Software Software Description: • The AMR WinControl software package has been specially developed for data acquisition and measured data processing with ALMEMO® equipment. • This software makes it very easy and convenient for the user to program and operate ALMEMO® devices. • The acquired measured values can be displayed, arithmetically processed, stored, printed and for further data processing (also ONLINE) can be exported to other software packages. • It is possible to derive alarm conditions from the acquired or calculated variables and perform control measures. • The Windows desktop and the context-sensitive online help ensure a quick familiarisation and a safe handling of the software. • At our site (www.akrobit.de) you can find all the latest information regarding software versions and updates and also download the most recent trial version of the software. Software Versions: For 20 measuring points and one instrument For any number of measuring points and instruments For any number of measuring points and instruments, all options included (except Data server, Web server and additional modules) For any number of measuring points and devices, all options included (except add-on modules), with an integrated data server (simultaneous access by several RMT WinControl clients). Update of the latest software version for older versions Update of the latest software version for newer versions Options: Network capability (for addressing several ALMEMO® devices) Automatic generation of measured data files (daily files / weekly files) Modem support Alarm function (alarm record, output to ALMEMO® relays, starting other applications) Data server see 05.13 Web server see 05.14 New Extended evaluation functions see page 05.11 Additional modules Thermal comfort and air-conditioning calculations (as per DIN 1946, EN ISO 7730); (see 05.12) Password protection (see 05.12) Test bench manager (prerequisite : WC3 / WC4 or WC1 / WC2 + WCO2) (see 05.15) Thermal transmittance (U) wizard (see 06.11) Thermal quantity wizard (see 05.12 and chapter Building physics) OPC export (see 05.12) Additional protocol (selectable, requires WC3 / WC4) (see system integration, page 05.13) Security package (requires WC3 / WC4) (see 05.15) including watchdog card The memory is read out automatically (see 05.13 connecting options) Complete packages (see 05.13 - 05.14) Long-term / continuous monitoring PIMEX - combined measured value recording, video recording, and evaluation functions Hardware copy protection (see 05.15) USB dongle USB network dongle Minimum system requirements : Components : Minimum configuration Computer IBM-compatible PC Operating system Windows XP, 2003, Vista, 2008, 7, 8 (32 and 64 bit) Memory 256 MB Free hard-disk capacity 25 MB Interfaces USB 05.06 Recommended configuration IBM-compatible PC Windows 7 1024 MB 100 MB COM (RS232), USB,network card Modem or ISDN 10/2013 • We reserve the right to make technical changes. AMR WinControl the software for all ALMEMO® measu

Open the catalog to page 1
AMR WinControl the software for all ALMEMO - 2

Software Function overviewy Number of measuring points supported Number of connections supported Measured values - scanning Support for ALMEMO network ® Connection types Serial (COM), TCP/IP Modem, GSM, and wireless modem support Schedule-controlled connection setup Measured values - display Display of measured values (numeric, bar chart, wind rose, round gauges) Line graph (YT), XY graph Save / load presentation characteristics as format type Table, overview Zoom functions Project icons Work surfaces Measured values - saving Saving to hard disk - manual Saving to hard disk - automatic...

Open the catalog to page 2
AMR WinControl the software for all ALMEMO - 3

Software Averaging function (ONLINE and OFFLINE) Smoothing (over time / over number of values, ONLINE and OFFLINE) Data logger functions Programming the data logger (including averaging functions) Read out from device memory (all / selective measured values) Display of memory occupancy status Alarm functions Alarm value display in measuring points list and in all measured value displays Alarm report with confirmation and comments text Events list (audit trail) Start a program in the event of a particular fault Send e-mail / SMS in the event of an alarm Switch ALMEMO® output relays (specific...

Open the catalog to page 3
AMR WinControl the software for all ALMEMO - 4

Software Main Window/General View • The main window is the platform for all operations with AMR WinControl. All actions run within this window and can be minimised to a symbol, within the window or together with the window, and run in the background. • The measuring data can be presented as follows: Numeric presentation of measured values, bar diagram, wind rose, round instruments, line diagram, XY diagram, table, file overview. • Windows can be distributed over various work surfaces between which it is possible to switch by means of tabs. • The program can be operated by means of menu...

Open the catalog to page 4
AMR WinControl the software for all ALMEMO - 5

Data Logger Functions Device Lisi Saniplira Adk-ti the Fewcs Tine '.isinj th? | Apply Claai Memory I'Oiv- cad Samples fra~i Dsvks 'vier-s-j Data Selection: • The settings required for data logger operation can be programmed within a dia- • In the dialogue „Program Data Logger" the current settings of the device, e.g. memory occupancy, start and end time, measuring cycle and print cycle will be • The read-out of the device memory can be, individually or together, performed for all data loggers within the measuring network. • An optional setting allows to define that not all measured values...

Open the catalog to page 5
AMR WinControl the software for all ALMEMO - 6

Extended evaluation functions • Measured value files can be incorporated in new or already existing line charts in the form of comparative characteristics. • Folders containing a large number of measured value files can be conveniently grouped using various patterns based on file names and filters according to time and measuring point. • Local maximum and minimum values can be shown in a line chart as any measured value curve required. The search radius between maximum and minimum can be Data Export: • The data files can be, ONLINE and/or at any later point in time, stored in the fol-...

Open the catalog to page 6

All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures

  1. Product Catalog

    348 Pages

  2. FPAD 36-3

    2 Pages

  3. FLD7 33-UVE

    2 Pages

  4. FHAD 46-DTC2

    1 Pages

  5. ALMEMO® 204

    3 Pages

  6. AMiR 7834

    6 Pages

  7. ALMEMO® D6

    1 Pages

  8. MH8D46

    2 Pages

  9. FHAD46-7

    1 Pages

  10. FHA 646 R

    1 Pages

  11. Thermo-wires

    3 Pages

  12. ALMEMO® 5690

    10 Pages

  13. Product Catalog

    329 Pages

  14. CO2 sensor

    2 Pages

  15. FLA623

    3 Pages

  16. Pitot Tubes

    2 Pages

  17. FHAD 36 Rx

    4 Pages

  18. ALMEMO ® D6

    2 Pages

  19. FHA 696 GF1

    1 Pages

  20. FLA 613 VLK

    2 Pages

  21. FLAD23CCT

    2 Pages

  22. AMiR 7838

    6 Pages

  23. FD 8214

    2 Pages

  24. FMD7-60

    3 Pages

  25. T 820-6

    2 Pages

  26. ALMEMO 2490

    2 Pages

  27. ALMEMO ® 5690

    10 Pages

  28. ALMEMO ®

    3 Pages

Archived catalogs