Engine GENERATORSDG series
8Pages

{{requestButtons}}

Catalog excerpts

Engine GENERATORSDG series - 1

OUR PLANTS ARE CERTIFIED RECOGNIZED AS BEING WORTHY OF ISO 9001/14001 CERTIFICATION. Engine GENERATOR SDG series Niigata plant: Shimo Aozu,Tsubame-shi,Niigata-ken,Japan. Engine GENERATOR SDG series Operate safely in accordance with proper operation manual. To prevent trouble and accidents, perform daily and preventive maintenance checks without fail. 8th Floor Shinjuku San-Ei Bldg., 22-2 Nishi-Shinjuku 1-Chome, Shinjuku-ku, Tokyo 160-0023 Japan Tel : Tokyo 03(3348)7281 Fax : Tokyo 03(3348)7289 e-mail : info@airman.co.jp URL : http://www.airman.co.jp HOKUETSU INDUSTRIES EUROPE B.V. Aalsmeerderdijk 156, 1438 AX Oude Meer, The Netherlands Tel : +31-(0)20-6462636 Fax : +31-(0)20-6462191 e-mail : info@hokuetsu.nl Environmental Containment Onsite Type SDG150S-F

Open the catalog to page 1
Engine GENERATORSDG series - 2

“AIRMAN” MOST ADVANCED GENERATOR Applicable for every field and jobsite!! Further environment friendly!! 10.5 220kVA Environmental Containment Onsite Type SDG-F series t Poin Continuous operation for the time from 1 day & half 3 days A big capacity fuel tank equipped as a standard one enables long continuous operation without any additional fuel tank provided. Continuous operation Unlike separate fuel bund and generator oil bund, Airman’s fully bunded with extended tank minimize any potential of rain water penetration into the bund and minimize the maintenance work required. ●Prevention of...

Open the catalog to page 2
Engine GENERATORSDG series - 3

High Generating Performance Fully Equipped Better Generating Performance SDG series generators are coupled to low transient reactance alternator and reinforced damper coil. This increases the negative-phase-sequence current capability and minimizes the output waveform distortion. Therefore, they are suitable for wide range of non-linear load such as inverter, thyrister, computer control, discharge lighting, precision instruments and instrumental device. Dual Voltage Models Preset Voltage Regulation By changing over the short connecting plate in the control panel, the three phase output...

Open the catalog to page 3
Engine GENERATORSDG series - 4

Easy Maintenance Fuel air-bleeding electromagnetic pump Fuel filter Fuel pump Engine Starting Efficiency Reserve tank Electronic Governor For SDG13~220, engine preheating system consists of quick heating glow plug to easily start up engine in low temperature conditions. SDG220~500 are driven by high start-up engine which exercises great power for earth auger and vibro-hammer operations requiring instant electric flow. Start-up characteristics have been more improved for electric motor start-up as well as turbo charger and governor improved. Stable engine speed can be secured because engine...

Open the catalog to page 4
Engine GENERATORSDG series - 5

SPECIFICATIONS Model Generator Frequency Rated Output Voltage Power Factor Exciting Method No. of Phase Rated Output Direct Injection,Turbo charged Swirl Chamber Direct Injection, Turbo charged,Intercooled Rated Output Speed Direct Injection,Turbo charged 15.24 Direct Injection,Turbo charged,Intercooled 11.94 Direct Injection,Turbo charged,Intercooled 15.24 Fuel Consumption(50/75%Load) L/hr Lublicating Oil Capacity Dimensions & Weight Dimensions & Weight Overall Length Overall Width Overall Height Operating Mass Sound Level Sound Level For other voltages than above-mentioned ones, contact...

Open the catalog to page 5
Engine GENERATORSDG series - 6

Environmental Containment Onsite Type ULTRA SUPER SILENT Environmental Containment Onsite Type SDG-F Series SDG-AS-F Series SPECIFICATIONS Model Generator Frequency Rated Output Voltage Power Factor Exciting Method No. of Phase Frequency Rated Output Voltage Power Factor Make and Model No. of Cylinder Type(4Cycle,Water-Cooled) Fuel Tank Capacity Cooling Water Capacity Fuel Tank Capacity Dimensions & Weight Overall Width Overall Height Net Dry Mass Operating Mass Sound pressure level Rated Output Speed Direct Injection,Turbo charged Dimensions & Weight Sound Level Sound power level in...

Open the catalog to page 6
Engine GENERATORSDG series - 7

ULTRA SUPER SILENT SDG-AS Series List of Optional Equipment SDG13 Model / Item Standard equipment Option upon manufacture Automatic Starting System With built-in battery charger Manual Operated Parallel Operation System Auto-Parallel Operation System Fuel Auto-feed System Three way valve Fuel Feed from outside tank Engine Oil Auto-Feed System Flange at outlet of muffler Protection against salt damage Anti-theft cover Engine Oil Temperature Meter Automatic starting system and battery charger cannot be built into at the same time. SPECIFICATIONS Model General purpose Emergency backup...

Open the catalog to page 7
Engine GENERATORSDG series - 8

Selection of Optimum Generators Example of AC arc welder AC arc welder is in general single phase load. So when a three phase generator is used for single phase load, it shall be equally connected to three phase. Three times more generating power is required for single load welding. Generators are capable of operating following numbers of arc welders. Model Frequency(Hz) 180A 200A 250A 300A 400A 500A Engine generators are used for large and small various type electric motors. In general capacity of electric motor is specified in kW or PS. This shows motor output capacity, not motor input...

Open the catalog to page 8

All AIRMAN HOKUETSU Industries CO. catalogs and technical brochures