Catalog excerpts
Water analysis Digital probes for measuring conductivity FYD 741 LFE01 and FYD 741 LFP with ALMEMO® D7 plug Just one single probe for measuring conductivity from very low (10 µS/cm) up to very high levels (500 mS/cm) 4-contact graphite electrode with high linearity across the whole measuring range Integrated NTC sensor for temperature compensation of measured conductivity values Suitable for the latest ALMEMO® V7 devices, including professional measuring instrument ALMEMO® 202 and precision measuring instrument ALMEMO® 710. Technical data and functions The digital conductivity probe provides this high level of precision irrespective of any extension cables used and of any processing in the ALMEMO® V7 display device / data logger. Overall accuracy is determined exclusively by the conductivity electrode and the ALMEMO® D7 plug. All parameters for the sensor can be programmed end-to-end via the programming menu on the ALMEMO® V7 measuring instrument. The desired measuring range can be selected and temperature compensation can be activated or deactivated. The temperature coefficient of the solution to be measured, if known, can also be programmed. The probe is delivered already adjusted and ready-to-use. The electrode‘s measured cell constant can also be entered, if so required, and / or the probe can be adjusted using a reference solution. Common technical data FYD 741 LFE01 and FYD 741 LFP ALMEMO® D7 plug with A/D converter 10/2016 • We reserve the right to make technical changes. Measuring method Electrical conductivity measurement with AC voltage (approx. 1 kHz) Measuring ranges Range DLF1 Range DLF2 Range DLF3 Range NTC up to maximum 500.00 µS/cm Resolution 0.01 µS/cm up to 50.000 mS/cm Resolution 0.001 mS/cm (factory default settings) with FYD 741 LFE01 up to 500.00 mS/cm with FYD 741 LFP up to 200.00 mS/cm Resolution 0.01 mS/cm Resolution 0.01 K Temperature compensation ither automatic or non-compensated e Accessories Reference solution for monitoring / calibration Conductivity 147 µS/cm, Container 250 ml Conductivity 2.77 mS/cm, Container 250 ml Conductivity 12.88 mS/cm, Container 250 ml Conductivity 111.8 mS/cm, Container 250 ml Temperature coefficient Natural surface water or linear in range 0.00 to 9,99 Linearization NTC Calculated error-free (not an approximation) Nominal temperature Temperature drift Refresh time Sleep mode on the device possible with wakeup delay of 5 seconds Supply voltage 6 to 13 VDC, from ALMEMO® device (sensor supply voltage) Current consumption
Open the catalog to page 1Water analysis ALMEMO® D7 Digital probe for measuring conductivity FYD 741 LFE01 Probe for process applications Probe for laboratory applications General description and common technical data see previous page General description and common technical data see previous page Technical data FYD 741 LFE01 Uses Conductivity Temperature Pressure Laboratory applications 10 µS/cm up to 200 mS/cm, on demand up to 500 mS/cm 0 to +80 °C Ambient pressure (unpressurized) 4-contact graphite electrode electrically connected to the power supply (ALMEMO® device ground) Electrode type 4-contact graphite...
Open the catalog to page 2All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures
-
Measuring instruments and sensors
372 Pages
-
Product Catalog
348 Pages
-
FPAD 36-3
2 Pages
-
Electrical variables
2 Pages
-
FLD7 33-UVE
2 Pages
-
Optical radiation ALMEMO® D7
2 Pages
-
FHAD 46-DTC2
1 Pages
-
ALMEMO® 2490-1L
1 Pages
-
ALMEMO® 204
3 Pages
-
AMiR 7834
6 Pages
-
ALMEMO® D6
1 Pages
-
ALMEMO® 470-1
4 Pages
-
ALMEMO® 1033-2
1 Pages
-
MH8D46
2 Pages
-
FHAD46-7
1 Pages
-
FHA 646 R
1 Pages
-
Connector for thermocouples
1 Pages
-
Glass thermometer
1 Pages
-
Pt100 cable sensor
1 Pages
-
Thermo-wires
3 Pages
-
ALMEMO® 1030
2 Pages
-
ALMEMO® 8590 / 8690
2 Pages
-
ALMEMO® 5690
10 Pages
-
ALMEMO® 2890
2 Pages
-
ALMEMO® 2690
2 Pages
-
ALMEMO® 2590
3 Pages
-
ALMEMO® 2470
3 Pages
-
ALMEMO ® 8036
3 Pages
-
ALMEMO ® 500
3 Pages
-
Product Catalog
329 Pages
-
D6 connectors
1 Pages
-
OCX Win Control
1 Pages
-
ALMEMO® Control
4 Pages
-
CO2 sensor
2 Pages
-
FLA623
3 Pages
-
Comfort Index
2 Pages
-
Modules for DC
1 Pages
-
Pressure sensors FDA602L
1 Pages
-
D6 Anemometer
1 Pages
-
Pitot Tubes
2 Pages
-
Digital sensor for humidity
3 Pages
-
FHAD 36 Rx
4 Pages
-
ALMEMO® 1036
2 Pages
-
ALMEMO® 1020
3 Pages
-
ALMEMO® 2490
2 Pages
-
ALMEMO® 2450
2 Pages
-
General accessories
3 Pages
-
Instrument Cases
1 Pages
-
ALMEMO ® Control : Software
4 Pages
-
Software ALMEMO ® View
1 Pages
-
ALMEMO ® D6
2 Pages
-
Pressure FDAD 12 SA
1 Pages
-
Sound Level MA 86193
1 Pages
-
FHA 696 GF1
1 Pages
-
Heat Flow Plates FQAx
2 Pages
-
Moisture Sensor FHA 696 MF
4 Pages
-
Radiation probe FLA 623 x
3 Pages
-
FLA 613 VLK
2 Pages
-
FLAD23CCT
2 Pages
-
Sensor FYAD 00 CO2B10
2 Pages
-
Transducer FYA600O3
1 Pages
-
AMiR FIA 844 s
2 Pages
-
AMiR 7838
6 Pages
-
FD 8214
2 Pages
-
FMD7-60
3 Pages
-
EEPROM FH0D 46- C
1 Pages
-
T 820-6
2 Pages
-
ALMEMO ® 202
2 Pages
-
ALMEMO 2490
2 Pages
-
ALMEMO ® 2470
3 Pages
-
ALMEMO ® 2690-8A
2 Pages
-
ALMEMO ® 5690
10 Pages
-
ALMEMO ® 1030-2
1 Pages
-
ALMEMO ® 1036-2
2 Pages
-
ALMEMO transmiter 2450/2490
2 Pages
-
ALMEMO ® 4390-2
1 Pages
-
ALMEMO ® 809
2 Pages
-
ALMEMO ®
3 Pages
Archived catalogs
-
Infrared Measuring Technique
24 Pages
-
Gas concentration in air
6 Pages
-
Water Analysis
8 Pages