Air inlets
32Pages

{{requestButtons}}

Catalog excerpts

Air inlets - 1

AIR INLETS Gnral ■ Self-balanced ■ air inlets H umidi ty-controlled ■ air inlets Sleeves ■ AIR INLETS

Open the catalog to page 1
Air inlets - 2

Contents GENERAL p.3 Purpose of the air Inlet p.4 Regulatory environnent M Dfinition p.4 Dlmenslonlng p. 5 Installation _M SELF-BALANCED AIR INLETS p. 7 Slection tables P 8 Sell-balanced air Inlet - EMMA type p 10 Sell-balanced and acoustic air inlet - EA type P 12 Self-balanced and acoustic air Inlet - EAJ type p 14 Self-balanced and acoustic air Inlet - ELUA type p 16 Sleeves p 18 Accessories p 20 HUMIDITY-CONTROLLED AIR INLETS p. 21 S驩lection tables p. 22 Humidity-controIIed and acoustic air inlet - EHA type p. 21 Humidlty<ontrolled and acoustic air Inlet - EHB type p. 26 Sleeves p. 28...

Open the catalog to page 2
Air inlets - 3

General Purpose ol the air inlet p. 4 Regulalory environmenl p. 4 Dfinition p. 4 Dlmensioning p. 5 Installation p. 6

Open the catalog to page 3
Air inlets - 4

General PURPOSE OF THE AIR INLET French Standard NF P 50-411 (DTU 68.2) of May 1993, concer-ning CMEV installations. Օ French Standard NF XP 50-410 (DTU 68.1) of July 1995 concer-ning the design and dimensioning rules of CMEV installations. NFE 51-732, test specification concerning the characteristics necessary to verify the quality of the external wall air inlets. Acoustic requirements Օ French Decrees of 30.06.1999 (which replace and rescind the NRA, Decree of 28.10.1994) concerning the acoustic characteristics of residential housing and their methods of application. ͕ French Decree of...

Open the catalog to page 4
Air inlets - 5

■ Dimensioning_ Airflows The air inlets, plus the permeability of the building's envelop should make it possible to obtain the dwelling's total exhaust airflow, whether the CMEV system is a constant flow system (self-balanced CMEV) or with modulated airflows (humidity- controlled CMEV). Self-balanced CMEV Self-balanced air inlets : EMMA, EA, EAI, ELLIA. The requirements set by the XP P 50-410 (DTU 68.1) standard impose a maximum negative pressure of 20 Pa in the dwelling, which defines a typical dimensioning according to permeability values set in this standard. Gas heating Number of main...

Open the catalog to page 5
Air inlets - 6

General INSTALLATION Diffrent types of assembly Depending on the site dtails (type of ventilation, type of work) and after airflow and acoustic dimensioning of the air inlet, dif驭ferent types of installation are possible. The CMEV air inlet can be installed either by: - penetrating through window frames (PVC, wood or aluminium window frames, roof window ...), - penetration through the top of windows, - penetration through masonry, - penetration through a roller blind case. Installation in a roller blind casing Dimensions of standard slots The slots necessary for the installation of the air...

Open the catalog to page 6
Air inlets - 7

Self-balanced air inlets Slection tables p. 8 1. Installation on window frames 2. Installation on frames Self-balanced air inlet - EMMA type p. 10 1. Description 2. Technical characteristics 3. Airflow characteristics 4. Airflow selection 5. Installation on window frames 6. Product codes Self-balanced and acoustic air inlet - EA type p. 12 1. Description 2. Technical characteristics 3. Airflow characteristics 4. Acoustic characteristics 5. Installation on window frames 6. Product codes Self-balanced and acoustic air inlet - EAI type p. 14 1. Description 2. Technical characteristics...

Open the catalog to page 7
Air inlets - 8

Slection tables 1 - Installation on window frames (slection according to the airflow, the slot and the acoustic requirement) Airflow Slot(s) Non ESA 4 (AC 1) ESA 5 (ac 2) External wall 35 dB (m3/h) acoustic Dnew(Ctr) > 36 dB Dnew(Ctr) > 39 dB Dnew(Ctr) > 41 dB 45 PVC and Aluminium ( 1 ( 1 EMMA (33 dB) - - - i J i J Wood IMPOSSIBLE IN TERMS OF AERAULICS. PVC and Aluminium EMMA (33 dB) EA (38 dB) EA + spacer sleeve (39 dB) ELLIA (41 dB) 30 D C ELLIA (41 dB) Wood EMMA (33 dB) EAI (38 dB) EA PVC and Aluminium EMMA EA (40 dB) ELLIA 22 (33 dB) (40 dB) ELLIA (43 dB) (43 dB) Wood EMMA EAI EAI (33...

Open the catalog to page 8
Air inlets - 9

2 - Installation on frames (slection according to the airflow, the installation and the acoustic requirement) Airflow Instal- ESA 4(AC 1) ESA 5 (ac 2) External wall 35 dB External wall 38 dB External wall 42 dB (m3/h) lation Dnew(Ctr) > 36 dB Dnew(Ctr) > 39 dB Dnew(Ctr) > 41 dB Dnew(Ctr) > 44 dB Dnew(Ctr) > 46 dB Top HDF 52 x 50 Sleeve Sleeve of + EA 30 (37 dB) HDF 90 x 50 HDF chicane Window HDF 70 x 50 + EA 30 + EAI 30 sleeve + EA 30 (38 dB) (39 dB) (42 dB) Feed Straight female Female sleeve Z through sleeve + adapter + adapter unit wall unit + EA 30 (38 dB) + EA 30 (48 dB) Top Sleeve HDF...

Open the catalog to page 9
Air inlets - 10

Air inlet ■ EMMA type . DESCRIPTION \ non acoustic air inlet suitable for rnovation work. It adapts toall tvpesof slols and is used to meet ail airflow levels in a single product 2. TECHMCAL CHARACTERISTICS Type of slot airflow (ml/h) 22 30 45 250x15 Vs Yes No 2 x (172 x 12) Ya Vu Yes > * i * 3. AIRFLOW CHARACTERISTICS The airflow characteristics of the EMMA self-balnced air inlets modulus 22, 30 and 45 are in compliance with the NFE 51-732 standard defining the airflow -pressure range, which the air inlets must respect. se EMMA 22 + hood 22 - EMMA 30 # hood 30 [Soi 260x15) (Stol 2x(172x...

Open the catalog to page 10
Air inlets - 11

90 EMMA 45 * hood 30 - [SW 2 x (172 x 12)) «0 70 60 1" 30 m / / 10 ' 0 ^/1 1 J 20 30 40 ft 1 60 70 0 0 00 11 4. CHOICE OF AIRFLOW Modulus 22 : use EMMA as il is supplied. Modulus 30 : break the 3 central lugs (n: 2 and 3), Modulus 45 : break al) the lugs (nE 1.2 and 3). 5. INSTALLATION' ON WNDOW FRAMES KMMA*.STANDARDH*K>T> 30 -OnPV( window fr-iint s KMMA * SIANDARI) HOOD O (ta wrcxl uindm* faum* 6. PRODl'CT CODES Modulus Composition Colour and RAI (dB) (dm) Air Oulslde Whlte Brown ak Alu Black Ivory inlet hood 9003 8017 8001 7035 9005 1015 22 30 - EMMA ח 11510 11.513 11.514 11.511 11.512...

Open the catalog to page 11
Air inlets - 12

■ 1. DESCRIPTION \n acoustic air inlrt winch fils onto PVC or aluminium window (rames, with ahflows of 22 and 30 m3/h. 2. TECHMCAL CHARACTERISTICS type of slot airllow (m,h) 2 x (172x12) EA22 EA30 3. AIRFL0W: CHAR.\CTERISTICS The airflow characteristics ol the EA scH-balanced air inlets modulus 22, and 30 are in compliance with NFE 51-732 standard defining the airflow -pressure range, which the air Inlets must respect. Data taken f mm PV CET1AT French Test Laboratory Report N19680038.

Open the catalog to page 12

All Aldes catalogs and technical brochures

  1. Fire Dampers

    48 Pages

  2. Fire Protection

    176 Pages

  3. Air Diffusion

    270 Pages

Archived catalogs

  1. Axpirtech

    12 Pages

  2. Axpir range

    12 Pages