FLAD03VL1-english

FLAD03VL1-english

Product catalog summary
Overview: The document provides technical specifications and applications for the ALMEMO® D6 digital measuring head, specifically the FLAD 03-VL1 model, designed for measuring illuminance (V-Lambda radiation). This device is crucial for applications in workplace design, lighting projects, and various research fields.
V-Lambda Radiation: V-Lambda radiation corresponds to the visible light spectrum, ranging from 400 nm to 720 nm, with peak sensitivity at 555 nm. It measures perceived brightness in 'LUX', convertible to irradiance 'W/m²'.
Technical Specifications:
  • Measuring Range: 1 lx to 200 klx, with specific ALMEMO® ranges up to 200.00 klx.
  • Resolution: Minimum of 0.02 lx.
  • Sensor System: Si/interf. filter with spectral sensitivity from 380 nm to 720 nm.
  • Accuracy: V-Lambda adaption <3%, cos-correction error f2 < 2.0%, linearity < 1%, absolute error < 10%.
  • Temperature: Nominal 23 °C ±3 K, operating -20 °C to +60 °C.
  • Dimensions: Diameter 33 mm, height approx. 29 mm, weight approx. 50 g.
  • Connection: Permanently connected 1.5 m cable with ALMEMO® D6 connector.
ALMEMO® D6 Connector:
  • Refresh Rate: 1.5 s for all channels.
  • Stabilization Time: 3 s, with a sleep delay of 3 s for data logger operation.
  • Supply Voltage: Up to 6 V from the ALMEMO® device.
  • Current Consumption: Approx. 4 mA.
Applications: The V-lambda sensors are used in medical and biological research, weather forecasting, climate research, agriculture, and the automobile industry for measuring artificial lighting. The device complies with device class B as per DIN 5032 and is suitable for indoor use only.
Design and Functionality: The measuring head features a black, anodized aluminum housing and is cos-corrected. It operates with its own AD converter, ensuring measurement accuracy is unaffected by extension cables or the measuring device. The measuring range is divided into four segments for high-resolution measurements of small illuminances.
Product Variants: The digital measuring head for illuminance with a fixed 1.5 m cable and ALMEMO® D6 connector is available under order number FLAD03VL1.
Note: Technical specifications are subject to change.
See more

Catalog excerpts

FLAD03VL1-english-1

Technical data Measuring range V-lambda 1 lx to 200 klx ALMEMO® measuring ranges up to 650.00 lx up to 6500.0 lx up to 65000 lx up to 200.00 klx V-lambda radiation The spectral range of the visible light is referred to as V-lambda radiation and corresponds to the sensitivity of the human eye. The measured value is a measure for the perceived brightness. The wavelength range extends from the end of the UV spectrum at 400 nm to the beginning of the IR range at 720 nm with a maximum at 555 nm. The determined illuminance in “LUX” can directly be converted into the irradiance “W/ m2”. Measurements in this particular range have a great importance for the workplace design and lighting projects. V-lambda sensors are used in the field of medical and/or biological research, for weather information and forecasting systems, for climate research, for agriculture, and for the automobile industry respectively for measuring artificial lighting. The spectral sensitivity of the receiver is extremely well adapted to the sensitivity of the human eye and complies with the device class B as per DIN 5032. The measuring head FLAD 03 VL1 has a black, anodized aluminum housing. The measurement is cos corrected. The measuring head is only suitable for indoor usage. Digital measuring head with ALMEMO® D6 connector The measuring head works with its own AD converter. Used extension cables and the measuring device have no influence on the accuracy of the measurement. The entire measuring range is divided into 4 measuring ranges, so that, among other things, the smallest illuminances can be measured with a very high resolution. Sensor system Si / interf. filter Maximum spectral sensitivity 555 nm Switch-on time (Duty cycle) < 1 s Switch-off time < 1 s height approx. 29 mm Mounting 2 screws M2 ALMEMO® connection cable permanently connected cable 1.5 m with ALMEMO® D6 connector 04/2026 • We reserve the right to make technical changes. ALMEMO® D6 connector Refreshrate Stabilization time Supply voltage Current consumption 1.5 s for all channels 3 s (For data logger operation in sleep mode, a sleep delay of 3 s must be programmed) up to 6 V from the ALMEMO® device approx. 4 mA Variants (inci. works test certificate) Order no. Digital measuring head for illuminance, fixed cable, length 1.5 m, with ALMEMO® D6 connector FLAD03VL1

 Open the catalog to page 1

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Trigger cable

    3  Pages

  2. RTA5-english

    1  Page

  3. RTA6-english

    1  Page

  4. Cases

    1  Page

  5. ODBC-english

    4  Pages

  6. Web server

    4  Pages

  7. PIMEX-english

    4  Pages

  8. Thermo-wires

    3  Pages

  9. FIA20-english

    2  Pages

  10. MI30-english

    2  Pages

  11. MI40-english

    2  Pages

  12. Pitot Tubes

    2  Pages

  13. Force-english

    3  Pages

  14. Displacement

    2  Pages

  15. Speed

    1  Page

  16. Flow

    2  Pages

  17. Wind sensor

    2  Pages

  18. Comfort Index

    2  Pages

  19. Sound Level

    1  Page

  20. Moisture

    5  Pages

  21. pH-english

    4  Pages

  22. Conductivity

    2  Pages

  23. CO sensor

    1  Page

  24. Certificates

    8  Pages

  25. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.