1. Catalogs
  2. Airmar Technology
  3. EchoRange™ Smart™ Sensors

EchoRange™ Smart™ Sensors
1 /4Pages

EchoRange™ Smart™ Sensors

EchoRange™ Smart™ Sensors
1 /4Pages

Catalog excerpts

EchoRange™ Smart™ Sensors-1

EchoRange™ Smart™ Sensors Available in Single and Dual Frequency Models Best Valued Portable Depth Sensors for Hydrographic Surveying 200 kHz and 30/200 kHz Transducers with Embedded Signal Processing Accurate measurement of water depth from 0.4 m to 200 m • Hydrographic surveying of harbors, waterways and coastal water areas • Dredging management operations • Mobile field work What makes Airmar sensors smarter than the rest? Airmar’s patented Smart™ sensors feature embedded microelectronics that process depth and temperature inside the sensor that can be instantly displayed on any device that accepts NMEA data. EchoRange™ transfers NMEA 0183 data in real time to a computer via RS422. Customizable Operation The EchoRange™ can be successfully operated in most open water applications using the factory default settings. In other applications (such as when deployed in enclosures, or when using multiple devices, or when using with battery power) the user can optimize the EchoRange™ performance by changing one or some combination of the factory default settings. When performance matters most we’ve got you covered.

 Open the catalog to page 1
EchoRange™ Smart™ Sensors-2

EchoRange™ Smart™ Sensors SS510 Single Frequency *Echo envelope developer option is also available to OEM’s SS510 HOUSING DIMENSIONS * SS510 weight 5.5 lbs. with 20 m of cable * M195 weight 13 lbs. with 20 m of cable OPERATIONAL CURRENT DRAW OPERATIONAL CURRENT DRAW 9 V peak (during ping) input current: 1 A 9 V peak (during ping) input current: 2 A 9 V average input current: 150 mA 9 V average input current: 400 mA 12 V peak (during ping) input current: 1 A 12 V peak (during ping) input current: 1.7 A 12 V average input current: 150 mA 12 V average input current: 300 mA 24 V peak (during ping)...

 Open the catalog to page 2
EchoRange™ Smart™ Sensors-3

ACCURACY (Based on tank testing) Actual Reported Difference % Note: A minumum test tank of 50 galllons is recommended as smaller tanks may induce reverberation and interfere with measurements. Mounting options: • Portable Mount: Installation on poles for hydrographic survey • Transom Mount: Optional mounting bracket available, Airmar P/N#33-652-01 • Hull Mount: Custom, based on mounting location Exclusive to OEM's Only — Echo Envelope Developer Option In addition to the bi-directional NMEA 0183 interface, a secondary transmit only interface with a proprietary protocol using RS485 is available...

 Open the catalog to page 3
EchoRange™ Smart™ Sensors-4

Contact [email protected] for more information. To request EchoRange™ Application Notes (3 pages), email with 'EchoRange™ App Notes' in the subject line. www.airmar.com ©2023 Airmar Technology Corporation EchoRange_rN 02/21/24 As Airmar constantly improves its products, all specifications are subject to change without notice. All Airmar products are designed to provide high levels of accuracy and reliability, however they should only be used as aids to navigation and not as a replacement for traditional navigation aids and techniques. EchoRange™ and Smart™ Sensors is a trademark of Airmar...

 Open the catalog to page 4

All Airmar Technology catalogs and technical brochures

  1. AR50

    1  Page

  2. ATK200

    1  Page

  3. ATK120

    1  Page

  4. ATK75

    1  Page

  5. ATK50

    1  Page

  6. AT300

    1  Page

  7. AT225

    1  Page

  8. AT200

    1  Page

  9. AT120

    1  Page

  10. AT75

    1  Page

  11. AT50

    1  Page

  12. ART15

    1  Page

  13. ARK120-THD

    1  Page

  14. ARK75-THD

    1  Page

  15. ARK50-THD

    1  Page

  16. ARK50

    1  Page

  17. ARK41

    1  Page

  18. ARK30

    1  Page

  19. AR50CH

    1  Page

  20. T1

    1  Page

  21. AR30

    1  Page

  22. DX900+

    2  Pages

  23. CAST App

    2  Pages

  24. HT200

    2  Pages

  25. G2183

    2  Pages

  26. GH2183

    2  Pages

  27. AR41

    1  Page

  28. 110WX, 200WX

    4  Pages

  29. 220WXH

    4  Pages

  30. WXS Series

    2  Pages

  31. 200WX-IPX7

    2  Pages

  32. CM510L

    2  Pages

  33. B122

    2  Pages

  34. ST900 ST950

    2  Pages

  35. TDT1000

    2  Pages

  36. SS82 SS134

    2  Pages

  37. B17-HP

    2  Pages

  38. DT800

    2  Pages

  39. DST800

    2  Pages

  40. P39

    2  Pages

  41. T80 T42

    2  Pages

  42. ST69

    2  Pages

  43. ST63

    2  Pages

  44. ST61

    2  Pages

  45. ST300

    2  Pages

  46. M563

    2  Pages

  47. TM260

    2  Pages

  48. TM258

    2  Pages

  49. SS264N Pair

    2  Pages

  50. M260

    2  Pages

  51. B260 SS260

    2  Pages

  52. B258

    2  Pages

  53. B164 SS164

    2  Pages

  54. P79

    2  Pages

  55. P74

    2  Pages

  56. B60 SS60

    2  Pages

  57. B45

    2  Pages

  58. P319 B117

    2  Pages

  59. P7

    2  Pages

  60. P19

    2  Pages

  61. P72

    2  Pages

  62. P23

    2  Pages

  63. P8 P208

    2  Pages

  64. T42

    2  Pages

  65. P66

    2  Pages

  66. P58

    2  Pages

  67. B744V B744VL

    2  Pages

  68. M190

    2  Pages

  69. SS549

    2  Pages

  70. M42

    2  Pages

  71. CS229

    2  Pages

  72. M192

    2  Pages

  73. M159

    2  Pages

  74. M153

    2  Pages

  75. M194

    1  Page

  76. M157

    2  Pages

  77. H2183

    2  Pages

  78. SS538

    2  Pages

  79. SS510

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.