Temperature NiCr-Ni sensor with handle FTA 120x Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -200...+400 °C Silver rivet, level, spring-loaded, not electrically isolated 3s T90*: Handle*: 138 mm Cable: 1.5 m PVC For surface measurement and immersion measurement NiCr-Ni sensor with handle FTA 122 LxxxxH Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -200...+400 °C Silver rivet, level, not electr. isolated 3s T90*: Handle*: 127 mm Cable: 1.5 m FEP/silicone thermal line** For surface measurement and immersion measurement Order no. FTA122L0050H Order no. FTA122L0100H Order no. FTA122L0200H NiCr-Ni sensor with handle FTA 121 LxxxxH Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -200...+400 °C Silver rivet, level, angled, not electrically isolated 3s T90*: Handle*: 127 mm Cable: 1.5 m FEP/silicone thermal line** For surface measurement and immersion measurement 11/2025 • We reserve the right to make technical changes. NiCr-Ni sensor with handle FTA 150 LxxxxH Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -200...+800 °C Stainless-steel rivet, level, electrically isolated 3s T90*: Handle*: 127 mm Cable: 1.5 m FEP/silicone thermal line** For surface measurement and immersion measurement Order no. FTA150L0350H Order no. FTA150L0700H Order no. FTA150L1250H * Range of validity see beginning of chapter ** There is no adverse temperature effect at the juncture from measuring element to cable. See beginning of chapter DAkkS accredited calibration or factory calibration KT90xx temperature for sensor or measuring chain (sensor + device), see chapter „Calibration certificates“. DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 1702
Open the catalog to page 1Accuracy: NiCr-Ni class 2* Measuring tip: Operative range -50...+500 °C Thermal ribbon, not electr. isolated Measuring head approx. 15 mm diameter T *: 1 s Cable: 1.5 m FEP/silicone thermal line** L = approx. 180 mm Order no. FTA109P Sensor with handle Order no. FTA109PH (No variants available) NiCr-Ni sensor FTA 104 P 11/2025 • We reserve the right to make technical changes. Accuracy: NiCr-Ni class 2* Measuring tip: Operative range -50...+500 °C Thermal ribbon, not electr. isolated Measuring head approx. 15 mm diameter T *: 1 s Cable: 1.5 m FEP/silicone thermal line** with 90 ° angle, approx....
Open the catalog to page 2Temperature NiCr-Ni sensor with handle FTA 420 LxxxxH Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -50...+500 °C Silver disc, spring-loaded, not electrically isolated 2s T90*: Handle*: 127 mm Cable: 1.5 m FEP/silicone thermal line** For surface measurement on level surfaces NiCr-Ni sensor FTA 025 P Accuracy: NiCr-Ni class 2* Measuring tip: Operative range -50...+250 °C Thermal ribbon, not electr. isolated Fastened by magnet 1.5 s T90*: Cable: 2 m silicone thermal line** Magnet sensor (No variants available) Order no. FTA025P Magnet sensor for surface measurement Velcro fastener:...
Open the catalog to page 3Temperature Accuracy: NiCr-Ni class 2* Measuring tip: Operative range -50...+100 °C Silver rivet, level, spring-loaded, not electrically isolated Fastened by magnet 3s T90*: Cable: 3 m FEP/silicone Magnet sensor for surface measurement Magnet sensor NiCr-Ni sensor FTA 026 P Accuracy: NiCr-Ni class 1* Measuring tip: Operative range -50...+250 °C Thermal ribbon, not electrically isolated 1.5 s T90*: Cable: 0.9 m line, PTFE compensating cable For surface measurement Ribbon sensor Order no. FTA026P (No variants available) NiCr-Ni sensor FTA 8068 Accuracy: NiCr-Ni class 2* Measuring tip: Operative...
Open the catalog to page 4NiCr-Ni film thermocouple FTA 683 For surface measurement Accuracy: NiCr-Ni class 2* Measuring tip: Operative range -100 to +200 °C Foil, Insulation Kresol T *: 2 s with permanently connected FEP / silicone thermal line (stranded wire)** -50 to +200 °C, 2 meters, with ALMEMO® connector Measuring element without cable, free ends (for your own sensors) Order no. FT0683 08/2026 • We reserve the right to make technical changes. Accuracy: NiCr-Ni class 2* Measuring tip: Thermowire, welded, not electrically isolated T *: 3 s Insulation, glass fiber, Operative range -25...+350 °C (short time up to 400...
Open the catalog to page 58 Pages
2 Pages
3 Pages
4 Pages
316 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
1 Page
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
13 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
4 Pages
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages