Various gases

Various gases

Product catalog summary
Technical Specifications:
The ADOS 592 TOX gas probe is designed for measuring various gas concentrations in the air using an electrochemical reaction principle. The measurement range varies according to the model variant. The error margin for measurement values is ±3% of the full scale value, with a zero point drift of less than 2% over one year. Reproducibility and linearity are both under 2% of the full scale value. The settling time (t90) is less than 60 seconds, and transverse sensitivity is minimized to under 2% by an integrated filter.

Operating Conditions:
Nominal conditions for operation are 20°C, 50% relative humidity, and 1013 mbar. The device operates effectively between -10 to +40°C, with temperature compensation for the sensor, and in humidity levels from 15% to 90% non-condensing. The measurement cell has an approximate lifespan of two years.

Output and Power Supply:
The output is 4 to 20 mA via an ALMEMO® connector, with a supply voltage of 24 V. The measurement head dimensions are 80 mm in diameter and height, weighing 600 g. It includes a 1.5 m connecting cable with an ALMEMO® connector.

Model Variants and Ranges:
The device is available in multiple model variants, each tailored for specific gases:
  • Ammonia (NH3): 0 to 250 ppm
  • Nitrogen dioxide (NO2): 0 to 30 ppm
  • Nitrogen oxide (NO): 0 to 50 ppm
  • Chlorine gas (Cl2): 0 to 50 ppm
  • Sulfur dioxide (SO2): 0 to 250 ppm across three variants
  • Hydrogen sulfide (H2S): 0 to 250 ppm across two variants
  • Ethylene oxide (C2H4O): 0 to 100 ppm across three variants

Important Note:
The device cannot operate in SLEEP mode. Each model variant comes with a factory test certificate.

Additional Information:
The document notes that technical changes may be made, with the last update being November 2026.
See more

Catalog excerpts

Various gases-1

Measurement of gas concentration in air Multiple ranges / Model variants Operation with the device in SLEEP mode is not possible! Technical Data Gas: see model variants Measuring principle: electrochemical reaction Measuring range: see model variants Error of meas. value: ±3 % of full scale value Zero point drift: < 2 % (1 year) Linearity: < 2 % of full scale value Transverse sensitivity: < 2 % by integrated filter Nominal conditions: 20 °C, 50 % r.H., 1013 mbar Operating conditions: -10 to +40 °C, Sensor in range temperature compensated > 15 to 90 % r.H. non-condensing Life span of the meas. cell: approx. 2 years typical Output: 4 ... 20 mA on ALMEMO® connector Supply voltage: 24 V via ALMEMO® connector Dimensions of meas. head: 0 80 mm, height 80 mm Weight: 600 g Connecting cable: 1.5 m, with ALMEMO® connector 11/2026 • We reserve the right to make technical changes. Model variants (including factory test certificate) Gas probe, including connecting cable, 1.5 meters, for measuring gas in air Ammonia NH3 Range: 0 ... 250 ppm Nitrogen dioxide NO2 Range: 0 ... 30 ppm Nitrogen oxide NO Range: 0 ... 50 ppm Chlorine gas Cl2 Range: 0 ... 50 ppm Sulfur dioxide SO2 Range: 0 ... 20 ppm Range: 0 ... 50 ppm Range: 0 ... 250 ppm Range: 0 ... 20 ppm Range: 0 ... 50 ppm Range: 0 ... 100 ppm

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.