CO sensor
1 /1Page

CO sensor

CO sensor
1 /1Page

Catalog excerpts

CO sensor -1

Carbon Monoxide Probe ADOS 592 TOX • Applications: For measurement, control and warnings in garages, for monitoring the air quality with respect to the maximum allowable concentration at work places (MAC value, e.g. in laboratories and engine test benches) ! Operation with the device in SLEEP mode is not possible! Technical Data Measuring principle: electrochemical reaction Measuring range: see types Zero point error: < 10 ppm CO Gauge reading balance: < 3 ppm CO Error of meas. value: ±3 % of full scale value Zero point drift: < 2 % (1 year) Linearity: < 2 % of full scale value Transverse sensitivity: < 2 % by integrated filter Nominal conditions: 20 °C, 50 % r.H., 1013 mbar Operating conditions: -10 to +40 °C, Sensor in range temperature compensated > 15 to 90 % r.H. non-condensing Life span of the meas. cell: approx. 2 years typical Output: 4 ... 20 mA on ALMEMO® connector Supply voltage: 24 V via ALMEMO® connector Dimensions of meas. head: 0 80 mm, height 80 mm Weight: 600 g Connecting cable: 1.5 m, with ALMEMO® connector 11/2025 • We reserve the right to make technical changes. Types (incl. factory test certificate) Order no. Carbon monoxide sensor including connecting cable 1.5 m long for CO measurements in air range: 0 ... 300 ppm range: 0 ... 5000 ppm range: 0 ... 5 Vol.% • Examples from the range of applications: Measurements in air conditioning systems, air purifiers, oxygen rectifiers, greenhouses and oxygen incubators. ! A correction value can be stored in the ALMEMO® connector plug to compensate for the natural ageing of the probes, so optimum output characteristics can be ensured for the whole operating life. Technical Data Measuring principle: electrochemical cell Signal drift: < 2 % signal/month (typ. < 5 % over operating life) Offset voltage at 20 °C: < 20 mV Operating life:_2 years, if operated in 20.9 % O2 Nominal conditions: 20 °C, 50 % rH, 1013 mbar Temperature compensation: effective in range -10 to +40 °C Pressure range: atm. pressure ±10 % Relative humidity: 0 to 99 % non-condensing Connecting cable: adapter cable 1.5 m long Oxygen sensor ALMEMO® connecting cable Oxygen sensor including connecting cable 1.5 m long

 Open the catalog to page 1

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. ALMEMO® 2470

    3  Pages

  2. ALMEMO® 2890

    2  Pages

  3. ALMEMO® 104

    3  Pages

  4. ALMEMO® 710

    3  Pages

  5. ALMEMO® 500

    4  Pages

  6. ALMEMO® 510

    3  Pages

  7. ALMEMO® 809

    2  Pages

  8. ALMEMO® 5690

    8  Pages

  9. ALMEMO® 1020

    2  Pages

  10. ALMEMO® 1030

    2  Pages

  11. ALMEMO® 1033

    2  Pages

  12. ALMEMO® 1036

    2  Pages

  13. ALMEMO® 8036

    3  Pages

  14. RTA5

    1  Page

  15. RTA6

    1  Page

  16. Cases

    1  Page

  17. WinControl

    13  Pages

  18. Thermo-wires

    3  Pages

  19. FIAD43

    2  Pages

  20. FIA844

    2  Pages

  21. AMiR 7843

    2  Pages

  22. AMiR 7834

    6  Pages

  23. FHAD 36 Rx

    4  Pages

  24. FHA 646 R

    1  Page

  25. FHAD46-7

    1  Page

  26. Psychrometer

    1  Page

  27. MH8D46

    2  Pages

  28. Pitot Tubes

    2  Pages

  29. Force

    3  Pages

  30. Displacement

    2  Pages

  31. Vibration

    2  Pages

  32. Speed

    1  Page

  33. Flow

    2  Pages

  34. Wind sensor

    2  Pages

  35. FLD733UVE

    2  Pages

  36. Sound Level

    1  Page

  37. Moisture

    5  Pages

  38. Tensiometer

    1  Page

  39. FLAD03VL1

    1  Page

  40. FLA623

    3  Pages

  41. VLambda

    1  Page

  42. FLD703UVE

    2  Pages

  43. Luminance

    1  Page

  44. pH

    4  Pages

  45. Conductivity

    2  Pages

  46. Certificates

    7  Pages

  47. WinControl

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.