Catalog excerpts

Compact Substations E-House
Open the catalog to page 1
SCK type are manufactured as Compact Substations for Power Distribution and as E-houses for Oil & Gas Applications in compliance with Zone2 Hazardous Area Classification, as according to IEC 62271-202 and equipped with special operating and safety systems. SCK series can be manufactured with three different materials depending on the application. Material Data SCK-1 : Steel sheet SCK-2 : Sandwich Panel SCK-3 : Container SCK series offer segregated design for MV Switchgear, LV Switchgear, Transformer, Emergency Supply and Batteries with dimensions and specifications as according to the...
Open the catalog to page 2
Design Compact Substations can be designed in accordance with requirement of project. Equipment in Compact Substations can be provided as ex-proof. Dimension Dimensions of Compact Substation can be designed in accordance with requirement of project and are specified in view of the fact that rooms, dimensions of switching equipment, operating conditions and operating area Base Base are made of NPU or NPI shapes according to load on the floor and NPU and NPI shapes are covered hot dip galvanized. Frame Frame of Compact Substation is made of 5 mm Sil St-37 and covered with hot dip galvanized...
Open the catalog to page 3
Compact Substation, E-House Technical Specifications Interior Lighting, External Lighting All rooms in Compact Substation are equipped Lighting System in compliance with standards. Internal and external lighting equipment and sockets can be selected in compliance with Atex certificated for Zone2 Hazardous Area. Emergency Lighting Emergency Exit Armatures are installed on the way of thedoors. Emergency Exit Armatures include emergency lighting unit. Earthing Electrical devices are connected to an isolated earthing busbar. Separate earthing system is used for doors, base, walls and roof to...
Open the catalog to page 4
MV Switchgear Room In Medium Voltage (MV) Switchgear room, Metal Enclosed, Metal Clad, primary and secondary gas insulated switchgear (GIS and RMU) can be used. MV room dimensions are specified in according with equipment dimensions of the room. Transformer Room In Transformer room, dry type transformer and oil type transformer can be used. Dimensions of transformer room are specified in according with power of transformer. LV Switchgear Room In Low Voltage (LV) room, MCC distribution panel, AC distribution panel, DC distribution panel, metering panel, compensation panel, HVAC panel, fire...
Open the catalog to page 5
Doc. Nr: SCK-20230321/Eng Owing to periodical improvements of our products the supplied products may differ in some details from the data stated in the prospectus material. Published by Aktif Data subject to alteration without notice. Design & Creation: Aktif / Photos: Aktif - Stock.xchng & Shutterstock, Published Date: 21.03.2023 Germany Office Bayraktar Bul. Şehit Sk. No: 5 34775 Ümraniye, İstanbul, TR Phone : +90 (216) 314 93 20 Fax : +90 (216) 314 93 60 www.aktif.net - info@aktif.net Bahnhofstrasse 82-86 35390 Giessen, Germany Phone : +49 176 60940534 www.aktif.net info.de@aktif.net...
Open the catalog to page 6All Aktif Muhendislik Dis Tic. AS. catalogs and technical brochures
-
Ring Main Units
4 Pages
-
Neutral Grounding Solutions
4 Pages
-
Load Banks
4 Pages
-
Filter Resistors
4 Pages
-
Isolated Power Systems
9 Pages
-
Operating Room Control Panel
4 Pages
-
Traction Power System Solutions
12 Pages
-
Coil Winding Machines
3 Pages
-
LV Panel
4 Pages
-
F-SERIE
2 Pages
-
D-SERIE
2 Pages
-
C-SERIE
2 Pages
-
s-SERIE
2 Pages
-
Metal Enclosed Switchgears
4 Pages
-
Metal Clad Switchgears
4 Pages
-
Mobile Substations
4 Pages