Calibration certificates Temperature Caibration certificate for temperature measuring chains consisting of a contact temperature sensor and an instrument (also individual sensors). The calibration of the sensors or sensor + measuring instrument (measuring chain) is performed in a liquid bath, in a drywell calibrator or in a climatic chamber. DAkkS accredited Calibration Certificate DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025 (inter alia for the monitoring of production processes and the quality assurance applied to products). Calibration is performed by a DAkkS accredited laboratory which compares measured values against reference values based on national standards. Package offer (basic rate + 3 points 0 °C, 50 °C, 100 °C) KT9021D Measuring points, freely selectable: At least two calibration points are required for calibration Basic fee KT9001D Measuring point fee per sensor, one measuring point, temperature range up -100 to +1200 °C KT9011D Measuring point fee per sensor, one measuring point -196 °C KT9012D Factory Calibration Certificate Calibration compares measured values against reference values based on national standards. Package offer (basic rate + 3 points 0 °C, 50 °C, 100 °C) KT9021W Measuring points, freely selectable: At least two calibration points are required for calibration Basic fee KT9001W Measuring point fee per sensor, one measuring point, temperature range up -100 to +1200 °C KT9011W Measuring point fee per sensor, one measuring point -196 °C KT9012W Correction / adjustment of temperature sensors during first calibration To increase the accuracy, an adjustment of the probe is carried out during the initial calibration of a temperature probe. The correction values for zero point and slope are stored in the probe connector. The specified measured values in the certificate correspond to the corrected values. The correction can be performed as DAkkS accredited calibrations and factory calibrations. Calibration certificate - temperature - sensor deviation reduced to zero Multi-point adjustment for ALMEMO® measuring chains 11/2025 • We reserve the right to make technical changes. (preferably using Pt100 and NTC sensors) For the measurable variable temperature, for calibration packages and for single points (at least 2 temperature points, temperature point 0 °C obligatory), additional charge per sensor for factory calibration / DAkkS accredited calibration (German calibration service) KT9001DW Calibration and adjustment of the ALMEMO® measuring chain are performed for the whole of the sensors measuring range at the points in the calibration package. Calibration and adjustment of the ALMEMO® measuring chain (preferable using Pt100 and NTC sensors) are performed on the selected temperature points (temperature point 0 °C obligatory). Outside the calibrated range (below the lowest and above the highest calibration points) linear interpolation is performed up to the limits of the device`s measuring range (e.g. Pt100 0.01 K from -200 to +400 °C). During the calibration of the ALMEMO® measuring system, the sensor deviation is determined in every calibration point and then saved as correction value for that calibration point to the patented ALMEMO® plug. The measured values for such multi-point adjusted sensors are then listed in the calibration certificate. This means that the identified sensor deviations are close to zero. With thermocouples, as is generally the case, the indicated (adjusted) values in the calibration certificate are only valid if the device is in a stationary, thermally steady-state condition. Only for device types ALMEMO® 2450 (not -L), 2490 (not -L), 2470, 2590-2/-3S/-4S/-2A/-4AS, 2690, 2890, 4390, 8590, 8690, 5690, 5790, ALMEMO® V7-Measuring instruments und ALMEMO® X6-Reference measuring instrument. These device types as of serial number H0802xxxx incorporate this function as standard; for device types of serial number H0801 and below a device firmware update is possible (noted at incoming inspection as part of the calibration service). OA0006U Advisory note: On temperature sensors with special linearization or special measuring ranges saved to the ALMEMO® connector (e.g. ALMEMO® connector ZA9040SS3 NTC 0.001 K or ALMEMO® connectors with KTY84, YSI400, or customized NTC) multi-point adjustme
Open the catalog to page 1Calibration certificates Calibration certificate for temperature measuring chains consisting of an IR temperature sensor and an instrument (also individual sensors). DAkkS accredited Calibration Certificate DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025 (inter alia for the monitoring of production processes and the quality assurance applied to products). Calibration is performed by a DAkkS accredited laboratory which compares measured values against reference values based on national standards. For IR transmitters MR7834, MR7838,...
Open the catalog to page 2Calibration certificates Relative Air Humidity for capacitive humidity sensors / psychrometer Calibration certificate for humidity measuring chains consisting of capacitive humidity sensor / psychrometer and measuring instrument. DAkkS accredited Calibration Certificate The DAkkS accredited calibration meets the requirements of DIN EN ISO/IEC 17025 for test equipment (i.a. for monitoring production processes or qualification assurance of products). Calibration is performed by a DAkkS accredited laboratory which compares measured values against reference values based on national standards. Calibration...
Open the catalog to page 3Calibration certificates Calibration according to DIN 16005/16086. This calibration can be performed in 5 or 10 measuring points with pressure transducers or transducer + measuring instrument (measuring chain): to 400 bar, medium: gas to 700 bar, medium: oil DAkkS accredited Calibration Certificate DAkkS accredited calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025 (inter alia for the monitoring of production processes and the quality assurance applied to products). Calibration is performed by a DAkkS accredited laboratory which compares measured...
Open the catalog to page 4324 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
13 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
1 Page
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
4 Pages
2 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages