GasEyeTM single and multigas cross duct analyzer
6Pages

{{requestButtons}}

Catalog excerpts

GasEyeTM single and multigas cross duct analyzer - 1

GasEyeTM analyzer looks deeply into your process GasEyeTM single and multigas cross duct analyzer TDLS - Tunable Diode Laser Spectometer

Open the catalog to page 1
GasEyeTM single and multigas cross duct analyzer - 2

Cables for industrial protocols1 Laser cables with plug GasEyeTM Cross Duct SG Single gauge analyzer Loop cable Ethernet cable Not a part of the GasEye system. Must be provided by the customer. Ethernet cable Receiver unit Loop cable Central unit Customer cable Transmitter unit Not a part of the GasEye system. Must be provided by the customer. Receiver unit Customer cable Central unit with transmitter GasEyeTM Cross Duct MG Multi gauge analyzer GasEyeTM Cross Duct MG MP Multi gauge multi point display with status indicators, power indicator,4 cable glands, Ethernet socket, purging fittings 1...

Open the catalog to page 2
GasEyeTM single and multigas cross duct analyzer - 3

LOD or 1% of the measured value, whichever is larger LOD or 2% of the measured value, whichever is larger ZERO DRIFT AND SPAN DRIFT WARM-UP TIME: MINIMUM RESPONSE TIME (T90) 0.7 - 2.0 barA up to 40 barg special application MAXIMUM PATH LENGTH POWER CONSUMPTION CLIMATIC CONDITIONS AMBIENT TEMPERATURE AMBIENT PRESSURE AMBIENT HUMIDITY PROCESS PURGE FLOW RATES SENSOR PURGE FLOW RATES 4 x analog output 4 – 20 mA (gas concentration, process transmission, 2 x AUX) – easy user selection via DIP switch between active/passive mode 8 x digital output 4 x analog input 4 – 20 mA (process temperature...

Open the catalog to page 3
GasEyeTM single and multigas cross duct analyzer - 4

A DDITION AL BUI LD - I N FEA T U R ES AUTOMATIC GAIN CONTROL (AGC) AGC ensures correct gas measurement even at high dust loads resulting in loss of optical transmission down to 0.5%. AGC operates fully automatic with no need for manual adjustment of the signal gain under any process conditions. SELF-CALIBRATION FEATURES internal reference gas compartment is used for closed loop control of the zero and span drift S AFETY LOW VOLTAGE DIRECTIVE (LVD) 2014/35/EU ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (EMC) 2014/30/UE QPS CERTIFICATION Certificate No. LR3167-1 ATEX DIRECTIVE 2014/34/EU...

Open the catalog to page 4
GasEyeTM single and multigas cross duct analyzer - 5

GasEyeTM Cross Duct GasEyeTM Cross Duct is a single or multi-laser analyzer that utilizes tunable diode laser (TDL) absorption spectroscopy. The central unit sends a laser light through the process which is detected by the receiver unit mounted on the opposite side of the process. When a gas of interest is present in this process, it will absorb the laser light. The optical power detected in the receiver unit will depend on the concentration of the gas, temperature, pressure, and optical pathlength according to Beer-Lambert law. In the GasEyeTM Cross Duct analyzer, the laser wavelength is...

Open the catalog to page 5
GasEyeTM single and multigas cross duct analyzer - 6

Application fields POWER/CEMENT/ INCINERATION PLANTS Combustion optimization CO/O2/CH4/H2O DENOX (SCNR + SCR ) NO/NO2/NOx/NH3/H2O DESOX (WET + SEMI DRY) SO2/HCL/HF/O2/H2O GasEyeTM Extractive 19” rack PRODUCTION/ STORAGE/ TRANSPORTATION OF NG, LNG, H2 H2 /HC/CO2/H2O/H2S PSA HCOOH/HCHO/NH3 CO/CO2/CH4 H2O/H2S + CO/H2 GasEyeTM Extractive wall mounted cabinet IP66 REFINERY & PETROCHEMICAL Hydrogen recycle Acetylene converter Catalytic reforming Cracking, flaring Ethylene production Sulfur recovery unit Olefins CHEMICAL PLANTS Acid plant SO3/SO2 Chlorine dryer H2O in chlorine Fertilizers plant...

Open the catalog to page 6