A10 PSM - 1

“It’s the small things that count.” See the smallest particles! Study and monitor particles smaller than the detection threshold of any CPC. Airmodus Particle Size Magnifier A10 grows nano sized aerosol particles into sizes that can be detected with a standard CPC. Particles as small as 1 nm can be counted. For a complete nanoparticle counting system — an nCNC system — please ask for the Airmodus A11. The A11 combines the A10 PSM with the Airmodus A20 CPC and an easy to use operating software. Benefits of the A10 - Detect particles as small as 1 nm in diameter in real time - Also the electrically neutral particles - Detect nucleation in-situ as it happens - Study the formation and growth of 1-4 nm particles - Use the activation spectrum for information of size or composition of the sampled particles Three operation modes - Fixed mode: One fixed cut-off* for monitoring the appearance of nanoparticles. - Stepping mode: Steps through several user-defined cut-offs*. Use to observe pre-defined size classes. - Scanning mode: scans through the operation range in less than 5 minutes, giving the activation spectrum of 1 – 4 nm* particles The A10 PSM is calibrated with nickel chromium nanoparticles. Based on the calibration, you can easily adjust your system for a particular nickel chromium equivalent cut-off diameter using the PSM management software. The possible equivalent 50% cut-off diameters range from 1 to 4 nm. Several researchers share their expertize with the PSM User Community. You are welcome to join! Airmodus Ltd. Erik Palménin aukio 1 00560 Helsinki, Finland FI23103192 +358 50 5666043 www.airmodus.com info@airmodus.com sales@airmo

Open the catalog to page 1
A10 PSM - 2

Measurement range Aerosol sample flow 2.5 lpm Sample flow to CPC 1 – 1.5 lpm. Other flows possible. Please contact for details. Working fluid Sample conditions Pressure: 90 to 105 kPa Relative humidity: 0 to 95% non-condensing** Environmental conditions Temperature: 15oC to 30oC Pressure: 90 to 105 kPa Relative humidity: 0 to 95% non-condensing Serial: RS-232 USB: type B connector Analog out: BNC connector 0 to 10 V for external devices, e.g. controlling of a DMA or ion filter. All communication based on ASCII character-encoding scheme. External vacuum: fitting for 1/4 in. tubing External...

Open the catalog to page 2

All Airmodus Oy catalogs and technical brochures

  1. A23 bCPC

    2 Pages

  2. A20 bCPC

    2 Pages