RTA6-english

RTA6-english

Product catalog summary
Overview: The document provides technical specifications and options for the ALMEMO® relay trigger module and trigger output interface, designed for the ALMEMO® 510 V7 data acquisition system. It includes details on functionality, configuration, and technical data.
Specifications:
  • The module supports up to 4 RTA6 plug-in units per ALMEMO® 510, with up to 10 peripheral elements each having configurable functions.
  • Relay functions include total alarm, limit value assignment, and inverse addressing for power failure alarms.
  • LEDs indicate relay states, and a watchdog function is available for device or computer addressing failures.
  • Analog outputs are programmable to 10 V or 20 mA and can be assigned to measuring channels or addressed via interface.
  • Connection is facilitated through ALMEMO® clamp connectors with protective sleeves and strain relief.
Options:
  • Basic version includes 2 trigger inputs and 4 normally open relays.
  • Additional options include extra relays and analog outputs, with possible combinations for customization.
Technical Data:
  • Trigger inputs: Optocoupler 4 to 30 V, Ri > 3 kohms.
  • Relays: Semiconductor relays 50 V, 0.5 A, 1 ohm.
  • Analog outputs: 10 V or 20 mA, 16-bit DAC, electrically isolated.
  • Accuracy: ± 0.1% of measured value and final value, with a temperature drift of 10 ppm/K.
  • Output rate: Up to 100 actions/s with 1 RTA6 plug-in module.
  • Power supply: Via ALMEMO® system, with current consumption details provided.
Conclusion: The ALMEMO® relay trigger module offers versatile and customizable options for data acquisition systems, with detailed specifications ensuring precise and reliable performance.
See more

Catalog excerpts

RTA6-english-1

ALMEMO® trigger output interface, ES 500-RTA6, for data acquisition system ALMEMO® 510 V7 Technical Data: Trigger inputs Optocoupler 4 to 30 V, Ri > 3 kohms Relays Semiconductor relays 50 V, 0.5 A, 1 ohm Analog outputs 0.0...10.0 V 0.0...20.0 mA Accuracy Temperature drift 16 bit DAC, electrically isolated 0.5 mV/Digit, Load > 100 kohms 1 pA/Digit, Load < 500 ohms ± 0.1% of meas. val. ± 0.1 % of final val. 10 ppm/K_ Output rate in total up to 100 actions/s for a system with 1 RTA6 plug-in module Power supply via ALMEMO® measuring system Current consumption Standard: approx. 10 to 20 mA 2 analog outputs: approx. 15 mA + 1.8-IOut 11/2025 • We reserve the right to make technical changes. • Universal trigger output interface for ALMEMO® 510 V7 data acquisition systems • Control from the CPU slot via internal SPI bus. • Up to 4 RTA6 plug-in units are supported per ALMEMO® 510. • Up to 10 peripheral elements (relays, trigger inputs, analog outputs) each with individually configurable function • Relay functions, total alarm, assignment to particular limit values, or addressing via interface • Inverse relay addressing for alarm in the event of power failure • Relay states shown via LEDs • Watchdog function in the event of a failure of ALMEMO® device or computer addressing • Comprehensive trigger features with the aid of command macros, addressing via electrical signals • Either 2 or 4 analog outputs (10 V or 20 mA programmable) can be assigned to any measuring channels, scalable sub-areas, or alternatively addressing via interface. • On request: 10 analog outputs per plug-in module (without trigger inputs, without relays) • Connection of peripherals via ALMEMO® clamp connectors, cable with anti-kink protective sleeve and strain relief • Power supply via ALMEMO® system. Basic version 2 trigger inputs and 4 normally open relays Options 2 additional relays (normally open) OA500SH2 Per normally open pair 2 additional normally closed relays (with normally open relays 2 changeover relays) OA500OH2 2 analog outputs (common ground), electrically isolated 10 V or 20 mA (programmable) OA500R02 Possible combinations ALMEMO® relay trigger module for data acquisition system ALMEMO® 510 V7 with 2 trigger inputs, 4 normally open relays, and 3 ALMEMO® clamp connectors ES500RTA6

 Open the catalog to page 1

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Trigger cable

    3  Pages

  2. RTA5-english

    1  Page

  3. Cases

    1  Page

  4. ODBC-english

    4  Pages

  5. Web server

    4  Pages

  6. PIMEX-english

    4  Pages

  7. Thermo-wires

    3  Pages

  8. FIA20-english

    2  Pages

  9. MI30-english

    2  Pages

  10. MI40-english

    2  Pages

  11. Pitot Tubes

    2  Pages

  12. Force-english

    3  Pages

  13. Displacement

    2  Pages

  14. Speed

    1  Page

  15. Flow

    2  Pages

  16. Wind sensor

    2  Pages

  17. Comfort Index

    2  Pages

  18. Sound Level

    1  Page

  19. Moisture

    5  Pages

  20. pH-english

    4  Pages

  21. Conductivity

    2  Pages

  22. CO sensor

    1  Page

  23. Certificates

    8  Pages

  24. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.