• Digital sensor element for humidity, temperature, air pressure All key sensor characteristics, settings, and adjustment data are saved in the sensor element itself. • Plug-in sensor element: Spare elements are inexpensive; a replacement can be fitted on site quickly and easily by virtually anyone; it will be fully accurate straight away needing no special adjustment. • Digital transfer of measured values from the sensor element to the transmitter • Four climate variables can be measured: Double analog output for temperature and one humidity variable relative humidity / dewpoint / mixture ratio. The air pressure dependent humidity values are automatically compensated for air pressure (the air pressure is measured directly at the measuring point in the • The transmitters can be configured via the internal display and the keypad. • The analog output type (10 V or 20 mA) can be selected (via the keypad); the analog output range can be programmed. • Display of measured value, channel, units, humidity range, analog start, analog end, and analog type • The sensor tube can be connected either directly by plugging onto the transmitter itself or via a connecting cable. • Suitable for conduit mounting or wall mounting 11/2025 • We reserve the right to make technical changes. Technical data Operative range Sensor -20 to +80 °C, 5 to 98 % RH Humidity sensor Sensor CMOSens® technology Fixed measuring period / output period approx. 3 seconds Accuracy ±3 % RH in range 10 to 90 % RH (incl. hysteresis) ±5 % RH in range 5 to < 98 % RH Sensor operating pressure Atmospheric pressure Response time T63 typical 8 seconds at +25 °C, 1 m/s (without filter) Temperature sensor Sensor CMOSens® technology Fixed measuring period / output period approx. 3 seconds Response time T63_typical 20 seconds (without filter)_ Double analog output Digital-to-analog converter (DAC) electr. isol. 0 to 10 V, load >100 kilohms 0 to 20 mA, load <500 ohms Output type Resolution Accuracy Temperature drift Time constant Connection Cable, via screwless clamp connector, with cable bushing Cable diameter 2 to 5 mm Standard equipment Display, internal Operation, internal Power supply DC voltage Current consumption Connection Cable, via screwless clamp connector, with cable bushing Cable diameter 2 to 5 mm Mechanical design Sensor tube Protective cap Housing Dimensions Protective class Stainless steel, diameter 12 mm SK7, metal-mesh filter Die-cast aluminum, closed cover 100 x 100 x 60 mm (LxWxH) IP65 (with sensor tube and connecting cable plugged in)
Open the catalog to page 1Display of measured values and programming (housing open) Accessories " [ Measured value display, channel M0, temperature Selecting the humidity variable, e.g. relative humidity, % RH 11/2025 • We reserve the right to make technical changes. Angle bracket for wall mounting Rubber gasket (mat) for mounting the housing directly on a conduit wall (immersion depth = 42 mm plug length) Movable brass screw with plastic sealing ring Connecting flange for screw connection, pitch circle diameter 38 mm Protective caps sensor length + approx. Connecting cable between sensor tube and transmitter Length =...
Open the catalog to page 2324 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
13 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
1 Page
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
4 Pages
2 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages