video corpo

Valves for hazardous areas
21Pages

{{requestButtons}}

Catalog excerpts

Valves for hazardous areas - 2

21 Series Exd & Exm 2/2 Normally Closed Engineered for life Features Out (2) Electrical Characteristics In (1) Flow Data • Compact Valve Design • Wide Range of Available Orices • Zero Pressure Rated • Choice of Valve Body Material and Seals • Exd and Exm Options • Choice of electrical connections • ATEX approved • Response time 5-25ms Features & Benets 10.1 Coil Voltage DC (=): 24v, 110v Coil Voltage AC 50Hz (~): 24v, 110v, 230v Voltage tolerance: +10% or -10% Duty Cycle: 100% ED Protection Class (Exd): Exd IIC T6 (-50°C to +40°C ) (IP67 BS EN 60529) Electrical Connection (Exd): M20 x...

Open the catalog to page 2
Valves for hazardous areas - 3

21 Series Exd & Exm 2/2 Normally Closed Engineered for life Note: · Tested in accordance with BS EN 12266-1 · PED Compliant Dimensions Solenoid Coil may be rotated to any angle. Options M20 X 1.5 Female Protection Class Electrical Entry Ambient EExd T4 (IP67) -50°C to +70°C Solenoid Enclosure See solenoid enclosures for specic details See corrosion reference guide and sealing solutions for material compatibility 10.1 EXD 0.9 Kg EXM 0.4 Kg Aluminium enclosure as standard Dimensions given in mm Stainless Steel 316 Body Material PTFE -200°C to +180°C Seal Material Media Temperature Range EPDM...

Open the catalog to page 3
Valves for hazardous areas - 5

ACD Series Exd & Exm 2/2 Normally Closed Seal Material Media Temperature Range EPDM (WRAS approved up to 1”) -50°C to +120°C Viton -20°C to +150°C See corrosion reference guide and sealing solutions for material compatibility Stainless Steel 316 Body Material Engineered for life Note: · Tested in accordance with BS EN 12266-1 · PED Compliant Dimensions Solenoid Coil may be rotated to any angle. Options See solenoid enclosures for specic details ANSI and PN ange connections available Mounting bracket option available Stainless steel valves above 1" refer to ACDLSS 10.2 Size A B C D 3/8" -...

Open the catalog to page 5
Valves for hazardous areas - 6

ACP Series Exd & Exm 2/2 Normally Closed Engineered for life Features Specications Electrical Characteristics Flow Data Out (2) In (1) Water Flow (L/Min) 2.2 10 Water Flow (GPM) 5 20 0.1 1 10 Pressure Drop (Bar) 80 160 1.5 3 5 10 15 Pressure Drop (PSI) ACP3 ACP4 ACP6 ACP7 ACP8-9 ACP10 100 1000 40 • Heavy Duty Valve Design • Piston Operation • Wide Temperature Range Capabilities • Choice of Valve Body Material and Seals • ATEX approved • Response time up to 1” 40-100ms • Response time up to 2” 60-1000ms Features & Benets 10.3 P.Max Orice Pipe Size Kv AC Voltages DC Voltages (Bar) mm Cat No....

Open the catalog to page 6
Valves for hazardous areas - 7

ACP Series Exd & Exm 2/2 Normally Closed EExd T6 (IP67) M20 X 1.5 Female M20 X 1.5 Female Protection Class Electrical Entry Ambient -50°C to +40°C -50°C to +70°C -20°C to +40°C EExd T4 (IP67) M16 X 1.5 Male FLYING LEAD Exm T5 (IP65) Solenoid Enclosure See corrosion reference guide and sealing solutions for material compatibility Stainless Steel 316 Body Material PTFE -200°C to +180°C Seal Material Media Temperature Range EPDM -50°C to +120°C Viton -20°C to +150°C Note: · Tested in accordance with BS EN 12266-1 · PED Compliant · Dimensions given in mm Solenoid Coil may be rotated to any...

Open the catalog to page 7
Valves for hazardous areas - 8

ACDLSS Series Exd & Exm 2/2 Normally Closed Engineered for life Features Specications Electrical Characteristics Flow Data Out (2) In (1) • Robust Valve Design • Diaphragm Operation • Fully Ported Orices for high Kv • Choice of Valve Body Material and Seals • Sizes 3/8” - 3/4” Advantica approved to BS EN 60730-2-8 for household use. • ATEX approved • Response time 60-150ms Features & Benets 10.4 10 100 1000 Water Flow L/Min Pressure Drop (Bar) 2.2 5 10 20 40 80 Water Flow GPM 160 1.5 3 5 10 15 Pressure drop ACDL8 ACDL9 ACDL10 ACDL11 ACDL12 P.Max Orice Pipe Size Kv AC Voltages DC Voltages...

Open the catalog to page 8
Valves for hazardous areas - 9

ACDLSS Series Exd & Exm 2/2 Normally Closed Engineered for life Note: · Tested in accordance with BS EN 12266-1 · PED Compliant Dimensions Solenoid Coil may be rotated to any angle. Options 10.4 B E A Size A B C D Weight (Exd) 1¼" 100 45 146 90 1½" 118 56.5 142 97 2" 137 70 153 117 2½" 172 89 157 143 3" 195 94 167 156 2.9Kg 3.0Kg 4.4Kg 5.7Kg 6.9Kg 90 97 117 143 156 E Weight (Exm) 2.6Kg 2.7Kg 4.2Kg 5.4Kg 6.7Kg D 66 110 EXD D EXM A 78 B C M20 x 1.5 Conduit Male Dimensions given in mm See solenoid enclosures for specic details See corrosion reference guide and sealing solutions for material...

Open the catalog to page 9
Valves for hazardous areas - 10

22 Series Exd & Exm 2/2 Normally Open Engineered for life Features Electrical Characteristics Flow Data Out (2) In (1) 0.1 1 10 .01 1 10 100 Water Flow (L/Min) Pressure Drop (Bar) 002 0.1 0.25 0.5 2.5 10 20 1.5 3 5 15 Pressure drop (PSI) 50 150 5 1.6mm orice 3.0mm orice 6.0mm orice 1 • Zero Pressure Rated • Ideal for In-Line System Service and Repair • Choice of Valve Body Material and Seals • Design accommodates for Exd and Exm options • Response time 5-25ms Features & Benets 10.5 EXD EXM Specications How to use Flow Chart 1. Select the required ow. 2. Note the corresponding Qn and...

Open the catalog to page 10
Valves for hazardous areas - 11

22 Series Exd & Exm 2/2 Normally Open Engineered for life Note: · Tested in accordance with BS EN 12266-1 · PED Compliant Dimensions Solenoid Coil may be rotated to any angle. Options Options EExd T6 (IP67) M20 X 1.5 Female M20 X 1.5 Female Protection Class Electrical Entry Ambient -50°C to +40°C -50°C to +70°C -20°C to +40°C EExd T4 (IP67) M16 X 1.5 Male FLYING LEAD Exm T5 (IP65) Solenoid Enclosure See solenoid enclosures for specic details CSA and IECEX options See corrosion reference guide and sealing solutions for material compatibility 10.5 EXD (0.85Kg) EXM (0.55Kg) Dimensions given in...

Open the catalog to page 11
Valves for hazardous areas - 12

ACDN Series Exd & Exm 2/2 Normally Open Engineered for life Electrical Characteristics Features Flow Data • Robust Valve Design • Diaphragm Operation • Fully Ported Orices for high Kv • Choice of Valve Body Material and Seals • Sizes 3/8” - 1” Advantica approved to BS EN 60730-2-8 for household use. • Response time up to 1” 15-60ms • Response time up to 2” 60-120ms Features & Benets Out (2) In (1) 10.6 EXD EXM Specications Water Flow (L/Min) 2.2 10 Water Flow (GPM) 5 20 0.1 1 10 Pressure Drop (Bar) 80 160 1.5 3 5 10 15 Pressure Drop (PSI) ACDN3 ACDN4 ACDN6 ACDN7 ACDN8-9 ACDN10 100 1000 40...

Open the catalog to page 12

All Alcon catalogs and technical brochures

  1. Valves for gas

    29 Pages