ARK50
1Pages

{{requestButtons}}

Catalog excerpts

ARK50 - 1

Ultrasonic Air Transducer Technical Data Sheet Airmar ultrasonic transducers deliver the highest level of performance in the most challenging environments and they are the key component for our customers success and their applications. Our precision tuned air-ranging transducers are tried and true performers, even when used for difficult tasks. American-made from the highest quality materials, Airmar’s ultrasonic transducers provide reliable, long-lasting excellence to any measurement system. 50 kHz AIRDUCER® Ultrasonic Transducer Applications • Level measurement in chemically aggressive environments • Food and beverage processing • Flow monitoring • Proximity sensing Best Operating Frequency: 50 kHz, ±4% Minimum Transmit Sensitivity at Best Transmit Frequency: 105 dB re 1µPa/V at 1 m Minimum Receive Sensitivity at Best Receive Freq.: -170 dB re 1V/µPa Minimum Parallel Resistance: 350 Ω, ±30% Minimum and Maximum Sensing Range*: 30 cm to 15 m Typical Sensing Range: 35 cm to 10 m Free (1 kHz) Capacitance: 5,000 pF, ±20% pF Beamwidth (@ -3 dB Full Angle): 10°, ±2° Maximum Driving Voltage (2% Duty Cycle Tone Burst): 1,000 Vpp Operating Temperature: -40°C to 90°C Weight: 250 g Housing Material: Kynar® 720 Acoustic Window: Kynar® 720 Features • Rugged one-piece PVDF housing is U.S. FDA compliant • ousing design will accommodate transceiver and ignal H s processing electronics • Standard internal shielding Options • able length can be customized C • 10 KΩ thermistor available for temperature ompensation c • Mounting cap available in BSP, NPT or M32 threads • Available in alternate housing (AR50) *Pulse-Echo Mode: Minimum and maximum ranges are best case scenarios. Actual range may vary, depending on drive circuitry and signal processing. Note: Optimally, performance measurements should be taken when the t ransducer reaches a steady state. Transmit & Receive Voltage Response Impedance Magnitude & Phase Directivity Pattern Thread Choices: 1" tapered BSP x 0.75" long 1" NPT x 0.94" long (ref.) M32-1.5 x 0.75" long May be shown with optional equipment. Additional Resources Theory of Operations Applying Ultrasonic Technology Airmar’s T1 Developer’s Transceiver Module can be used for evaluation of AIRDUCER® Transducers. ©Airmar Technology Corporation ARK50_rE 04/11/24 As Airmar constantly improves its products, all specifications are subject to change without notice. All specifications typical at 22°C. Factory Mutual approved models suitable for: Class I, Division 1, Hazardous Locations. AIRDUCER® is a registered trademark of Airmar Technology Corporation. AMPHENOL is a registered trademark of Amphenol Corporation. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affili

Open the catalog to page 1

All Airmar Technology catalogs and technical brochures

  1. DX900+

    2 Pages

  2. CAST App

    2 Pages

  3. HT200

    2 Pages

  4. G2183

    2 Pages

  5. GH2183

    2 Pages

  6. T1

    1 Pages

  7. ART15

    1 Pages

  8. ATK75

    1 Pages

  9. ATK50

    1 Pages

  10. ATK200

    1 Pages

  11. ATK120

    1 Pages

  12. AT75

    1 Pages

  13. AT50

    1 Pages

  14. AT300

    1 Pages

  15. AT225

    1 Pages

  16. AT200

    1 Pages

  17. AT120

    1 Pages

  18. ARK75-THD

    1 Pages

  19. ARK50-THD

    1 Pages

  20. ARK41

    1 Pages

  21. ARK30

    1 Pages

  22. AR50CH

    1 Pages

  23. AR50

    1 Pages

  24. AR41

    1 Pages

  25. AR30

    1 Pages

  26. ARK120-THD

    1 Pages

  27. 110WX, 200WX

    4 Pages

  28. 220WXH

    4 Pages

  29. WXS Series

    2 Pages

  30. 200WX-IPX7

    2 Pages

  31. CM510L

    2 Pages

  32. B122

    2 Pages

  33. ST900 ST950

    2 Pages

  34. TDT1000

    2 Pages

  35. SS82 SS134

    2 Pages

  36. B17-HP

    2 Pages

  37. DT800

    2 Pages

  38. DST800

    2 Pages

  39. P39

    2 Pages

  40. T80 T42

    2 Pages

  41. ST69

    2 Pages

  42. ST63

    2 Pages

  43. ST61

    2 Pages

  44. ST300

    2 Pages

  45. M563

    2 Pages

  46. TM260

    2 Pages

  47. TM258

    2 Pages

  48. SS264N Pair

    2 Pages

  49. M260

    2 Pages

  50. B260 SS260

    2 Pages

  51. B258

    2 Pages

  52. B164 SS164

    2 Pages

  53. P79

    2 Pages

  54. P74

    2 Pages

  55. B60 SS60

    2 Pages

  56. B45

    2 Pages

  57. P319 B117

    2 Pages

  58. P7

    2 Pages

  59. P19

    2 Pages

  60. P72

    2 Pages

  61. P23

    2 Pages

  62. P8 P208

    2 Pages

  63. T42

    2 Pages

  64. P66

    2 Pages

  65. P58

    2 Pages

  66. B744V B744VL

    2 Pages

  67. M190

    2 Pages

  68. SS549

    2 Pages

  69. M42

    2 Pages

  70. CS229

    2 Pages

  71. M192

    2 Pages

  72. M159

    2 Pages

  73. M153

    2 Pages

  74. M194

    1 Pages

  75. M157

    2 Pages

  76. H2183

    2 Pages

  77. SS538

    2 Pages

  78. SS510

    2 Pages