j^Wiight International u ^ SU190 Double Pole Single Throw Normally Open (Part of the SU Series) The SU190 is an up-rated variant of the SW190 Series of contactor primarily designed to switch heavy duty D.C. loads, however it is also capable of switching A.C. loads. The SU190 is suitable for switching Resistive, Capacitive and Inductive loads. Typical applications include electric motors, hydraulic power packs, winches, speed controllers and Power Distribution Systems. Interrupted current - opening and closing on load with frequent switching (results in increased contact resistance). Interrupted Uninterrupted Thermal Current Rating (^h) Intermittent Current Rating: 30% Duty 40% Duty 50% Duty 60% Duty 70% Duty Rated Fault Current Breaking Capacity ^cn) 5ms Time Constant: (in accordance with UL583*) Rated Fault Current Breaking Capacity ('cn) Resistive Load: (in accordance with UL508*) • Uninterrupted current - no or infrequent load switching requirements (maintains a lower contact resistance). The contactors feature double pole, double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The SU190 is easy to install, with M5 tapped holes in the switch frame or a variety of optional brackets available. Electrical connections follow industry standards, with M10 main terminal studs and an option for either 6.3mm standard spade terminals or flying leads on the coil assembly. Mounting can be vertical or horizontal, when vertical the M10 contact studs should point upwards. If the requirement is for downwards orientation we can adjust the contactor to compensate for this. Maximum Recommended Contact Voltages (Ue): (Both Poles in same circuit) 96V D.C. 250V D.C. 40mV >3 x 106 Cycles From 6 to 240V A.C./D.C. SU190 SU190B Typical Voltage Drop per pole across New Contacts at 250A Mechanical Durability Coil Voltage Available (Us) (Rectifier board required for A.C.) Coil Power Dissipation: Highly Intermittent Rated Types Intermittently Rated types Prolonged Rated Types Continuously Rated Types Maximum Pull-In Voltage (Coil at 20° C) Guideline: 60% U Highly Intermittent Rated types ^ (Max 25% Duty Cycle) Intermittently Rated types W (Max 70% Duty Cycle) Prolonged Operation W (Max 90% Duty Cycle) Continuously Rated Types W Drop-Out Voltage Range Typical Pull-In Time Typical Drop-Out Time (N/O Contacts to Open): Without Suppression With Diode Suppression With Diode and Resistor (Subject to resistance value) Typical Contact Bounce Period Operating Ambient Temperature Guideline Contactor Weight: SU190 With Blowouts Advised Connection Sizes for Maximum Continuous Current M5 MOUNTING HOLES (4 OFF PER SIDE) Current (Amperes) Contact Performance Key: - Interrupted Current - Uninterrupted Current Copper busbar Cable ^ Rated suitable for Application^ Note: Where applicable values shown are at 20°C * Please check our web site for product UL status • Performance data provided should be used as a guide only. Some de-rating or variation from figures may be necessary according to application. • Thermal current ratings stated are dependant upon the size of conductor being used • For further technical advice email: [email protected] • Albright reserve the right to change data without prior notice Connection Diagram TO BE TIGHTENED WITHIN RANGE 13.4 - 14.6Nm Alaright Int25national Ltd, Evingar Trading Estate, A7dglen Road, Whitchurch, Hampshi3e, RG28 7BB, UK Tel: +44 (0)12b6 8930(50, Fax: +44 (0)1215(5 893562, Dedicated Seles Tel: +44 (0)1256 89e030, Fax: +44 (0)1256 890043 E-mail: [email protected] or [email protected] Web Site: www.albrightinternational.com Copyright © 2020 Albright International LTD
Open the catalog to page 12 Pages
1 Page
1 Page
1 Page
7 Pages
1 Page