CO2 sensor FYAD 00-VCO2B200
1 /1Page

CO2 sensor FYAD 00-VCO2B200

CO2 sensor FYAD 00-VCO2B200
1 /1Page

Catalog excerpts

CO2 sensor FYAD 00-VCO2B200-1

Gas concentration in the air Digital carbon dioxide sensor FYAD 00-VCO2B200. Range up to 20 % CO2, with digital ALMEMO® plug. • Digital carbon dioxide sensor for concentrations in the percentage range. • Applications in biotechnology, e.g. in bio-incubators and in the food industry, e.g. in cold stores for the storage and transportation of fruit and vegetables. • Robust housing for operation in a wide temperature and humidity range. • Protection of the sensor against contamination with replaceable filter. • All calibration and sensor data are stored in the carbon dioxide sensor. • Temperature compensation of the sensor element with the built-in temperature sensor. • Automatic air pressure compensation with digital air pressure sensor, built into the ALMEMO® connector. • Long-term measurements with ALMEMO® data logger in continuous operation; no sleep mode possible. • 3 measuring channels: Carbon dioxide concentration (compensated with the measured temperature and the measured air pressure), carbon dioxide concentration not compensated (for own compensation in the measuring software with external measured variables temperature and air pressure), air pressure. Technical Data Digital carbon dioxide (CO2) sensor Measuring principle non-dispersive infrared sensor (NDIR) based on silicon, measurement at two wavelengths (ratiometric) Measuring range 0 … 20 % CO2 03/2026 • We reserve the right to make technical changes. Operating conditions -40 … 60 °C, 500 … 1100 mbar compensated (max. 1.5 bar), 0 to 95 % r.H., non-condensing Materials Sensor housing PBT plastic Filter PTFE membrane, PBT plastic grid Dimensions Diameter 25 mm Total length of the sensor: 84 mm without plug Nominal conditions 25 °C, 1013 mbar Sensor connection Temperature dependence Measuring range CO2 compensated at 5 % CO2 ±0.05 % CO2 in range 0 … 50 °C at 0 … 20 % CO2 ±0.045 % of meas. value / °C in range -40 … 60 °C ALMEMO® plug-in connection cable, 1.5 m cable, with digital ALMEMO® plug Air pressure dependence Measuring range CO2 compensated at 5 % CO2 ±0.05 % CO2 in range 700 … 1100 mbar at 0 … 20 % CO2 ±0.015 % of meas. value / mbar in range 500 … 1100 mbar Response time t90 < 1 min with standard filter Warm-up time 4 min after switching on for full accuracy Measuring interval 2 s (current value) Type (including factory test certificate) Built-in connector, digital output Power supply 12 V DC, max. 0.5 W via ALMEMO® plug Digital atmospheric pressure sensor (integrated in ALMEMO® plug) Measuring range 700 … 1100 mbar Accuracy ± 2.5 mbar (23 °C ± 5 K) Digital ALMEMO® plug Refresh rate 2 sec for all channels Supply voltage 12 V DC from the ALMEMO® device Current consumption typ. 40 mA, starting current typ. 120 mA Digital carbon dioxide sensor up to 20 % CO2, with digital ALMEMO® cable plug, integrated digital atmospheric pressure sensor Accredited calibration KY9621D, carbon dioxide concentration, for digital sensor FYAD00VCO2B200, see chapter „Calibration Certificates“. The accredited calibration meets all the require

 Open the catalog to page 1

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. ALMEMO® 2470

    3  Pages

  2. ALMEMO® 2890

    2  Pages

  3. ALMEMO® 104

    3  Pages

  4. ALMEMO® 710

    3  Pages

  5. ALMEMO® 500

    4  Pages

  6. ALMEMO® 510

    3  Pages

  7. ALMEMO® 809

    2  Pages

  8. ALMEMO® 5690

    8  Pages

  9. ALMEMO® 1020

    2  Pages

  10. ALMEMO® 1030

    2  Pages

  11. ALMEMO® 1033

    2  Pages

  12. ALMEMO® 1036

    2  Pages

  13. ALMEMO® 8036

    3  Pages

  14. RTA5

    1  Page

  15. RTA6

    1  Page

  16. Cases

    1  Page

  17. WinControl

    13  Pages

  18. Thermo-wires

    3  Pages

  19. FIAD43

    2  Pages

  20. FIA844

    2  Pages

  21. AMiR 7843

    2  Pages

  22. AMiR 7834

    6  Pages

  23. FHAD 36 Rx

    4  Pages

  24. FHA 646 R

    1  Page

  25. FHAD46-7

    1  Page

  26. Psychrometer

    1  Page

  27. MH8D46

    2  Pages

  28. Pitot Tubes

    2  Pages

  29. Force

    3  Pages

  30. Displacement

    2  Pages

  31. Vibration

    2  Pages

  32. Speed

    1  Page

  33. Flow

    2  Pages

  34. Wind sensor

    2  Pages

  35. FLD733UVE

    2  Pages

  36. Sound Level

    1  Page

  37. Moisture

    5  Pages

  38. Tensiometer

    1  Page

  39. FLAD03VL1

    1  Page

  40. FLA623

    3  Pages

  41. VLambda

    1  Page

  42. FLD703UVE

    2  Pages

  43. Luminance

    1  Page

  44. pH

    4  Pages

  45. Conductivity

    2  Pages

  46. CO sensor

    1  Page

  47. Certificates

    7  Pages

  48. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.