Vibration-english-1

11/2025 • We reserve the right to make technical changes. Technical data and functions • Measurement of vibrations on bearings or housings for machine monitoring. • The vibration is measured in the axial direction of the sensor in a defined frequency band. • Different types for three measured variables: - Vibration acceleration (without integrator), particularly suitable for higher-frequency vibrations, e.g. on roller bearings or gears and for shocks. - Vibration velocity (integrator), particularly suitable for machine condition monitoring according to ISO 20816. - Vibration displacement (double integrator), particularly suitable for measuring the vibration amplitude on vibrating conveyors, vibrating screens and sifters. • Suitable for use in harsh environmental conditions. • Record vibrations as close as possible to their source. Flat coupling surfaces with low roughness are suitable. Rough cast surfaces or painted surfaces are unsuitable. • Sensors comply with the specifications for vibration severity measuring devices according to ISO 2954, among others. • Possible fields of application are: - Measurement of running smoothness on rotating machines and reciprocating machines in accordance with ISO 10816 / ISO 20816 - Measurement of bearing vibrations according to VDI 3832 - Measurement of vibrations in defined frequency bands Measuring -axis Explanation of terms • RMS: Root mean square value • Peak-to-peak: Full vertical length of the sine curve • Integrator: Electrical circuit that integrates an input signal over time • Vibration amplitude: Maximum distance that a vibrating object reaches from its center position • Frequency band: Defined range of frequencies between the lower and upper limit frequencies • Break acceleration: Load limit of the sensor, specified in g (acceleration due to gravity) • Coupling surface: Surface to which the sensor is attached • Roughness: Unevenness of the surface height • Smooth running: Trouble-free running of a machine • DIN ISO 2954: Standard „Mechanical vibration of reciprocating machines and of machines with rotating components - Requirements for vibration severity meters“ • ISO 10816 and ISO 20816: IEC standards for mechanical vibrations • VDI 3832: VDI guideline for structure-borne noise measurements for assessing the condition of rolling bearings in machines and systems

 Open the catalog to page 1
Vibration-english-2

Technical Data: Piezo system Shear principle Measured variable, see Variants nominal measuring range Accuracy 2 % of final value (for measured values > 1 % of measuring range end value) Lower limit frequency see Variants Upper limit frequency see Variants Operating temperature range -40 ... +100 °C Temperature coefficient +0.015 %/K operating temperature range 4 mA offset drift over time ±1 gA Mass without cable 60 g Housing material stainless steel Connection direction axial Mounting Threaded hole M8 x 5.5 Connection socket M12, four-pin, male (Binder 713) Supply voltage 15 V via ALMEMO® plug...

 Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Certificates

    8  Pages

  2. Conductivity

    2  Pages

  3. pH-english

    4  Pages

  4. Trigger cable

    3  Pages

  5. RTA5-english

    1  Page

  6. RTA6-english

    1  Page

  7. Cases

    1  Page

  8. ODBC-english

    4  Pages

  9. Web server

    4  Pages

  10. PIMEX-english

    4  Pages

  11. Thermo-wires

    3  Pages

  12. FIA20-english

    2  Pages

  13. MI30-english

    2  Pages

  14. MI40-english

    2  Pages

  15. Pitot Tubes

    2  Pages

  16. Force-english

    3  Pages

  17. Displacement

    2  Pages

  18. Speed

    1  Page

  19. Flow

    2  Pages

  20. Wind sensor

    2  Pages

  21. Comfort Index

    2  Pages

  22. Sound Level

    1  Page

  23. Moisture

    5  Pages

  24. CO sensor

    1  Page

  25. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.