Comfort Index
1 /2Pages

Comfort Index

Comfort Index
1 /2Pages

Catalog excerpts

Comfort Index -1

• Thermal comfort and air-conditioning calculations using WinControl software with add-on module for comfort index measurement as per DIN ISO 7730 and DIN EN 13779 (formerly DIN 1946) • Independent measuring sequence in real-time mode • Various display and output options Real-time mode, memory access to offline measuring operations • Graphical presentation of measured data and calculated data in a format with data export options • Comprehensive, clear, meaningful evaluation. It is possible with this measuring setup to measure all the physical parameters needed for assessing and evaluating thermal comfort simultaneously on three levels. It reliably evaluates the performance of heating and ventilating systems. The data acquired from the series of measuring operations for operative temperature (globe temperature), room temperature, and room air flow and humidity, and the necessary input parameters (e.g. clothing factor, activity level, mechanical output) is used together to calculate the PMV (predicted mean vote) and PPD (predicted percent dissatisfied) values (as per DIN ISO 7730) and the degree of turbulence ( as per DIN EN 13779, formerly DIN 1946 Part 2); these values are calculated either online or offline using the AMR WinControl software in conjunction with the add-on module for comfort index measurement. The averaging number is preset at 200 measuring points but this is variable and can be modified. The PMV and pPd values and the degree of turbulence can be displayed and documented in y/t or x/y diagrams either each one separately or together with other measurable variables. A software wizard is available to guide the user step-by-step through the various settings. If measuring is started online, the first value is indicated after completion of the first 200 measuring operations (as per DIN ISO 7730). These values continue to be calculated, updated, and displayed, and -optionally - also saved and / or exported (see Chapter 05). 03/2026 • We reserve the right to make technical changes. Types (sensor set for one level) Globe thermometer Digital sensors for humidity, temperature, atmospheric Pressure Thermo-anemometer, omnidirectional up to 1 m/s Stand for measuring operations at heights of 0.1 to 1.7 meters, including 1 set of instrument holders for 1 level (traverse including traverse holder and sensor fastening), including carry case ZB1001PPD1 Set of instrument holders for extra levels (as above) ZB1001MH1 optional for assessing air quality Digital carbon dioxide sensor to 5.000 ppm, with handle FYAD00CO2M3B05 Device selection ALMEMO® 2690-8A (new variant) hand-held data logger, 5 inputs, including mains unit and data cable, USB can be used for 1 measuring level MA26908AKSU ALMEMO® 710 data logger, 10 inputs, including mains unit, USB data cable can be used for 3 measuring levels MA710 PC link via Ethernet, RS232, or wireless with radio see Chapter 04, ALMEMO® networking technology. WinControl for 20 measuring points / 1 device SW5600WC1 including additional module for comfort index measurement SW5600WCZM1 Carry case, universal, spacious, robust, for globe thermometer, humidity sensor, and data logger Exterior dimensions (WxHxD) approx. 51 x 35 x 30 cm ZB5600TK3 DAkkS accredited calibration or factory calibration temperature, humidity, air flow, carbon dioxide for sensor, see chapter „Calibration certificates“. DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025.

 Open the catalog to page 1
Comfort Index -2

Application Range The wet bulb globe temperature (WBGT) is the decisive parameter for evaluating the work stress at heat-exposed working places and the operation and cool-off times involved. Temperature, radiation and relative humidity are determined by measuring the dry temperature, the natural humid temperature of a psychrometer and the globe temperature of a globe thermometer. These are all combined as WbGt. For WBGT measurements the use of a psychrometer with a disengageable ventilator is compulsory Globe thermometer: matt black copper globe with suspension Types Order no. Globe thermometer...

 Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. ALMEMO® 2470

    3  Pages

  2. ALMEMO® 2890

    2  Pages

  3. ALMEMO® 104

    3  Pages

  4. ALMEMO® 710

    3  Pages

  5. ALMEMO® 500

    4  Pages

  6. ALMEMO® 510

    3  Pages

  7. ALMEMO® 809

    2  Pages

  8. ALMEMO® 5690

    8  Pages

  9. ALMEMO® 1020

    2  Pages

  10. ALMEMO® 1030

    2  Pages

  11. ALMEMO® 1033

    2  Pages

  12. ALMEMO® 1036

    2  Pages

  13. ALMEMO® 8036

    3  Pages

  14. RTA5

    1  Page

  15. RTA6

    1  Page

  16. Cases

    1  Page

  17. WinControl

    13  Pages

  18. Thermo-wires

    3  Pages

  19. FIAD43

    2  Pages

  20. FIA844

    2  Pages

  21. AMiR 7843

    2  Pages

  22. AMiR 7834

    6  Pages

  23. FHAD 36 Rx

    4  Pages

  24. FHA 646 R

    1  Page

  25. FHAD46-7

    1  Page

  26. Psychrometer

    1  Page

  27. MH8D46

    2  Pages

  28. Pitot Tubes

    2  Pages

  29. Force

    3  Pages

  30. Displacement

    2  Pages

  31. Vibration

    2  Pages

  32. Speed

    1  Page

  33. Flow

    2  Pages

  34. Wind sensor

    2  Pages

  35. FLD733UVE

    2  Pages

  36. Sound Level

    1  Page

  37. Moisture

    5  Pages

  38. Tensiometer

    1  Page

  39. FLAD03VL1

    1  Page

  40. FLA623

    3  Pages

  41. VLambda

    1  Page

  42. FLD703UVE

    2  Pages

  43. Luminance

    1  Page

  44. pH

    4  Pages

  45. Conductivity

    2  Pages

  46. CO sensor

    1  Page

  47. Certificates

    7  Pages

  48. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.