FLA 613 VLK
2Pages

{{requestButtons}}

Catalog excerpts

FLA 613 VLK - 1

Optical radiation Technical data: Measuring range Spectral sensitivity Maximum spectral sensitivity Signal output Duty cycle Power supply • Measuring independent of direction - thanks to the probe head’s spherical characteristics • Weather-proof aluminum housing, with plastic globe • Suitable for universal use, inter alia for measuring in photostability tests according to various international standards and ICH guidelines (International Conference on Harmonization) • Spectral range of the probe head corresponds to the sensitivity of the human eye (V-lambda radiation). 2 screws, M4, in base plate Cable passage anodized aluminum Directional characteristic see diagram Linearity Absolute error Nominal temperature Operating temperature Ball diameter : 40 mm Overall height : 76 mm Type (including test protocol) Lux probe head for measuring luminous intensity, with spherical characteristic, including 1.5-meter cable and ALMEMO® connector UVA probe head FLA 613 UVAK Technical data: • Measuring independent of direction - thanks to the probe head’s spherical characteristics • Weather-proof aluminum housing, with plastic globe • Suitable for universal use, inter alia for measuring in photostability tests according to various international standards and ICH guidelines (International Conference on Harmonization) • Measuring head for measuring the UVA Measuring range 0 to approx. 50 W/m2 Spectral sensitivity 310 to 400 nm Maximum spectral sensitivity 355 nm Signal output 0 to 2 V Duty cycle <1 second Power supply via ALMEMO® connector +5 to +15 V Fastening 2 screws M4, in base plate at side Cable passage Housing anodized aluminum Diffuser PMMA (polymethyl methacrylate, acrylic) Ball PMMA (transparent to UV) Directional characteristic see diagram Linearity < 1% Absolute error < 10% Nominal temperature 22 ± 2 °C Operating temperature –20 to +60 °C Dimensions Ball diameter : 40 mm Overall height: 76 mm Weight approx. 100 grams Type (including test protocol) UVA probe head, with spherical characteristic, including 1.5-meter cable and ALMEMO® connector Factory calibration KL90xx radiation for sensor (see chapter Calibration certificates) 10/2013 • We reserve the right to make technical changes.

Open the catalog to page 1
FLA 613 VLK - 2

Illuminance measuring head FLA 603 VLx • High quality probe head for illuminance of light in lighting engineering or in sunlight and any place where DIN standards recommend the use of a class B luxmeter. • Spectral adaptation approximated to the photometric valuation function V(X) for photopic vision, class B, better than 5%. • Different measuring channels with different sensitivity. Optical radiation Technical data: Spectral adaptation: approxim. to photometric valuat. function V(l) for photopic vision, class B, better than 5% Humidity range: 10 to 90% (non-condensing) Illuminance...

Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Product Catalog

    348 Pages

  2. FPAD 36-3

    2 Pages

  3. FLD7 33-UVE

    2 Pages

  4. FHAD 46-DTC2

    1 Pages

  5. ALMEMO® 204

    3 Pages

  6. AMiR 7834

    6 Pages

  7. ALMEMO® D6

    1 Pages

  8. MH8D46

    2 Pages

  9. FHAD46-7

    1 Pages

  10. FHA 646 R

    1 Pages

  11. Thermo-wires

    3 Pages

  12. ALMEMO® 5690

    10 Pages

  13. Product Catalog

    329 Pages

  14. CO2 sensor

    2 Pages

  15. FLA623

    3 Pages

  16. Pitot Tubes

    2 Pages

  17. FHAD 36 Rx

    4 Pages

  18. ALMEMO ® D6

    2 Pages

  19. FHA 696 GF1

    1 Pages

  20. FLAD23CCT

    2 Pages

  21. AMiR 7838

    6 Pages

  22. FD 8214

    2 Pages

  23. FMD7-60

    3 Pages

  24. T 820-6

    2 Pages

  25. ALMEMO 2490

    2 Pages

  26. ALMEMO ® 5690

    10 Pages

  27. ALMEMO ®

    3 Pages

Archived catalogs