Isolated Power Systems Medical Solutions IG | IT | MED Series
Open the catalog to page 1
Isolated Power Supply Panels Isolated power panels are used in Group 2 rooms in medical locations, and they consist of auxiliary devices and test combinations such as isolating transformer, insulation monitoring device and insulation fault location devices. IT system different from TN and TT systems, when an insulation failure occurs, IT system ensures that there is no electrical problem by preventing the circuit breakers from tripping and interrupting the system. The medical equipment continues to function, the fault currents are reduced to non-critical values, and the energy interruption...
Open the catalog to page 2
Isolating Transformers IT series medical isolating transformers are manufactured in accordance with IEC 603647-710 and IEC 61558-2-15 standards. IT isolating transformers are used to supply power at Group 2 rooms of medical locations such as operating rooms, intensive care units and as addition they are also used to power laboratory instruments and other sensitive devices. The design of the isolating transformers is aimed at reducing the impact of electrical faults through electrostatic protection. The IT series medical isolating transformers have galvanically isolated windings to minimize...
Open the catalog to page 4
IMD 30 Insulation Monitoring Device IMD 30 Insulation Monitoring Device is one of the most important equipment of IT grounding systems. It detects insulation fault in the system by constantly checking the insulation resistance level between phases and earth. At the same time, it monitors the load current and the temperature of the isolating transformer in accordance with the IEC 60364-7-710 standard and ensures that the warning system is started when it reaches critical values. The device, which can indicate alarm situations visually and audibly, has the feature of showing insulation fault,...
Open the catalog to page 5
CTS 30 Changeover Module is the equipment that enables to select the convenient one between two different sources supplying the isolated power panel and transfer it to the output. The changeover module, which performs the transfer process within the periods specified by the IEC 60364-7-710 standard, monitors the continuous voltages of the two sources and automatically transfers when the voltage value drops below 0,9xUn and exceeds 1,15xUn. Thus, any power interruption that may occur from the failure of the supply source or from the supply cables is prevented. Advantages • Transfer Time: <...
Open the catalog to page 6
LAP 70 Local Alarm Panel RAI 70 Remote Alam Indicator LAP 70 Local Alarm Panel indicates alarms like insulation fault, overcurrent, transformer over temperature visually and audibly that are detected by the IMD 30 Insulation Monitoring Device and stores each event with their timestamp. Advantages • Automatic adressing thanks to synchronization with IMD 30 • Up to 150 event logs thanks to its internal real time clock. • Remote insulation test and fault contact outputs The RAI 70 Remote Alarm Indicator enables remote monitoring of all data, alarms, and events in the isolated power system...
Open the catalog to page 7
HMI 70 Hospital Monitoring Interface , ten* S’* oes«,raCS i____OJ HMI 70 Hospital Monitoring Interface is used to remotely monitor all alarm information detected by the medical isolated power system. HMI 70 Hospital Monitoring Interface communicates with RAI 70 Remote Alarm Panel and IG Series Medical Isolated Power Panel, allowing the technical service personnel in the hospital to monitor transfer alarm, insulation fault, overtemperature fault and overload fault information audibly and visually through a single product. Advantages • Monitoring the entire system on a single screen •...
Open the catalog to page 8
Doc. Nr: MED-20240320/Eng Owing to periodical improvements of our products the supplied products may differ in some details from the data stated in the prospectus material. Published by Aktif Data subject to alteration without notice. Design & Creation: Aktif / Photos: Aktif - Stock.xchng & Shutterstock, Published Date: 20.03.2024 Germany Office Bayraktar Bul. Şehit Sk. No: 5 34775 Ümraniye, İstanbul, TR Phone : +90 (216) 314 93 20 Fax : +90 (216) 314 93 60 www.aktif.net - info@aktif.net Bahnhofstrasse 82-86 35390 Giessen, Germany Phone : +49 176 60940534 www.aktif.net info.de@aktif.net...
Open the catalog to page 9All Aktif Muhendislik Dis Tic. AS. catalogs and technical brochures
-
Ring Main Units
4 Pages
-
Neutral Grounding Solutions
4 Pages
-
Load Banks
4 Pages
-
Filter Resistors
4 Pages
-
Operating Room Control Panel
4 Pages
-
Traction Power System Solutions
12 Pages
-
Coil Winding Machines
3 Pages
-
LV Panel
4 Pages
-
F-SERIE
2 Pages
-
D-SERIE
2 Pages
-
C-SERIE
2 Pages
-
s-SERIE
2 Pages
-
Compact Substations E-House
6 Pages
-
Metal Enclosed Switchgears
4 Pages
-
Metal Clad Switchgears
4 Pages
-
Mobile Substations
4 Pages