Electrical variablesDigital ALMEMO® D6 measuring module for AC voltage and AC current For acquiring the true root mean square (RMS) value of a sinusoidal AC signal. Sampling rate of 1000 mops. Overvoltage proof measuring input. Galvanically isolated up to 6 kV. For connection to all ALMEMO® V6 / V7 measuring instruments Applications ALMEMO® D6 measuring modules can be used for a wide variety of applications. Examples: • Inexpensive monitoring of several AC voltage signals with a large number of measuring modules • Monitoring the supply voltage and the current consumption of machines, motors, and other consumers. • Checking switches. • Monitoring of the electrical parameters voltage, in addition to the physical measured variables such as temperature, pressure, air flow, flow rate, etc. • Voltage and / or current measurement of 1-phase user (230 V AC) through a touch-proof Schuko-socket outlet adapter (accessory). The digital ALMEMO® D6 measuring module uses its own integrated AD converter. The overall accuracy of the measurement is independent from the ALMEMO® display unit/ data logger. The AC signal with sinusoidal curve progression is digitalized at the integrated AD converter at a high sampling rate and based on that, the true RMS value will be calculated continuously. At the same time, the frequency of the AC signal will be determined. The measured values are digitally interrogated by the ALMEMO® measuring device at the conversion rate of the measuring device. The ALMEMO® measuring instrument saves the measured values and the measuring software WinControl will display them graphically. The measuring input is overvoltage proof and galvanically isolated from the ALMEMO® measuring device. 11/2025 • We reserve the right to make technical changes. Technical data Input sockets: Safety sockets Sampling rate: 1 kHz internal AC signals U, I: only sinusoidal signals, no signals with phase angle control Response threshold U, I: Signal U and I > 1 % of fin. val. Operating range U, I, P: DC ... 250 Hz Measuring range U, I, P: see Types Resolution: see Types Internal resistance: see Types Measuring range frequency:20 to 250 Hz Resolution: 0.01 Hz Nominal conditions: Alternating signal: sinusoidal 50 Hz, Temperature drift: max. 0.003 %/K (30 ppm/K) (Storage temperature: -20 to +60 °C), 10 to 90 % Rh (non-condensing), maximum height above mean sea level: 2000 m Connecting cable: 2 m, permanently connected ALMEMO® D6-plug: for measuring channels, see Types, configuration via ALMEMO® device Supply voltage: 9 to 12 V via ALMEMO® device Current consumption: approx. 80 mA (plug and module)
Open the catalog to page 1Electrical variables Magnetic fastening Socket adapter: max. 230 V AC / 16 A Earthed socket for the consumer. 3 safety jacks: voltage, current, COM. Incl. short-circuit plug for current path. Housing: W 65 x H 120 mm Magnetic fastening Socket adapter ALMEMO® extension cable, length = 2 m (see chapter 6) ALMEMO® extension cable, length = 10 m (see chapter 6) Types Measuring module including touch proof connecting cable, ALMEMO® connection cable permanently connected to the ALMEMO® D6 plug AC voltage 2 ALMEMO® measuring channels: voltage, frequency Measuring range Resolution Overload 25 VRMS AC...
Open the catalog to page 2Electrical variablesFast digital ALMEMO® D7 measuring module for AC voltage / AC current / AC power For acquiring the true root mean square (RMS) value of a sinusoidal AC signal. Sampling rate of 1000 mops. Overvoltage proof measuring input. Galvanically isolated up to 6 kV. For connecting current ALMEMO® V7 measuring instruments, ALMEMO® 202-S, 204, 104, 710, 510, 809. Applications ALMEMO® D7 measuring modules can be used for a wide variety of applications. Examples: 11/2025 • We reserve the right to make technical changes. • Inexpensive monitoring of several AC voltage signals with a large...
Open the catalog to page 3ALMEMO® D7 Accessories Order no. Earthed socket for the consumer. 3 safety jacks: voltage, current, COM. Incl. short-circuit plug for current path. Housing: W 65 x H 120 mm 11/2025 • We reserve the right to make technical changes. Types Measuring module including touch proof connecting cable, ALMEMO® connection cable permanently connected to the ALMEMO® D7 plug 2 ALMEMO® measuring channels: voltage, frequency Measuring range Resolution 2 ALMEMO® measuring channels: current, frequency Measuring range Resolution Overload Input resistance Order no. maximum of 10 ARMS. For currents exceeding 10 ARMS,...
Open the catalog to page 4324 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
13 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
1 Page
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
4 Pages
2 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages