HC P Range

HC P Range
1 / 27 PagesView full catalog

HC P Range

Product catalog summary
Overview: This document provides comprehensive information on Alcad nickel-cadmium batteries, focusing on the Single Cell Range, including LCE P and LBE P models. These batteries are renowned for their durability, long lifespan, and ability to withstand extreme conditions.
Key Features:
  • Operational temperature range from -20°C to +50°C, with short-term extremes from -50°C to +70°C.
  • Lifespan exceeding 25 years in many applications.
  • Resistance to high temperature aging, electrical abuse, shock, and vibration.
  • Simple maintenance and low installation and life-cycle costs.
Design Features:
  • Fully welded internal construction with steel components.
  • Strong polypropylene containers, with flame retardant options.
  • Flip-top flame arresting vents as standard.
Compliance and Support:
  • Manufactured to ISO 9001 standards.
  • Meets and exceeds IEC 60623 standards.
  • Developed in line with EN-50272-2 safety requirements.
  • Full recycling service available.
Battery Types:
  • L Type: Thick plates for long discharge periods, suitable for power backup and bulk energy storage.
  • M Type: Designed for mixed loads with discharge durations between 30 minutes to 3 hours.
  • H Type: Thin plates for high current over short periods, typically less than 30 minutes.
Performance Data: Detailed tables provide cell dimensions, internal resistance, and performance data for various models under different conditions.
Additional Information:
  • Battery layout and rack options are discussed.
  • Disposal and recycling processes are outlined.
  • Float-corrected data is provided for accurate battery sizing in standby power applications.
Specifications: Detailed specifications for various battery cell types, including HC and HB series, are provided. Each cell type is listed with its capacity (C5 Ah) and performance metrics across different time intervals, measured at a standard temperature of +20°C ± 5°C.
Procedures: Procedures for configuring battery layouts, including standard and crosswise connections, are outlined. Guidelines for calculating the number of cells per row and the number of rows based on installation area dimensions are provided, with examples for clarity.
Standards: The performance of fully charged cells is evaluated according to the IEC 60623 standard, with final voltages specified for different applications.
Recommendations: Recommendations for battery rack configurations, including single and double-tier racks, are given. The document advises specifying the battery type and preferred rack configuration when ordering to ensure proper provision of connectors.
Environmental Considerations: Alcad emphasizes environmental responsibility throughout the battery lifecycle, from design to recycling. The importance of recycling Ni-Cd batteries is highlighted, with contact information for Alcad's collection network provided.
Key Data from Tables: Tables provide performance data for each cell type, including available amperes at various time intervals and final voltages for different applications. Dimensions for battery racks and configurations for different cell types are also included.
See more

Catalog excerpts

HC P Range-1

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:49.00pt "Arial", sans-serif; } ALCAD

 Open the catalog to page 1
HC P Range-2

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:50.00pt "Arial", sans-serif; } .font4 { font:27.00pt "Tahoma", sans-serif; } ALCAD Sinal e Cell Ranae Alcad have nearly 100 years' exprience in the development and manufacture of pocket plate cells and batteries. Today, they offer the widest ranae of high quality nickel-cadmium batteries available throughout the world and this publication details the Single Cell ranges...

 Open the catalog to page 2
HC P Range-3

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:1.30pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:8.40pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:10.00pt "Arial", sans-serif; } .font7 { font:12.00pt "Arial", sans-serif; } .font8 { font:25.00pt "Arial", sans-serif; } .font9 { font:31.00pt "Arial", sans-serif; } Single Cell ALCAD ALCAD Contents Construction features 4 LE range Cell...

 Open the catalog to page 3
HC P Range-4

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial", sans-serif; } .font4 { font:25.00pt "Arial", sans-serif; } Single Cell Construction features Connector cover_ In line with EN 50272-2 (safety) with IP2 level. . Flame-arresting vent -Terminal seal Plate group bus- Connects the plate tabs with the terminal post. Plate tabs and terminal posts are projection welded to the plate group bus. This is mechanically...

 Open the catalog to page 4
HC P Range-21

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:12.00pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } Battery layout Standard layouts Alcad has developed a sries of standard layouts by which a battery may be ordered. Whether the battery is being installed on a rack, in a cabinet or is simply free-standing,...

 Open the catalog to page 21
HC P Range-22

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:17.00pt "Arial", sans-serif; } Battery layout Assembly method Whatever your installation, use these simple guidelines when calculating your preferred configuration. 1. From the data in this publication, define the total number of cells in the battery. 2. Divide the length of the...

 Open the catalog to page 22
HC P Range-23

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:16.00pt "Arial", sans-serif; } Battery racks Alcad's product portfolio includes standard and anti-seismic battery racks (conforming to Uniform Building Code, Seismic Zone 4). These have been designed for all cell types in the Alcad range and are supplied unassembled to allow for easy installation. The purpose-built racks are strong, adaptable and provide good alkali...

 Open the catalog to page 23
HC P Range-25

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:1.30pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:8.40pt "Arial", sans-serif; } .font5 { font:17.00pt "Arial", sans-serif; } Battery racks Diagram 5. 1 tier, 4 steps, normal connection 2 tier, 4 steps, normal connection 1 11 11 11 1 u Diagram 7. 1 tier, 2 steps, crosswise connection 2 tier, 2 steps, crosswise connection 3-1_ i D | Diagram 9. 1 tier, 1 step, crosswise connection...

 Open the catalog to page 25
HC P Range-26

2815_AlcadS2.7AW.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:17.00pt "Arial", sans-serif; } Disposai and recycling In a world where autonomous sources of electric power are ever more in demand, Alcad batteries provide an environmentally responsible answer to these needs. Environmental management lies at the core of Alcad's business and we take care to control every stage of a battery's life-cycle in terms of potential impact. Environmental protection is our top priority, from design and production through end-of-life...

 Open the catalog to page 26
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.