Series REF-14 Technical details Series REF-10 and REF-14 Temperature range Filtered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, in each case free of aggressive additives. Alternative the pressure dew point has to be at least 10°C below deepest occurring ambient temperature. Materials Protection Body: Al (anodized), brass, stainless steel, zinc coated steel, plastic, Seals: NBR IP 65 according to EN 60529 modular valve-terminal for pneumatic control systems flexible and extendable terminal up to 24 stations valve sizes 14 mm width outlet ports of the valve Lateral mounting with mounting screws or on DIN Rail Multi-pin and IO Link available optionally: ▪ internal or external pilot port ▪ adapter plate for additional operating port ▪ pressure dividing plate in air channel 1, 3 and 5 or only in channel 1 ▪ seperate suitable pressure zones Technical data Number of stations electrical Connection Power consumption max. 1,3 W solenoid, electronic according version Flow rate up to 600 Nl/min (depending on valve type*) Pneumatical ports 1, 3 and 5 G1/4, E1 (external pilot port) and 82/87 (solenoid exhausts) M7 Operating ports Operating pressure Pilot pressure depending on valve type* depending on valve type* * see page 10 More detailled installation information see manuals at www.airtec.d
Open the catalog to page 1Series REF-14 Order code REF-01-*****-**-**-* Series Additional options - Version of the configurator Basic configuration consisting of: pressure input module, electrical module, manifold for valves, end plates, (optional) pressure dividing plates and additional pressure input modules mounted with: valves and (optional) blind plates electrical connection cable enclosed other options sintered bronze silencers plastic silencers silencers made of LDPE, sintered tube connection Ø 4 at 2 and 4 tube connection Ø 8 at 1 tube connection Ø 4 at 2 and 4 tube connection Ø 10 at 1 tube connection Ø 6...
Open the catalog to page 2pressure supply module pressure supply module electrical connecting module Voltage- and pressure zones Up to 3 seperate suitable voltage zones for emergency stops, voltage switch off´s operated by separation- or powermodule. Changing from internal to external pilot pressure Internal pilot pressure: - plug on pilot pressure port External pilot pressure: - plug displaced to port 1 - pilot port with M7 push in fitting
Open the catalog to page 3Series REF-14 Modular platform D F Electrical modules Pneumatical modules Pressure input module, upside Manifold for 14 mm valves, outlet ports lateral End plate, right, with additional pressure input Pressure dividing plate
Open the catalog to page 4Series REF-14 Dimensions of modules Pressure input modules, upside REFI-01-01 Standard module Module for pressure separation REFI-02-01 Module for additional air supply REFI-03-01 End module for additional air supply For external pilot pressure version please remove the plug from port E1 to port 1. (see page 2) The module model number changes from REFI to REFE. Manifolds for valves, outlet ports lateral REF-14S-xx-01 xx = n= 03, 04, 05, 06, 08, 10, 12 (By combining single subbases 3 - 24 stations possible.)
Open the catalog to page 6Series REF-14 Dimensions of modules End plates REF-EPL-01 End plate, right, with additional pressure input REF-EPR-02 Electrical modules REF-M25-01 Multi-pin, Sub-D 25-pin
Open the catalog to page 7Series REF-14 Electrical options Multi-pin, Sub-D 25-pin, up to 12 stations The 25-pin multi plug has to be ordered separately. Pin Wire colour Wire colour valve 7 / solenoid 14 (bottom) valve 1 / solenoid 2 (bottom) brown/ green white/ yellow valve 8 / solenoid 16 (bottom) yellow/ brown valve 2 / solenoid 4 (bottom) white/ grey valve 9 / solenoid 18 (bottom) grey/ brown valve 3 / solenoid 6 (bottom) white/ pink valve 10 / solenoid 20 (bottom) pink/ brown valve 4 / solenoid 8 (bottom) valve 5 / solenoid 10 (bottom) valve 6 / solenoid 12 (bottom) white/ blue valve 11 / solenoid 22 (bottom)...
Open the catalog to page 8Series REF-14 Electrical options IO-Link IO-Link connector IO-Link version Baud rate 24 V DC ± 10%, 2 galvanically isolated power circuits for IO-Link electronic (US) bzw solenoids (UA) open-circuit: ca. 170 mA full load: max. 2,4 A, depending on number of active valves Power consumption Min. cycle time (device)
Open the catalog to page 9Valve terminals > valves > Series REF-14 Technical data Outlets according to the pneumatical connections of the terminal Temperature range Filtered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10°C below lowest occurring ambient temperature. Body: Al (anodized), plastic, seals: NBR, inner parts: Al, steel, brass and plastic Nominal voltage Power consumption 1.3 W Protection Electrically operated spool valve. The manual override is detent. The manual override...
Open the catalog to page 10Valve terminals > valves > Valve terminals Technical data Model-no.: Internal pilot pressure Operating pressure (bar) 2,5 ... 8 External pilot pressure Operating pressure (bar) 2 ... 8 Flow rate (Nl/min) Internal pilot pressure Operating pressure (bar) 3 ... 8 External pilot pressure Operating pressure (bar) 0 ... 8 Pilot pressure (bar) Flow rate (Nl/min)
Open the catalog to page 11Valve terminals > valves > Series REF-14 Accessories Model-no.: REF-10-VP-01 Blind plate for valve and coil station REF-14-AP-01 Blind plate for valve and coil station with 3 ports G1/8 for additional air supply (inlet and exhaust) 28-ST-46-M1-yy-xxx 25- or 44-pin multi plug, straight REF-DT-01 Pressure dividing plug suitable in channel 1,3 and 5
Open the catalog to page 12All AIRTEC Pneumatic catalogs and technical brochures
-
Mechanically operated valves
21 Pages
-
Series E-25
2 Pages
-
Series L-25
2 Pages
-
Series M-04
14 Pages
-
Series SU
1 Pages
-
Series 84-4F
1 Pages
-
Series 84-4HF, 84-4HR
2 Pages
-
Series TK-28
1 Pages
-
Series ST-18
1 Pages
-
Series T-25
5 Pages
-
Series HF
1 Pages
-
Series HV
1 Pages
-
Series RE-04
3 Pages
-
Series RE-19
4 Pages
-
Series ICKN-55
4 Pages
-
Series KNX-55
4 Pages
-
Series PNX-55
2 Pages
-
Series M-07
10 Pages
-
Series BP-01 and BP-02
3 Pages
-
Series E-28
1 Pages
-
basic line Valves and Cylinders
62 Pages
-
T series
12 Pages
-
HF series
2 Pages
-
ER series
1 Pages
-
EL series
1 Pages
-
E series
2 Pages
-
Hand lever valves
2 Pages
-
ST series
1 Pages
-
F series
1 Pages
-
AIRTEC_System_IMA_EN
8 Pages
-
54-ATEX-03rev08
1 Pages
-
54-ATEX-02rev06_111206
5 Pages
-
54-SIL-02rev05
1 Pages
-
54-SIL-02_rev06_120612
1 Pages
-
GB RE-44
5 Pages
-
54-Produkte-01_111216(1)
2 Pages
-
AIRTEC Classic ejectors
3 Pages
-
Roller-operated valves
2 Pages
-
Stem-operated valves
2 Pages
Archived catalogs
-
Series XG cylinder
13 Pages
-
standard cylinder
19 Pages
-
AIRTEC Column ejectors
32 Pages
-
AIRTEC Central ejectors
20 Pages