Trigger cable

Trigger cable

Trigger cable

Product catalog summary
ALMEMO® Trigger Cable V6 ZA 1006 ET / ZA 1006 EK2
  • Trigger Input: ZA1006ET can be programmed with a key; ZA1006EK2 supports external zero-potential contact and voltage (4 to 30 VDC).
  • Current Consumption: Approximately 3 mA.
  • Cable Length: 1.5 meters.
ALMEMO® Trigger / Relay Cable V6 ZA 1006 EKG / ETG
  • Trigger Input: Supports external zero-potential contact or voltage (4 to 30 VDC).
  • Relay: Normally open contact, programmable as inverted, with a load capacity of 50 VDC, 0.5 A, 1 ohm.
  • Current Consumption: Approximately 3 mA.
  • Cable Length: 1.5 meters.
Relay Cable V6 ZA 1006 GK
  • Relay: Normally open, programmable as inverted, with a load capacity of 50 VDC, 0.5 A, 1 ohm.
  • Current Consumption: Approximately 3 mA.
  • Cable Length: 1.5 meters.
ALMEMO® Analog Output Cable ZA 1601 RK
  • Converts device signal into voltage corresponding to the linearized measured value.
  • Conversion rate of 10 mops can be set for high response speed.
  • Output signal can be scaled as required.
Relay Adapter ZB2280RA
  • Control Input: For optocoupler output or switching contact R <10 kW.
  • Output: Electrical safety socket, mechanical relay, load capacity 230 V, 6 A.
ALMEMO® Analog Output Cable ZA 1601-RI and ZA 1602-RU
  • Output Signal: ZA1601RI provides 0 to 20 mA, ZA1602RU provides 0 to 10 V.
  • Resolution: ZA1601RI at 1 µA/digit, ZA1602RU at 0.5 mV/digit.
  • Accuracy: 0.1% of measured value + 0.1% of final value.
  • Power Supply: 12 V via ALMEMO® plug.
Compatibility: Suitable for ALMEMO® devices manufactured from 2020 onwards; older devices require a firmware update.
See more

Catalog excerpts

Trigger cable-1

Technical Data Trigger input ZA1006ET Trigger variants can be programmed ZA1006EK2 For external zero-potential contact (not electrically isolated) and for external voltage 4 to 30 VDC (optocoupler), trigger variants can be programmed Current consumption approx. 3 mA Cable length 1.5 meters ALMEMO® trigger cable, V6, with 1 key ZA1006ET ALMEMO® trigger cable, V6, with 2 trigger inputs for external contacts or voltages, with clamp connector ZA1006EK2 Trigger input For external zero-potential contact (not electrically isolated) or for external voltage 4 to 30 VDC (optocoupler) Trigger variants - can be programmed (V6 only) Relay Normally open contact (semiconductor relay) Can also be programmed as inverted (V6 only) Load capacity: 11/2025 • We reserve the right to make technical changes. Current consumption approx. 3 mA Cable length 1.5 meters Connection Clamp connector Variants ALMEMO® trigger / relay cable, V6, with 2 trigger inputs (programmable trigger variant) for external voltages and 2 normally open contacts ALMEMO® trigger / relay cable, V6, with 2 trigger inputs (programmable trigger variant) for external zero-potential contacts and 2 normally open contacts

 Open the catalog to page 1
Trigger cable-2

Relay cable, V6, type ZA 1006 GK_ Relay Normally open (semiconductor relay) Can also be programmed as inverted (V6 only) Load capacity 50 VDC, 0.5 A, 1 ohm Current consumption approx. 3 mA Cable length 1.5 meters Connection Banana plug Control input for optocoupler output or switching contact R <10 kW Output Electrical safety socket, mechanical relay, load capacity 230 V, 6 A Switching status OFF idle; ON alarm 01/2026 • We reserve the right to make technical changes. ALMEMO® relay cable, V6, with 1 normally open contact Order no. Variants Order no. Relay adapter for switching mains supplied...

 Open the catalog to page 2
Trigger cable-3

• The analog signal is controlled internally by the measured value of a measuring channel, arbitrarily scalable. • Respectively, the analog signal is controlled externally via the device interface with the WinControl software. ! Only suitable for the following device types: 104, 710, 809 devices manufactured from 2020 onwards (for older devices, a firmware update is necessary). Output signal: via clamping connector, galvanically isolated (common mass) Accuracy: 0.1 % of measured value Temperature drift: 10 ppm/K Power supply: 12 V via ALMEMO® plug the sensor voltage 12 V is set on the ALMEMO®...

 Open the catalog to page 3

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. RTA5-english

    1  Page

  2. RTA6-english

    1  Page

  3. Cases

    1  Page

  4. ODBC-english

    4  Pages

  5. Web server

    4  Pages

  6. PIMEX-english

    4  Pages

  7. Thermo-wires

    3  Pages

  8. FIA20-english

    2  Pages

  9. MI30-english

    2  Pages

  10. MI40-english

    2  Pages

  11. Pitot Tubes

    2  Pages

  12. Force-english

    3  Pages

  13. Displacement

    2  Pages

  14. Speed

    1  Page

  15. Flow

    2  Pages

  16. Wind sensor

    2  Pages

  17. Comfort Index

    2  Pages

  18. Sound Level

    1  Page

  19. Moisture

    5  Pages

  20. pH-english

    4  Pages

  21. Conductivity

    2  Pages

  22. CO sensor

    1  Page

  23. Certificates

    8  Pages

  24. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.