Catalog excerpts
Our new plug-in digital multi-sensor module - with its miniature design and extremely low energy consumption - combines the measurable variables - temperature, atmospheric humidity, and atmospheric pressure. It takes a complete reading of all these ambient parameters and can thus accurately determine all humidity-related and pressure-dependent variables, e.g. the frequently needed mixture ratio (r). It communicates its findings via an I2C interface; the user can selectively access individual sensor variables and data saved to the integrated EEPROM. Before leaving our factory the sensor module is adjusted and assigned an electronic identification code that can be read out on receipt of the appropriate command. The integrated EEPROM can be used to save the user‘s own adjustment data, fine tuning, or electronic ID data (ID number, comments text, etc.). Since the saved parameters are retained in the EEPROM, a multisensor module can only be exchanged or replaced with modules that are identically calibrated and have all the same data. The module is specially designed with very good thermal isolation to withstand temperature influence / thermal conduction and thus ensure that all variables are measured precisely. This system - unlike analog measured value processing - virtually excludes the risk of varying line lengths or disturbance factors adversely affecting the accuracy of measured results. Technical data Temperature range Accuracy Reproducibility Humidity range Accuracy Hysteresis Pressure range Accuracy Internal memory -40 to +85 °C +5 to +60 °C, typical ±0.2 K +5 to +60 °C, maximum 0.4 K -20 to +85 °C, maximum 0.7 K typical ±0.1 K 5.0 to 98.0 % RH 10 to 90 % RH, maximum ±1.8 % RH at 23 °C ±5 K 5 to 98 % RH, maximum ±4 % RH at 23 °C ±5 K typical ±1 % RH 300 to 1100 mbar ±2.5 mbar at 23 °C ±5 K I2C interface Data rate Sampling rate Electrical data Power supply Current consumption Energy consumption Connection 2.1 to 3.6 V, typical 3.3 V during measuring typical 310 µA in standby typical 0.35 µA during measuring typical 1.02 mW in standby typical 1.16 µW male strip connector, 4-pin, spacing 1.27 mm see pin assignment lead-free, halogen-free, and RoHS-compliant (restriction of hazardous substances) two-wire serial EEPROM 4 kbit (512 x 8 bit) Miniature multi-sensor module for measuring temperature, humidity, and pressure with integrated EEPROM 04/2016 • We reserve the right to make technical changes. Miniature multi-sensor module for measuring temperature, humidity, and pressure wi
Open the catalog to page 1All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures
-
Measuring instruments and sensors
372 Pages
-
Product Catalog
348 Pages
-
FPAD 36-3
2 Pages
-
Electrical variables
2 Pages
-
FLD7 33-UVE
2 Pages
-
Optical radiation ALMEMO® D7
2 Pages
-
FHAD 46-DTC2
1 Pages
-
ALMEMO® 2490-1L
1 Pages
-
ALMEMO® 204
3 Pages
-
AMiR 7834
6 Pages
-
ALMEMO® D6
1 Pages
-
ALMEMO® 470-1
4 Pages
-
ALMEMO® 1033-2
1 Pages
-
MH8D46
2 Pages
-
FHAD46-7
1 Pages
-
FHA 646 R
1 Pages
-
Connector for thermocouples
1 Pages
-
Glass thermometer
1 Pages
-
Pt100 cable sensor
1 Pages
-
Thermo-wires
3 Pages
-
ALMEMO® 1030
2 Pages
-
ALMEMO® 8590 / 8690
2 Pages
-
ALMEMO® 5690
10 Pages
-
ALMEMO® 2890
2 Pages
-
ALMEMO® 2690
2 Pages
-
ALMEMO® 2590
3 Pages
-
ALMEMO® 2470
3 Pages
-
ALMEMO ® 8036
3 Pages
-
ALMEMO ® 500
3 Pages
-
Product Catalog
329 Pages
-
D6 connectors
1 Pages
-
OCX Win Control
1 Pages
-
ALMEMO® Control
4 Pages
-
CO2 sensor
2 Pages
-
conductivity D7
2 Pages
-
FLA623
3 Pages
-
Comfort Index
2 Pages
-
Modules for DC
1 Pages
-
Pressure sensors FDA602L
1 Pages
-
D6 Anemometer
1 Pages
-
Pitot Tubes
2 Pages
-
Digital sensor for humidity
3 Pages
-
FHAD 36 Rx
4 Pages
-
ALMEMO® 1036
2 Pages
-
ALMEMO® 1020
3 Pages
-
ALMEMO® 2490
2 Pages
-
ALMEMO® 2450
2 Pages
-
General accessories
3 Pages
-
Instrument Cases
1 Pages
-
ALMEMO ® Control : Software
4 Pages
-
Software ALMEMO ® View
1 Pages
-
ALMEMO ® D6
2 Pages
-
Pressure FDAD 12 SA
1 Pages
-
Sound Level MA 86193
1 Pages
-
FHA 696 GF1
1 Pages
-
Heat Flow Plates FQAx
2 Pages
-
Moisture Sensor FHA 696 MF
4 Pages
-
Radiation probe FLA 623 x
3 Pages
-
FLA 613 VLK
2 Pages
-
FLAD23CCT
2 Pages
-
Sensor FYAD 00 CO2B10
2 Pages
-
Transducer FYA600O3
1 Pages
-
AMiR FIA 844 s
2 Pages
-
AMiR 7838
6 Pages
-
FD 8214
2 Pages
-
FMD7-60
3 Pages
-
T 820-6
2 Pages
-
ALMEMO ® 202
2 Pages
-
ALMEMO 2490
2 Pages
-
ALMEMO ® 2470
3 Pages
-
ALMEMO ® 2690-8A
2 Pages
-
ALMEMO ® 5690
10 Pages
-
ALMEMO ® 1030-2
1 Pages
-
ALMEMO ® 1036-2
2 Pages
-
ALMEMO transmiter 2450/2490
2 Pages
-
ALMEMO ® 4390-2
1 Pages
-
ALMEMO ® 809
2 Pages
-
ALMEMO ®
3 Pages
Archived catalogs
-
Infrared Measuring Technique
24 Pages
-
Gas concentration in air
6 Pages
-
Water Analysis
8 Pages