1. Catalogs
  2. Ahlborn Mess- und Regelungstechnik GmbH
  3. CO2 measurement for indoor air quality

CO2 measurement for indoor air quality

CO2 measurement for indoor air quality

CO2 measurement for indoor air quality

Product catalog summary
Overview: The document provides technical specifications and functionalities of the Digital Carbon Dioxide Sensor FYAD 00-CO2M2 / M3, designed for assessing indoor air quality in various environments such as classrooms, healthcare facilities, and public transportation.
Specifications:
  • CO2 Measurement: Utilizes a 2-beam infrared sensing element with non-dispersive infrared technology (NDIR) for measuring CO2 concentrations up to 5000 ppm.
  • Accuracy: ±(50 ppm +3% of measured value) under nominal conditions of 25°C and 1013 mbar.
  • Response Time: Initialization time is 15 seconds with a response time (t63) of 140 seconds.
  • Measuring Interval: Fixed at 15 seconds, using an exponential moving average over 60 seconds.
  • Operating Conditions: FYAD 00-CO2M3B05 operates between -40 to 60°C, while FYAD 00-CO2M2B05 operates between -10 to 60°C, with a humidity range of 0-95% r.h. (non-condensing).
Functions:
  • Simultaneous measurement of air temperature and pressure for comprehensive air quality assessment.
  • Automatic compensation for temperature and pressure variations.
  • Unique auto-calibration procedure to compensate for aging effects without fresh air supply.
  • Low power consumption suitable for long-term measurements with ALMEMO® data logger in sleep mode.
Components:
  • Filter Cap: Made of PTFE, protects against dust and dirt.
  • Sensor Tube: Stainless steel for FYAD 00-CO2M3B05, with specific dimensions for durability.
  • Connection: FYAD 00-CO2M3B05 features a permanently connected cable, while FYAD 00-CO2M2B05 is mounted directly on the ALMEMO® connector.
Calibration and Certification: The sensor can be calibrated by a DAkkS accredited laboratory, and it meets the requirements of DIN EN ISO/IEC 17025 for test equipment.
Applications: Suitable for demand-oriented ventilation checks in various settings, ensuring optimal air quality and comfort.
See more

Catalog excerpts

CO2 measurement for indoor air quality-1

Digital carbon dioxide sensor FYAD 00-CO2M2 / M3 for assessing the indoor air quality. With ALMEMO® D6 connector. Technical data and functions • Calibrated reference system for CO2 concentration for checking CO2 sensors permanently installed in the building management system (BMS) / room ventilation system (AHU). • Digital sensor with integrated signal processor. All calibration and sensor data are stored in the sensor. • Unique auto-calibration procedure (without fresh air supply): aging effects are automatically compensated. • With filter cap to protect against dust and dirt. • Automatic compensation with built-in digital temperature and barometric pressure sensor. • Low power consumption. Long-term measurements with ALMEMO® data logger in sleep mode; only for current instrument types with sleep delay. • 3 primary measurement channels (real measured variables): carbon dioxide concentration, air temperature, air pressure. 03/2026 • We reserve the right to make technical changes. • Assessment of air quality for checking demand-oriented ventilation in recreation and work rooms, including classrooms, lecture halls, day care centers, meeting rooms, event rooms, production halls, health care facilities, public transportation. • In combination with an ALMEMO® data logger, the measured values are continuously recorded with date, time. Based on the stored data, a differentiated analysis of the air quality during the room usage times is possible. • Simultaneous measurement of air temperature as a criterion for assessing the quality of stay (comfort) in the rooms. concentration • Quantitative measurement of CO2 in ppm. Differentiated decision for concentrations near the quality levels 1000 ppm and 2000 ppm. On request: calibration of the sensor (traceable) by a DAkkS accredited cal

 Open the catalog to page 1
CO2 measurement for indoor air quality-2

Room Air ConditionsTechnical Data Sensor: 2-beam infrared sensing element. Non-dispersive infrared technology _(NDIR)._ Automatic compensation of pressure and temperature dependence of CO2 measurement with the built-in sensors. Accuracy: ±(50 ppm +3 % of measured value) Nominal conditions: 25 °C, 1013 mbar Switch-on time (initialization): 15 s Response time t63: 140 s Measuring interval: fixed 15 s as exponential moving average over 60 s (= 4 instantaneous values 15 s). FYAD 00-CO2M3B05: permanently connected cable 2 m with ALMEMO® plug FYAD 00-CO2M2B05: sensor mounted directly on ALMEMO® connector...

 Open the catalog to page 2

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Trigger cable

    3  Pages

  2. RTA5-english

    1  Page

  3. RTA6-english

    1  Page

  4. Cases

    1  Page

  5. ODBC-english

    4  Pages

  6. Web server

    4  Pages

  7. PIMEX-english

    4  Pages

  8. Thermo-wires

    3  Pages

  9. FIA20-english

    2  Pages

  10. MI30-english

    2  Pages

  11. MI40-english

    2  Pages

  12. Pitot Tubes

    2  Pages

  13. Force-english

    3  Pages

  14. Displacement

    2  Pages

  15. Speed

    1  Page

  16. Flow

    2  Pages

  17. Wind sensor

    2  Pages

  18. Comfort Index

    2  Pages

  19. Sound Level

    1  Page

  20. Moisture

    5  Pages

  21. pH-english

    4  Pages

  22. Conductivity

    2  Pages

  23. CO sensor

    1  Page

  24. Certificates

    8  Pages

  25. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.