Optical radiationDigital measuring head for erythema effective UV radiation (UVE) FLD7 03-UVE with ALMEMO® D7-connectorMonitoring of UVE-radiation hazardous for human skin. Mobile measurements in meteorological, medical and biological applications. For connection to current measuring instruments ALMEMO® V7, ALMEMO® 202-S, 204, 104, 710, 510, 809 Erythema effective radiation ALMEMO® D7 digital measuring head FLD7 X3-UVE ALMEMO® UVE-measuring head 11/2025 • We reserve the right to make technical changes. Erythema effective UV radiation The natural UV radiation of the sun or the UV radiation of artificial sources has different effects to human skin dependant on the wavelength range. • The long-wave UV radiation (more than 313 nm, UVA) tans the skin and supports the human immune system. • The short-wave UV radiation (less than 313 nm, UVB/UVE) may cause irreversable damage. In the recommendation of the CIE (Commission Internationale de l‘Eclairage) all spectral effect functions which can have a negative effect on the human skin are summarized. This recommendation is described in the DIN 5050 resp. ISO/CIE 17166 and valuated as a directive. The measuring head records the erythema effective UV radiation. The spectral sensitivity of the measuring head complies with the standards DIN 5050 and ISO/CIE 17166 and the Ordinance on Protection against the Harmful Effects of Artificial Ultraviolet Radiation (UV-Schutz-Verordnung - UVSV, published in the Federal Law Gazette 2011 Part I No. 37). The measurement results provide direct information about medically and biologically relevant correlations in this radiation range. DIN 5050 specifies four different skin types: Skin type I to IV. The UV Protection Ordinance - UVSV extends by two further skin types: skin type V and VI. The guideline for these six skin types are taken into account in the calculation of the various parameters. The measuring head is used in areas of medical and biological research, for the measurement of UV radiation equipment (for cosmetic purposes, medical treatments or other human applications), in weather information and forecasting systems, in climate research and for general population information. A popular measure of „sunburn sensitivity^ is the UV index „UVI“, which is determined by the German Weather Service. The measuring head FLD7 03-UVE has a black anodized aluminum housing. The measurement is cos-corrected. The measuring head is suitable for measurements in dry environments. The measuring head works with its own AD converter. Extension cables and the ALMEMO® measuring instrument/data logger have no influence on the accuracy of the measurement. From the measured irradiance, all relevant measured variables are calculated and output to the ALMEMO® instrument. Different measuring channels can be selected and the measured variables can be displayed: • UV-index: relative irradiance related to 25 mW/m2. • Dose (erythema effective irradiation) in J/m2: sum of irradi-ance over the irradiation period (energy). • Relative minimum erythema-effective dose (MED): Dose related to 1 MED (= erythema-effective threshold irradiation) of the set skin type according to DIN 5050 and UVSV. Example: 1 MED for skin type 2 (light-skinned European skin type) = 250 J/m2. • Remaining time of irradiation in minutes until the dose 1 MED of the selected skin type is reached. • Current, predicted maximum irradiation time in minutes until the dose 1 MED of the selected skin type is reached. • Relative standard erythema effective dose (SED): Dose related to 1 SED (100 mW/m2) according to ISO 17166.

 Open the catalog to page 1
FLD703UVE-2

Optical radiationTechnical Data Measuring range UVE: 0.1 ... 300 mW/m2 Sensor system: SiC / interference filter Erythema effective spectral range: 250 ... 298 ... 328 nm Weight (without cable): approx. 50 g ALMEMO® connecting cable: fixed attached cable, 1.5 m, with ALMEMO® D7-connector Refresh rate: 1 s for all channels Settling time: 3 s (for data logger operation in sleep mode a sleep delay of 3 s has to be programmed) Power supply voltage: from 6 V from ALMEMO® instrument Power consumption: approx. 5 mA 11/2025 • We reserve the right to make technical changes. very high high Version in weatherproof...

 Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. ALMEMO® 2470

    3  Pages

  2. ALMEMO® 2890

    2  Pages

  3. ALMEMO® 104

    3  Pages

  4. ALMEMO® 710

    3  Pages

  5. ALMEMO® 500

    4  Pages

  6. ALMEMO® 510

    3  Pages

  7. ALMEMO® 809

    2  Pages

  8. ALMEMO® 5690

    8  Pages

  9. ALMEMO® 1020

    2  Pages

  10. ALMEMO® 1030

    2  Pages

  11. ALMEMO® 1033

    2  Pages

  12. ALMEMO® 1036

    2  Pages

  13. ALMEMO® 8036

    3  Pages

  14. RTA5

    1  Page

  15. RTA6

    1  Page

  16. Cases

    1  Page

  17. WinControl

    13  Pages

  18. Thermo-wires

    3  Pages

  19. FIAD43

    2  Pages

  20. FIA844

    2  Pages

  21. AMiR 7843

    2  Pages

  22. AMiR 7834

    6  Pages

  23. FHAD 36 Rx

    4  Pages

  24. FHA 646 R

    1  Page

  25. FHAD46-7

    1  Page

  26. Psychrometer

    1  Page

  27. MH8D46

    2  Pages

  28. Pitot Tubes

    2  Pages

  29. Force

    3  Pages

  30. Displacement

    2  Pages

  31. Vibration

    2  Pages

  32. Speed

    1  Page

  33. Flow

    2  Pages

  34. Wind sensor

    2  Pages

  35. FLD733UVE

    2  Pages

  36. Sound Level

    1  Page

  37. Moisture

    5  Pages

  38. Tensiometer

    1  Page

  39. FLAD03VL1

    1  Page

  40. FLA623

    3  Pages

  41. VLambda

    1  Page

  42. Luminance

    1  Page

  43. pH

    4  Pages

  44. Conductivity

    2  Pages

  45. CO sensor

    1  Page

  46. Certificates

    7  Pages

  47. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.