressors. This type of compressors, unlike the more common alternative compressors allowed to contain the clutter in favour of a greater distance between inlet hot air from the context and delivery of fresh air into the framework. The greater distance allows the reduction of the phenomenon of by-pass, using a greater amount of fresh air produced. OUTDOOR VERSION For all models is available the outdoor version. These units have a special cover designed to protect internal components, a condenser fan controller in according to the condensation pressure and pressure controller for the safety of compressor. On request is available a heater band to protect compressor in low ambient temperature. LESS WEIGHT AND LESS VIBRATION The rotary compressor also reduces the weight of the unit with obvious benefits in the transport, handling and installation of the machine. The lower vibrations due to a lower inertia of the moving parts make this component quiet and durable. GREATER EFFICIENCY The rotary compressor has considerable advantages over the alternative compressor: among them being the biggest isentropic efficiency mainly due to different internal cooling which favors compression. The absence of valves in suction and dead volumes, typical of alternative systems, reduces the loss of gas pressure. ael-cat-en-15.01 - Specifications, values and drawings are subject to change without notice.
Open the catalog to page 1Inside cabinet temperature (°C) Air flow rate (free blow) inside outside Max current Delayed fuse Absorbed electric power EN814 A35A35 Absorbed electric power EN814 A35A50 Refrigerant (type/charge) Maximum Pressure Operating temperature (ambient) Operating temperature (enclosure) Temperature controller (factory set at 35°C) Compressor type Noise level Electrical connection Protection degree EN60529/1 enclosure inside Protection degree EN60529/1 ambient inside Weight (with packaging) Colour Conformity/Certifications Versions Outdoor Integrated mechanical thermostat Integrated digital...
Open the catalog to page 2Inside cabinet temperature (°C) Air flow rate (free blow) inside outside Max current Delayed fuse Absorbed electric power EN814 A35A35 Absorbed electric power EN814 A35A50 Refrigerant (type/charge) Maximum Pressure Operating temperature (ambient) Operating temperature (enclosure) Temperature controller (factory set at 35°C) Compressor type Noise level Electrical connection Protection degree EN60529/1 enclosure inside Protection degree EN60529/1 ambient inside Weight (with packaging) Colour Conformity/Certifications Versions Outdoor Integrated mechanical thermostat Integrated digital...
Open the catalog to page 3Inside cabinet temperature (°C) Air flow rate (free blow) inside outside Max current Delayed fuse Absorbed electric power EN814 A35A35 Absorbed electric power EN814 A35A50 Refrigerant (type/charge) Maximum Pressure Operating temperature (ambient) Operating temperature (enclosure) Temperature controller (factory set at 35°C) Compressor type Noise level Electrical connection Protection degree EN60529/1 enclosure inside Protection degree EN60529/1 ambient inside Weight (with packaging) Colour Conformity/Certifications Versions Outdoor Integrated mechanical thermostat Integrated digital...
Open the catalog to page 4Inside cabinet temperature (°C) Air flow rate (free blow) inside outside Max current Delayed fuse Absorbed electric power EN814 A35A35 Absorbed electric power EN814 A35A50 Refrigerant (type/charge) Maximum Pressure Operating temperature (ambient) Operating temperature (enclosure) Temperature controller (factory set at 35°C) Compressor type Noise level Electrical connection Protection degree EN60529/1 enclosure inside Protection degree EN60529/1 ambient inside Weight (with packaging) Colour Conformity/Certifications Versions Outdoor Integrated mechanical thermostat Integrated digital...