Overview: This document provides technical specifications and applications for the Carbon Monoxide Probe ADOS 592 TOX and the Oxygen Probe FYA600O2, used for measuring gas concentrations in various environments.
Carbon Monoxide Probe ADOS 592 TOX:
  • Applications: Used for measurement, control, and warnings in garages and workplaces to monitor air quality against maximum allowable concentration (MAC) values.
  • Measuring Principle: Electrochemical reaction.
  • Specifications:
    • Zero point error: < 10 ppm CO
    • Gauge reading balance: < 3 ppm CO
    • Error of measurement value: ±3% of full scale value
    • Settling time t90: < 60 s
    • Operating conditions: –10 to +40 °C, 15 to 90% r.H. non-condensing
    • Life span: Approximately 2 years
    • Output: 4 ... 20 mA on ALMEMO® connector
  • Types and Order Numbers:
    • 0 ... 150 ppm: FYA600COB1
    • 0 ... 300 ppm: FYA600COB2
    • 0 ... 5000 ppm: FYA600COB3
    • 0 ... 5 Vol.%: FYA600COB4
Oxygen Probe FYA600O2:
  • Applications: Suitable for air conditioning systems, air purifiers, oxygen rectifiers, greenhouses, and oxygen incubators.
  • Measuring Principle: Electrochemical cell.
  • Specifications:
    • Measuring range: 1 ... 100% O2, linear
    • Accuracy: 1% O2
    • Response time: < 40 s
    • Operating life: 2 years in 20.9% O2
    • Temperature range: –20 to +50 °C
    • Temperature compensation: Effective in range –10 to +40 °C
  • Order Number: FYA600O2
Additional Information:
  • Both probes include a 1.5 m connecting cable.
  • Correction values can be stored in the ALMEMO® connector plug to compensate for natural ageing of the probes.
  • Technical changes may be made without notice.
See more

Catalog excerpts

CO sensor-1

Carbon Monoxide Probe ADOS 592 TOX Gas Concentration in the Air • Applications: For measurement, control and warnings in garages, for monitoring the air quality with respect to the maximum allowable concentration at work places (MAC value, e.g. in laboratories and engine test benches) ! Operation with the device in SLEEP mode is not possible! Technical Data Measuring principle: electrochemical reaction Measuring range: see types Zero point error: < 10 ppm CO Gauge reading balance: < 3 ppm CO Error of meas. value: ±3 % of full scale value Zero point drift: < 2 % (1 year) Linearity: < 2 % of full scale value Transverse sensitivity: < 2 % by integrated filter Nominal conditions: 20 °C, 50 % r.H., 1013 mbar Operating conditions: -10 to +40 °C, Sensor in range temperature compensated > 15 to 90 % r.H. non-condensing Life span of the meas. cell: approx. 2 years typical Output: 4 ... 20 mA on ALMEMO® connector Supply voltage: 24 V via ALMEMO® connector Dimensions of meas. head: 0 80 mm, height 80 mm Weight: 600 g Connecting cable: 1.5 m, with ALMEMO® connector Types (incl. factory test certificate) Order no. Carbon monoxide sensor including connecting cable 1.5 m long for CO measurements in air range: 0 ... 300 ppm range: 0 ... 5000 ppm range: 0 ... 5 Vol.% • Examples from the range of applications: Measurements in air conditioning systems, air purifiers, oxygen rectifiers, greenhouses and oxygen incubators. ! A correction value can be stored in the ALMEMO® con nector plug to compensate for the natural ageing of the probes, so optimum output characteristics can be ensured for the whole operating life. 11/2025 • We reserve the right to make technical changes. Technical Data Measuring principle: electrochemical cell Signal drift: < 2 % signal/month (typ. < 5 % over operating life) Offset voltage at 20 °C: < 20 mV Oxygen sensor including connecting cable 1.5 m long Operating life:_2 years, if operated in 20.9 % O2 Nominal conditions: 20 °C, 50 % rH, 1013 mbar Temperature compensation: effective in range -10 to +40 °C Pressure range: atm. pressure ±10 % Relative humidity: 0 to 99 % non-condensing Connecting cable: adapter cable 1.5 m long Oxygen sensor ALMEMO® connecting cable

 Open the catalog to page 1

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Trigger cable

    3  Pages

  2. RTA5-english

    1  Page

  3. RTA6-english

    1  Page

  4. Cases

    1  Page

  5. ODBC-english

    4  Pages

  6. Web server

    4  Pages

  7. PIMEX-english

    4  Pages

  8. Thermo-wires

    3  Pages

  9. FIA20-english

    2  Pages

  10. MI30-english

    2  Pages

  11. MI40-english

    2  Pages

  12. Pitot Tubes

    2  Pages

  13. Force-english

    3  Pages

  14. Displacement

    2  Pages

  15. Speed

    1  Page

  16. Flow

    2  Pages

  17. Wind sensor

    2  Pages

  18. Comfort Index

    2  Pages

  19. Sound Level

    1  Page

  20. Moisture

    5  Pages

  21. pH-english

    4  Pages

  22. Conductivity

    2  Pages

  23. Certificates

    8  Pages

  24. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.