Heat Flow Plates

Heat Flow Plates

Heat Flow Plates

Product catalog summary
Technical Specifications:
Various models of heat flow plates are detailed, each with specific dimensions, substrate materials (epoxy resin or silicone), and temperature stability ranging from -40 to 80°C. Calibration values are provided for each model, indicating the heat flow density in W/m² when the plate outputs 1 mV, with an accuracy of 5% at 23°C.

Applications and Design:
The heat flow plates are designed for determining heat flow density, featuring a meander of opposing thermocouples embedded in a substrate. They are suitable for various applications, including construction, solar-electric systems, and medical uses. The plates are equipped with ALMEMO® connectors for immediate heat flow density readings.

Accessories:
Includes adhesive tapes and self-adhesive films for room temperature applications. Each plate comes with a connecting cable and a manufacturer's test certificate.

Heat Flow Sensor:
The sensor's calibration accuracy is 5% at a nominal temperature of 23°C, with temperature coefficients of -0.12%/K for epoxy plates and -0.17%/K for silicone plates. The sensor includes a miniature NTC type N element with an accuracy of ±0.5 K.

ALMEMO® D6 Plug:
Incorporates an A/D converter for measuring heat flows and temperatures. It features two measuring channels, a resolution of 0.01 K, and a refresh rate of 0.4 seconds. The plug supports a supply voltage of 6 to 13 VDC and a current consumption of 4 mA.

Digital Heat Flow Plate:
Models 117, 118, and 119 include an integrated temperature sensor for automatic correction of the temperature coefficient. These plates are available with permanently fitted cables and ALMEMO® D6 plugs.

General Features:
All models are designed for specific applications, with detailed technical data and accessories available in the ALMEMO® Measuring Instruments chapter.
See more

Catalog excerpts

Heat Flow Plates-1

For determining the heat flow density. Application-oriented designs, consisting of a meander of opposing thermocouples that are embedded in a substrate. In case of thick substrates no lateral circulation of the heat flow because of sufficient meander shell zone. Software for U value measurement, see chapter Software Each heat flow plate has been assigned a calibration value, which corresponds to the heat flow density in W/m2 when the plate provides an output of 1 mV The calibration value will be stored as factory-setting in the ALMEMO® connector so that ALMEMO® devices will immediately indicate the current heat flow density in W/m2. 11/2025 • We reserve the right to make technical changes. Technical Data: Type Dimensions Meander Size Substrate Temperature Calibr. Val. appr. Accuracy (mm)_(mm)_Stability_(W/m2 » mV)_of Calibr, Value Accessories Order no. Adhesive tape for room temperature Self-adhesive film 24 x 100 cm for room temperature Types incl. connecting cable, 2 m, with ALMEMO® connector and manufacturer's test certificate Model Application 117 for even surfaces, e.g. casement sections e.g. solar-electric systems and insulating plates 119 especially for constructional industry, brickwork insulating plates, old buildings 120 small heat flow plate, e.g. for medicine, veterinary medicine, small components etc. 117 SI flexible heat flow plate, suitable for even surfaces, 118 SI flexible heat flow plate, suitable for even surfaces, e.g. solar-electric systems and insulating plates 119 SI flexible heat flow plate, suitable for even surfaces

 Open the catalog to page 1
Heat Flow Plates-2

Heat flowDigital heat flow plate FQADx, with integrated temperature sensor for automatically correcting the heat flow plate’s temperature coefficient, with ALMEMO® D6 plug • This automatically corrects the heat flow plate’s temperature coefficient using a miniature NTC sensor integrated in the heat flow plate for the purpose of measuring the plate’s mean temperature. • It measures heat flows and temperatures using an A/D converter incorporated in the ALMEMO® D6 plug. • Two measuring channels are programmed (at our factory). • Plate’s mean temperature (°C, t) Heat flow, temperature-compensated...

 Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Trigger cable

    3  Pages

  2. RTA5-english

    1  Page

  3. RTA6-english

    1  Page

  4. Cases

    1  Page

  5. ODBC-english

    4  Pages

  6. Web server

    4  Pages

  7. PIMEX-english

    4  Pages

  8. Thermo-wires

    3  Pages

  9. FIA20-english

    2  Pages

  10. MI30-english

    2  Pages

  11. MI40-english

    2  Pages

  12. Pitot Tubes

    2  Pages

  13. Force-english

    3  Pages

  14. Displacement

    2  Pages

  15. Speed

    1  Page

  16. Flow

    2  Pages

  17. Wind sensor

    2  Pages

  18. Comfort Index

    2  Pages

  19. Sound Level

    1  Page

  20. Moisture

    5  Pages

  21. pH-english

    4  Pages

  22. Conductivity

    2  Pages

  23. CO sensor

    1  Page

  24. Certificates

    8  Pages

  25. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.