Infrared measuring technology • Compact, robust and precise infrared measuring heads. • Wide range of versions for applications in intelligent process control and monitoring systems, as well as in production and test lab. • Low cost standard version with fixed set temperature and output current range and emissivity can be manually set at the measuring head. • The standard version without programming functions is ideally suitable for connecting to ALMEMO® devices. • Measuring heads also available as addressable and remotely programmable versions. Accessories ALMEMO® connecting cable, 2 meters, ALMEMO® connector, programmed for the probe head’s temperature range, Sensor supply via ALMEMO® device (use of the device mains unit is recommended) (cable not suitable for ALMEMO® 4490-2, available here on request) for programmable measuring heads MR7838xP Protective window, snap-on, according to above lens detail Remote control set incl. HART adapter and software Industrial mains adapter 110/220V – 24VDC Options Other focus point optics (also see page 07.44 / 07.45) Water/air cooling housing including air blow attachment, factory mounted Inherent safety (Ex in IIC T4), only available with programmable meas. heads without cooling jacket Factory test certificate, based on DAkkS/NIST certified sensors (only with delivery of new devices) Types (incl. rigid mounting angle and fastening screw) For universal applications, standard optics OR7838OS1 (Fresnel Lens) Meas. range –18 to 500°C, spectral range 8 to 14 µm, response time 165ms, optical resolution 15:1 MR783810(P) For universal applications, standard optics OR7838OS3 (Amtir Lens) Meas. range –18 to 500°C, spectral range 8 to 14 µm, response time 165ms, optical resolution 33:1 MR783811(P) For high temperature measurements in metal finishing and in rotary tubular kilns, standard optics OR7838OS3 (Sapphire Lens) Meas. range 200 to 1000°C, spectral range 3.9 µm, response time 165ms, optical resolution 33:1 MR783821(P) For maximum temperature measurements in metal finishing, standard optics OR7838OS6 (Float Glass Lens) Meas. range 500 to 2000°C, spectral range 2.2 µm, response time 100ms, optical resolution 60:1 MR783851(P) For high temperature measurements in glass production and at heating up and hardening, standard optics OR7838OS3 (Calcium Fluoride Lens) Meas. range 250 to 1650°C, spectral range 5.0 µm, response time 165ms, optical resolution 33:1 MR783831(P) For low temperature measurements in the production of plastic foils and normal foils, standard optics OR7838OS3 (Calcium Fluoride Lens) Meas. range 10 to 360°C, spectral range 7.9 µm, response time 165ms, optical resolution 33:1 MR783841(P) (P) Measuring heads remotely programmable DAkkS- oder Factory calibration KI9xxx temperature for sensor (see chapter Calibration certificates). DAkkS calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025. 10/2013 • We reserve the right to make technical changes. Infrared Measuring
Open the catalog to page 1Infrared measuring technology Device Functions only AMiR 7838-xxP (programmable AMiR Heads) Programming: through PC via HART® adapter (OR7838SH) Emissivity: 0.10 to 1.00 programmable Data functions: max, min, average value hold, compensation of ambience radiation Limit value programming: 1 limit value incl. hysteresis, also usable for monitoring the temperature of the measuring head ALMEMO® application: To acquire and save measured values using those measuring head variants which cannot be addressed and remotely programmed we recommend our ALMEMO® 4390-2 panel meters. For other ALMEMO®...
Open the catalog to page 2Infrared measuring technology HART® protocol: Single installation: Parallel working: Configuration examples: The Hart® protocol (´Highway Accessible Remote Transducer Protocol´) is one of the most popular intelligent field bus protocols. It is more often used in industry than any other protocol and is supported by a large number of products and software of other manufacturers. The Hart® signal combines the standard output of 4 to 20mA with a simultaneously running digital remote data transmission. As a result, the measuring heads can, additionally, digitally communicate through the...
Open the catalog to page 3Infrared measuring technology Meas. Spot Diameter [mm] Meas. Spot Diameter [mm] Measuring Field Diagrams: AMiR 7838-11(P)/-21(P)/-31(P)/-41(P) Distance Sensor - Test Object [mm] *Focus Point E : M = 30 : 1 Distant Field E : M = 5 : 1 Distance Sensor - Test Object [mm] *Focus Point E : M = 33 : 1 Distant Field E : M = 30 : 1 The devices AMiR 7838-31(P) and AMiR 7838-41(P) are only available with standard optics OS3. Focal Point Optics OS4 Meas. Spot Diameter [mm] Distance Sensor - Test Object [mm] *Focus Point E : M = 32 : 1 Distant Field E : M = 10 : 1 Focal Point Optics OS5 Meas. Spot...
Open the catalog to page 4Infrared measuring technology Accessories for All Measuring Heads AMiR 7838, 7845, 7850 Without Use of the Thermojacket Protective Housing Tube Adapter Measuring Head Measuring Head Cooled Housing adjustable tube adapter angle bracket Rigid mounting angle (spare) ZR7838H Adjustable mounting angle ZR7838JH Fastening screw (spare) ZR7838BM Tube adapter onto 11/2" NPT ZR7838RA
Open the catalog to page 5Infrared measuring technology Accessories for All Measuring Heads AMiR 7838, 7845, 7850 With Use of the Thermojacket Protective Housing adjustable tube adapter End Adapter Mounting Flange with Viewing Tube Smart Version Intermediate Ring Front Adapter ThermoJacket Housing special steel viewing tube adjustable mounting stand 10/2013 • We reserve the right to make technical changes. Connecting Flange with Stopper ceramic viewing tube adjustable mounting flange Thermojacket protective housing (3.26kg) Adjustable mounting stand Adjustable mounting flange Mounting flange for anti-reflective tube...
Open the catalog to page 6All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures
-
Measuring instruments and sensors
372 Pages
-
Product Catalog
348 Pages
-
FPAD 36-3
2 Pages
-
Electrical variables
2 Pages
-
FLD7 33-UVE
2 Pages
-
Optical radiation ALMEMO® D7
2 Pages
-
FHAD 46-DTC2
1 Pages
-
ALMEMO® 2490-1L
1 Pages
-
ALMEMO® 204
3 Pages
-
AMiR 7834
6 Pages
-
ALMEMO® D6
1 Pages
-
ALMEMO® 470-1
4 Pages
-
ALMEMO® 1033-2
1 Pages
-
MH8D46
2 Pages
-
FHAD46-7
1 Pages
-
FHA 646 R
1 Pages
-
Connector for thermocouples
1 Pages
-
Glass thermometer
1 Pages
-
Pt100 cable sensor
1 Pages
-
Thermo-wires
3 Pages
-
ALMEMO® 1030
2 Pages
-
ALMEMO® 8590 / 8690
2 Pages
-
ALMEMO® 5690
10 Pages
-
ALMEMO® 2890
2 Pages
-
ALMEMO® 2690
2 Pages
-
ALMEMO® 2590
3 Pages
-
ALMEMO® 2470
3 Pages
-
ALMEMO ® 8036
3 Pages
-
ALMEMO ® 500
3 Pages
-
Product Catalog
329 Pages
-
D6 connectors
1 Pages
-
OCX Win Control
1 Pages
-
ALMEMO® Control
4 Pages
-
CO2 sensor
2 Pages
-
conductivity D7
2 Pages
-
FLA623
3 Pages
-
Comfort Index
2 Pages
-
Modules for DC
1 Pages
-
Pressure sensors FDA602L
1 Pages
-
D6 Anemometer
1 Pages
-
Pitot Tubes
2 Pages
-
Digital sensor for humidity
3 Pages
-
FHAD 36 Rx
4 Pages
-
ALMEMO® 1036
2 Pages
-
ALMEMO® 1020
3 Pages
-
ALMEMO® 2490
2 Pages
-
ALMEMO® 2450
2 Pages
-
General accessories
3 Pages
-
Instrument Cases
1 Pages
-
ALMEMO ® Control : Software
4 Pages
-
Software ALMEMO ® View
1 Pages
-
ALMEMO ® D6
2 Pages
-
Pressure FDAD 12 SA
1 Pages
-
Sound Level MA 86193
1 Pages
-
FHA 696 GF1
1 Pages
-
Heat Flow Plates FQAx
2 Pages
-
Moisture Sensor FHA 696 MF
4 Pages
-
Radiation probe FLA 623 x
3 Pages
-
FLA 613 VLK
2 Pages
-
FLAD23CCT
2 Pages
-
Sensor FYAD 00 CO2B10
2 Pages
-
Transducer FYA600O3
1 Pages
-
AMiR FIA 844 s
2 Pages
-
FD 8214
2 Pages
-
FMD7-60
3 Pages
-
EEPROM FH0D 46- C
1 Pages
-
T 820-6
2 Pages
-
ALMEMO ® 202
2 Pages
-
ALMEMO 2490
2 Pages
-
ALMEMO ® 2470
3 Pages
-
ALMEMO ® 2690-8A
2 Pages
-
ALMEMO ® 5690
10 Pages
-
ALMEMO ® 1030-2
1 Pages
-
ALMEMO ® 1036-2
2 Pages
-
ALMEMO transmiter 2450/2490
2 Pages
-
ALMEMO ® 4390-2
1 Pages
-
ALMEMO ® 809
2 Pages
-
ALMEMO ®
3 Pages
Archived catalogs
-
Infrared Measuring Technique
24 Pages
-
Gas concentration in air
6 Pages
-
Water Analysis
8 Pages