Catalog excerpts
Technical details Valves > electrically operated valves > Electrically operated spool valve. The manual override is detent and is operated by screw driver. M-07-310-HN-xxx 3/2-way, single solenoid, air spring return, NC MO-07-310-HN-xxx 3/2-way, single solenoid, air spring return, No M-07-311-HN-xxx 3/2-way, single solenoid, mechanical spring return, NC MO-07-311-HN-xxx 3/2-way, single solenoid, mechanical spring return, NO ME-07-311-HN-xxx 3/2-way, single solenoid, external pilot pressure, mechanical spring return M-07-320-HN-xxx 3/2-way, double solenoid ME-07-320-HN-xxx 3/2-way, double solenoid, external pilot pressure Please complete: xxx = electrical option M-07-510-HN-xxx 5/2-way, single solenoid, air spring return M-07-511-HN-xxx 5/2-way, single solenoid, mechanical spring return ME-07-511-HN-xxx 5/2-way, single solenoid, external pilot pressure, mechanical spring return M-07-520-HN-xxx 5/2-way, double solenoid ME-07-520-HN-xxx 5/2-way, double solenoid, external pilot pressure M-07-530-HN-xxx 5/3-way, center position closed M-07-532-HN-xxx 5/3-way, center position safety M-07-533-HN-xxx 5/3-way, center position exhausted M-07-534-HN-xxx 5/3-way, center position pressurized Electrical options -xxx Manual override on same side of ports Nominal voltage Power consumption Specifics Plug connection*1 2 or 2 and 4 1, 3 or 1, 3 and 5 12 V DC 4.2 W Form B industrial norm -441 -411 12 V DC 2.2 W max. 8 bar Form B industrial norm -461 -431 24 V DC 4.2 W Form B industrial norm -442 -412 24 V DC 2.2 W max. 8 bar Form B industrial norm -462 -432 24 V AC 7/4 VA Form B industrial norm -452 -422 115 V AC 7/4 VA Form B industrial norm -456 -426 230 V AC 7/4 VA Form B industrial norm -457 -427 *1Plug socket not included, suitable plug sockets see page 5.
Open the catalog to page 1Valves > electrically operated valves > Technical data Model-no.: Operating pressure* (bar) Pilot pressure* (bar) Flow rate (Nl/min) Response time (ms) at 6 bar Weight (kg) Model-no.: Operating pressure* (bar) Pilot pressure* (bar) Flow rate (Nl/min) Response time (ms) at 6 bar Weight (kg) Model-no.: Operating pressure* (bar) Pilot pressure* (bar) Flow rate (Nl/min) Response time (ms) at 6 bar
Open the catalog to page 2Valves > electrically operated valves > *For the NO version MO-07 the ports 1 and 3 are inverted. 1 = pressure inlet 2,4 = outlets 3,5 = exhausts 6 = external pilot pressure supply (only at ME-valves) Plug socket (not included in scope of delivery) can be repositioned by 180°. Solenoid coil can be repositioned by 4 x 90°.
Open the catalog to page 3Valves > electrically operated valves > accessories > General information The R-141/n manifold is suitable for the M-07 valve series. As well available are blind plates R-141-V for blank stations and mounting brackets R-141-W (pair). Hollow bolts and gaskets are included. The manifold is as well suitable for the pneumatically operated valve series P-07.
Open the catalog to page 4Valves > electrically operated valves > accessories > Plug sockets Overall width Overall width Form B industrial norm Overall width Status indicator Protective circuit Connecting cable Wire cross section 0 Connecting cable yes no without max. 1.5 mm2 6 - 8 mm yes no without max. 1.5 mm2 6 - 8 mm yes yes (varistor) without max. 1.5 mm2 6 - 8 mm yes yes (varistor) without max. 1.5 mm2 6 - 8 mm yes yes (varistor) 3 m 3 x 0.75 mm2 yes yes (varistor) 3 m 3 x 0.75 mm2 * These plug sockets are fitted with integrated flat gaskets.
Open the catalog to page 5Valves > electrically operated valves > accessories > Plug sockets Dimensions Form A according to DIN EN 175301-803 M-04-310-HN, MO-04-310-HN 18 Form B industrial norm 5.5 Electrically circuits Status indicator (LED) Status indicator (LED) and protective circuit (varistor)
Open the catalog to page 6Valves > electrically operated valves > spare parts > Solenoid coils Overall width * The max. applicable operating temperature, depends on the temperature specification of the used valve. Overall width * The max. applicable operating temperature, depends on the temperature specification of the used valve.
Open the catalog to page 7Valves > electrically operated valves > spare parts > Solenoid coils Form B industrial norm Overall width * The max. applicable operating temperature, depends on the temperature specification of the used valve. Overall width Contact distance Contacts Protection Duty cycle Temperature range* Voltage tolerance For use with series * The max. applicable operating temperature, depends on the temperature specification of the used valve. 22 mm 2P IP 65 according to EN 60529 with connected plug socket 100 % -20°C ... +50°C ± 10 % Voltage Power consumption DC Power consumption AC Min. mounting...
Open the catalog to page 8Valves > electrically operated valves > spare parts > Solenoid coils Dimensions Form A according to DIN EN 175301-803 M-04-310-HN, MO-04-310-HN 35.5 Ø9.1 Form B industrial norm
Open the catalog to page 9Valves > electrically operated valves > technical information > Voltage code - HN * - * * * Manual override HN detent HNR detent HNT non-detent Coiland plug options Coil type ~1 Manual override position on side of ATEX 2GD, encapsulated with casting compound width 30 mm with coil and plug with coil, without plug without coil without pilot valve with coil, with enhanced humidity resistance, without plug with coil, with enhanced humidity resistance, with plug according to valve no no according to valve according to valve without indication ports 1/3/(5) DC ports 1/3/(5) AC ports 1/3/(5) DC,...
Open the catalog to page 10All AIRTEC Pneumatic catalogs and technical brochures
-
Mechanically operated valves
21 Pages
-
Series REF-14
12 Pages
-
Series E-25
2 Pages
-
Series L-25
2 Pages
-
Series M-04
14 Pages
-
Series SU
1 Pages
-
Series 84-4F
1 Pages
-
Series 84-4HF, 84-4HR
2 Pages
-
Series TK-28
1 Pages
-
Series ST-18
1 Pages
-
Series T-25
5 Pages
-
Series HF
1 Pages
-
Series HV
1 Pages
-
Series RE-04
3 Pages
-
Series RE-19
4 Pages
-
Series ICKN-55
4 Pages
-
Series KNX-55
4 Pages
-
Series PNX-55
2 Pages
-
Series BP-01 and BP-02
3 Pages
-
Series E-28
1 Pages
-
basic line Valves and Cylinders
62 Pages
-
T series
12 Pages
-
HF series
2 Pages
-
ER series
1 Pages
-
EL series
1 Pages
-
E series
2 Pages
-
Hand lever valves
2 Pages
-
ST series
1 Pages
-
F series
1 Pages
-
AIRTEC_System_IMA_EN
8 Pages
-
54-ATEX-03rev08
1 Pages
-
54-ATEX-02rev06_111206
5 Pages
-
54-SIL-02rev05
1 Pages
-
54-SIL-02_rev06_120612
1 Pages
-
GB RE-44
5 Pages
-
54-Produkte-01_111216(1)
2 Pages
-
AIRTEC Classic ejectors
3 Pages
-
Roller-operated valves
2 Pages
-
Stem-operated valves
2 Pages
Archived catalogs
-
Series XG cylinder
13 Pages
-
standard cylinder
19 Pages
-
AIRTEC Column ejectors
32 Pages
-
AIRTEC Central ejectors
20 Pages