Vantex New low maintenance battery range data
1 / 16Pages

Catalog excerpts

Vantex New low maintenance battery range data - 2

Long life at high temperatures Vantex shows good endurance with excellent results, with both cell types exceeding by more than 4 times the endurance test of IEC 62259. > The battery performs reliably at temperatures of up to +40C (+104аF), and in extreme conditions to -40C and +70аC (-40F and +158аF). Vantex has a service life expectancy of 12 plus years at +40C (+104аF) and of 20 plus years at +20C (+68аF). It can never suffer from sudden deathђ owing to the total reliability of Ni-Cd electrochemistry.Additionally, M type cells achievemore than In off-shore oil and gas applications,...

Open the catalog to page 2
Vantex New low maintenance battery range data - 3

Only one top-up during life The Vantex design enables highly efficient gas recombination of more than 90% far beyond therequirements of IEC 62259 ֖ allowing very low gas emissions and water consumption. As a result, Vantex may require only one topping-up operation during its entire service life. Easy to handle The optimised design of Vantex includes several features to make transportation, installation and operation fast and easy.Up to six cells are configured in series and assembled in blocks to enable easy handling. As Vantex cells are always factory-filled with electrolyte, rapid...

Open the catalog to page 3
Vantex New low maintenance battery range data - 6

Vantex Capacity Height Width > Approx. Internal Cell type weight resistance* connection per cell bolt per pole C > 5 1 cell 2 cells 3 cells 4 cells 5 cells 6 cells Ah mm in mm in mm in mm in mm in mm in mm in mm in kg lb mOhm >

Open the catalog to page 6
Vantex New low maintenance battery range data - 7

Vantex Capacity Height Width > Approx. Internal Cell type weight resistance* connection per cell bolt per pole C > 5 1 cell 2 cells 3 cells 4 cells 5 cells 6 cells Ah mm in mm in mm in mm in mm in mm in mm in mm in kg lb mOhm >

Open the catalog to page 7
Vantex New low maintenance battery range data - 16

VTX 2.1 Edition : June 2008. Produced by Arthur Associates.Photo credits: Alcad, Alstom/Phillipe GUIGNARD, DigitalVision, Bob Fleumer, Photodisc. Data in this document are subject to change without notice and become contractual only after written confirmation by Alcad. Alcad LimitedSweden Telephone: +46 491 68 100 Facsimile: +46 491 68 110 Alcad Sales Offices United Kingdom Telephone: +44 1279 772 555 Facsimile: +44 1279 420 696 Middle East Telephone: +357 25 871 816 Facsimile: +357 25 343 542 Asia Telephone: +65 6 7484 486 Facsimile: +65 6 7484 639 USA Telephone: +1 203 234 8333 Facsimile:...

Open the catalog to page 16