AMEOF120-HAMJZ - 1

Your Power Partner AC-DC Converter The AMEOF120-HAMJZ series is one of Aimtec's compact size 120W AC/DC converter with active PFC, which is also suitable for medical equipment. It features a universal AC input and accepts a DC input voltage, while also coming standard with high efficiency, high reliability and double or reinforced isolation. These converters offer excellent EMC and safety performance and meet IEC/EN/UL62368, GB4943, IEC/EN60335, IEC/EN61558, IEC/EN/ES60601 standards. This series is suitable for industrial, streetlight control, security, telecommunications, smart home and medical applications. Universal Input: 85 - 264VAC/120 - 370VDC Active power factor correction Low leakage current: 0.1mA max. High isolation voltage: 4000VAC Output short circuit, over-current, over-voltage over-temperature protection Low no-load power consumption of 0.3W Suitable for Type BF application Designed to meet IEC/EN/UL62368, EN60335, EN61558, IEC/EN/ES60601-1 Input voltage Output voltage Isolation Power Temp. range Derating Coming Soon! Product Training Video Application Notes

Open the catalog to page 1
AMEOF120-HAMJZ - 2

■ aimbec Your Power Partner Single Output Input Output Maximum Add suffix -F for enclosed package. (ex. AMEOF120-12SHAMJZ-F is enclosed package version) * Maximum duration 10S when working at the max output wattage. Minimum cool down time 30 minutes after reaching the max output wattage. Output wattage cannot exceed the nominal output wattage when the output voltage is trimmed up.l Inrush current Leakage Power factor 115VAC, cold start 230VAC, cold start 240VAC, normal condition 240VAC, single fault condition 115VAC, 100% load 230VAC, 100% load Output Specifications Parameters * Ripple and...

Open the catalog to page 2
AMEOF120-HAMJZ - 3

■ aimbec Your Power Partner

Open the catalog to page 3
AMEOF120-HAMJZ - 4

Safety Specifications Parameters Design to meet IEC/EN/UL62368-1, EN60335, IEC/EN61558, IEC/EN60601, ES60601-1 V3.1, CAN/CSA-C22.2 No.60601-1:14 Ed3, EN60601-1-2 Ed4, GB4943-1 CISPR32 / EN55032, conducted class B EMC - Conducted and radiated emission* CISPR32 / EN55032, radiated class B with protective earth connection CISPR32 / EN55032, radiated class A without protective earth connection EMC - Harmonic current emissions* IEC 61000-3-2 class A Standards Electrostatic Discharge Immunity IEC 61000-4-2 Contact ±8KV, Air ±15KV, Criteria A RF, Electromagnetic Field Immunity IEC 61000-4-3 10V/m,...

Open the catalog to page 4
AMEOF120-HAMJZ - 5

Your Power Partner Dimensions Open frame model Pin Output Specifications 1. It is needed to have > 10mm distance between the product and external components for safety. 2. Connect mounting point 1 and 4 to protective earth for Class I system. 3. Connect mounting point 1 and 4 together for Class II system.

Open the catalog to page 5
AMEOF120-HAMJZ - 6

Enclosed model Recommend fan 40 x 40 x 15mm 10CFM 50.8 (2.00) The customer system case Power Supply Case L Note: Unit: mm [inch] General tolerance: ±1.00 (±0.04) Mounting screw: M3 Mounting screw tightening torque: 0.4N max. Case must be connected to PE NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based...

Open the catalog to page 6