OPL-403 METER RUN according to EN ISO 5167:2005 for D ≥ 50 mm ASME-MFC-14M-2003 for D < 50 mm Detailed dimensional information is presented on the construction drawings issued by Alf-Sensor for approval. Meter runs are used in two cases: 1. Required measurement accuracy is better than 1% DN of pipeline (or measuring section) <2”. In this case computations should be executed according to ASME-MFC-14M-2003 standard. Note: Buyer shall submit calculation sheet of element, if done by him. Otherwise Al-Sensor can make calculation on the base of FLOW QUESTIONNAIRE filled in by Buyer. METER RUN, remote dP transmitter connection METER RUN, compact dP transmitter connection The standard lengths of Meter Run is 900mm for DN25 (NPS 1”) and 1300 for DN40 (NPS 1,5”) ALF-SENSOR Sp. J. seat: ul. Narcyzowa 3, 31-342 Kraków manufacturing plant: ul. Krakowska 294, 32-080 Zabierzów Phone: (+48) 12 258 08 40 | Fax: (+48) 12 258 08 48 | E-mail: [email protected] www.alf-sensor.com © Copyright ALF-SENSOR Sp. J. , 2
Open the catalog to page 11^ Nominal Pipe Diameter, DN or NPS F Process Fluid State liquid * Bore diameter is calculated by Alf-Sensor on the base of FLOW QUESTIONNAIRE filled in by Buyer Note: Internal diameter of pipeline could be changed after preparing strength calculations OPL-403-DN40-PN40/B1-40,2-30,02-1.4404-steam-compact stands for: Meter run, Nominal pipe diameter DN40, Flange PN40 / facing B1 acc. EN 1092-1, Internal pipe diameter (Alf-Sensor standard) 38,30 mm, Bore 30,02 mm, Material 1.4404 = SS316L, Process fluid : steam, Compact connection to Parker make 3-valve manifold HEFS3, Special requirements: None,...