Differential pressure transmitter FDA 602 D • This measures the differential pressure in liquid and gaseous media indirectly using two absolute pressure sensors. • This makes it less expensive but more robust with respect to asymmetrical overload. • The differential pressure range should be at least 5 % of the standard pressure range. • Each side of the sensor incorporates two pressure connections. The transmitters can thus be used easily and conveniently in pressure pipes. • It incorporates a high-speed, high-precision microprocessor. • All reproducible errors affecting the pressure sensors, i.e. involving non-linearity and temperature dependency, can be completely eliminated by means of mathematical error compensation. Medium-pressure version Technical Data: Standard pressure range (maximum measurable pressure per pressure connection), overload, differential pressure range. See versions listed below. Storage / operating temperature -40 to +100 °C Compensated standard range -10 to +80 °C Error margin <0.05 % typical, <0.1 % max. of final value to standard pressure range (linearity + hysteresis + reproducibility + temperature error) Pressure connections G1/4“ thread, female Material in contact with medium Stainless steel, 316L, ALMEMO® connector Output 0 to 2 V Electrical connection Binder plug, including ALMEMO® connecting cable, 2 meters with shielded cable Protective class IP 65 Low-pressure version 475 grams Medium-pressure version 750 grams 11/2025 • We reserve the right to make technical changes. Types Differential pressure transmitter, including ALMEMO® cable, 2 meters Standard pressure range OverloadAbsolute pressureLow-pressure version 3 bar 10 bar Differential pressure range Please indicate final value Final value 0.2 to 3 bar Final value 0.5 to 10 bar Final value 1.25 to 25 bar Order no. FDA602D01FDA602D02FDA602D03FDA602D10 DAkkS accredited calibration or factory calibration KD9xxx pressure for sensor or measuring chain (sensor + device), see chapter „Calibration certificates“. DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025.
Open the catalog to page 1324 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
13 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
1 Page
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
4 Pages
2 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages