Catalog excerpts
Infrared measuring technology • Precise measurement of the surface temperature in industrial processes. • New: sturdy stainless steel housing, protection class IP65. • Broad temperature range from -40 to 2000 °C. • Several spectral ranges for a variety of materials and use cases. • Emissivity of the measuring surface can be manually adjusted on the probe head. • Several optical resolutions and focal points. • New: integrated laser (except 7834-10) for easy positioning of the probe head. Supply of the laser via the USB port. • Analog output 4 to 20 mA in two-wire technology. • New: USB port for configuring the analog output range, further probe head parameters and the signal processing (average value, maximum value, and minimum value). • Easy installation. Extensive range of accessories, i.a. a high temperature protective housing. • Connection cable for ALMEMO® data logger. Sensor power supply via the ALMEMO® device. On request: Intrinsically safe probe heads approved for various purposes in areas with potentially explosive atmosphere (gas/dust). Measuring Spectral range Optical resolution / focal point Order no. (refer to Measuring Field Diagrams) range AMiR 7834-10x. without laser. with plastic lens. i.a. suitable for food etc. MR783410SF0 AMiR 7834-10SF0 -20 to 600 °C 8 to 14 µm 15:1 / 101.3 mm at 1520 mm MR783410CF0 AMiR 7834-10CF0 -20 to 600 °C 8 to 14 µm 7:1 / 7.1 mm at 50 mm AMiR 7834-11x/-12x with laser, for low temperature measurements, i.a. thick plastics, asphalt, carpets, coated papers, thermoforming etc. MR783411SF0 AMiR 7834-11SF0 -20 to 600 °C 8 to 14 µm 33:1 / 46.1 mm at 1520 mm MR783411CF1 AMiR 7834-11CF1 -20 to 600 °C 8 to 14 µm 33:1 / 2.3 mm at 76 mm MR783411CF2 AMiR 7834-11CF2 -20 to 600 °C 8 to 14 µm 33:1 / 6.1 mm at 200 mm MR783412SF0 AMiR 7834-12SF0 -40 to 1000 °C 8 to 14 µm 50:1 / 30.4 mm at 1520 mm MR783412CF2 AMiR 7834-12CF2 -40 to 1000 °C 8 to 14 µm 50:1 / 4 mm at 200 mm AMiR 7834-21x with laser, for blast furnace lining, flame hardening, brazing etc. MR783421SF0 AMiR 7834-21SF0 200 to 1000 °C 3.9 µm 33:1 / 46.1 mm at 1520 mm MR783421CF1 AMiR 7834-21CF1 200 to 1000 °C 3.9 µm 33:1 / 2.3 mm at 76 mm MR783421CF2 AMiR 7834-21CF2 200 to 1000 °C 3.9 µm 33:1 / 6.1 mm at 200 mm AMiR 7834-31x with laser, for surface temperatures of glass for bending, hardening, glowing, sealing etc. MR783431SF0 AMiR 7834-31SF0 250 to 2250 °C 5 µm 33:1 / 46.1 mm at 1520 mm AMiR 7834-41x with laser, for foils PET, FEP, acryl, nylon, PU, PVC etc. MR783441SF0 AMiR 7834-41SF0 10 to 360 °C 7.9 µm 33:1 / 46.1 mm at 1520 mm AMiR 7834-51x with laser, for ferrous metals / non-ferrous metals, induction heating, blast furnaces etc. MR783451SF0 AMiR 7834-51SF0 500 to 2000 °C 2.2 µm 60:1 / 25.3 mm at 1520 mm MR783451CF1 AMiR 7834-51CF1 500 to 2000 °C 2.2 µm 60:1 / 1.3 mm at 76 mm MR783451CF2 AMiR 7834-51CF2 500 to 2000 °C 2.2 µm 60:1 / 3.3 mm at 200 mm DAkkS- oder Factory calibration KI9xxx temperature for sensor (see chapter Calibration certificates). DAkkS calibration meets all the requirements regarding test resources laid down in DIN EN ISO/IEC 17025. 11/2019 • We reserve the right to make technical changes. Infra-red transmitter for measuring the surface temperature AMiR 7843 probe head for indust
Open the catalog to page 1Infrared measuring technology Technical data: Accuracy: ±1% of the measured value respectively ±1.0 K for the measured temperature > 0°C, (whichever value is higher). for measured temperature < 0°C: ±(1.0 K +0.1 x (0°C – measured temperature)). measured temperature in °C Reproducibility: ±0,3% of measured value respectively ±0.3 K (whichever value is higher). Response time: 130 ms, for 7834-11 30ms, for 7834-31 60 ms Nominal conditions: +23°C ±5 K, Emissivity factor 1.0 and calibration geometry Emissivity: 0.10 to 1.00 manually adjustable on the probe head Signal processing: Averaging,...
Open the catalog to page 2Infrared measuring technology 11/2019 • We reserve the right to make technical changes. Measuring Field Diagrams AMiR 7834-11SF0 AMiR 7834-21SF0 AMiR 7834-31SF0 AMiR 7834-41SF0
Open the catalog to page 3Infrared measuring technology 11/2019 • We reserve the right to make technical changes.
Open the catalog to page 4Infrared measuring technology Accessories Protective window attached for probe head MR 7834-10x, material: plastic foil Protective window attached for probe head MR 7834-11x/-12x, material: zinc sulfide Protective window attached for probe head MR 7834-21x, material: sapphire Protective window attached for probe head MR 7834-31x/-41x, material: calcium fluoride Protective window attached for probe head MR 7834-51x, material: glass Water cooling housing including air blower attachment Air blower attachment Deflecting mirror 90° Mounting bracket, adjustable Mounting bracket, rigid (spare)...
Open the catalog to page 5Infrared measuring technology 11/2019 • We reserve the right to make technical changes. Accessories for the probe heads AMiR 7834 using the thermo jacket protection housing Accessories Thermo jacket protection housing Mounting flange for thermo jacket Adjustable mounting flange for thermo jacket Adjustable tube adapter for thermo jacket Mounting flange for protective tubes for thermo jacket Stainless steel protective tube, 30 cm Ceramic protective tube, 30 cm
Open the catalog to page 6All Ahlborn Mess- und Regelungstechnik GmbH catalogs and technical brochures
-
Measuring instruments and sensors
372 Pages
-
Product Catalog
348 Pages
-
FPAD 36-3
2 Pages
-
Electrical variables
2 Pages
-
FLD7 33-UVE
2 Pages
-
Optical radiation ALMEMO® D7
2 Pages
-
FHAD 46-DTC2
1 Pages
-
ALMEMO® 2490-1L
1 Pages
-
ALMEMO® 204
3 Pages
-
ALMEMO® D6
1 Pages
-
ALMEMO® 470-1
4 Pages
-
ALMEMO® 1033-2
1 Pages
-
MH8D46
2 Pages
-
FHAD46-7
1 Pages
-
FHA 646 R
1 Pages
-
Connector for thermocouples
1 Pages
-
Glass thermometer
1 Pages
-
Pt100 cable sensor
1 Pages
-
Thermo-wires
3 Pages
-
ALMEMO® 1030
2 Pages
-
ALMEMO® 8590 / 8690
2 Pages
-
ALMEMO® 5690
10 Pages
-
ALMEMO® 2890
2 Pages
-
ALMEMO® 2690
2 Pages
-
ALMEMO® 2590
3 Pages
-
ALMEMO® 2470
3 Pages
-
ALMEMO ® 8036
3 Pages
-
ALMEMO ® 500
3 Pages
-
Product Catalog
329 Pages
-
D6 connectors
1 Pages
-
OCX Win Control
1 Pages
-
ALMEMO® Control
4 Pages
-
CO2 sensor
2 Pages
-
conductivity D7
2 Pages
-
FLA623
3 Pages
-
Comfort Index
2 Pages
-
Modules for DC
1 Pages
-
Pressure sensors FDA602L
1 Pages
-
D6 Anemometer
1 Pages
-
Pitot Tubes
2 Pages
-
Digital sensor for humidity
3 Pages
-
FHAD 36 Rx
4 Pages
-
ALMEMO® 1036
2 Pages
-
ALMEMO® 1020
3 Pages
-
ALMEMO® 2490
2 Pages
-
ALMEMO® 2450
2 Pages
-
General accessories
3 Pages
-
Instrument Cases
1 Pages
-
ALMEMO ® Control : Software
4 Pages
-
Software ALMEMO ® View
1 Pages
-
ALMEMO ® D6
2 Pages
-
Pressure FDAD 12 SA
1 Pages
-
Sound Level MA 86193
1 Pages
-
FHA 696 GF1
1 Pages
-
Heat Flow Plates FQAx
2 Pages
-
Moisture Sensor FHA 696 MF
4 Pages
-
Radiation probe FLA 623 x
3 Pages
-
FLA 613 VLK
2 Pages
-
FLAD23CCT
2 Pages
-
Sensor FYAD 00 CO2B10
2 Pages
-
Transducer FYA600O3
1 Pages
-
AMiR FIA 844 s
2 Pages
-
AMiR 7838
6 Pages
-
FD 8214
2 Pages
-
FMD7-60
3 Pages
-
EEPROM FH0D 46- C
1 Pages
-
T 820-6
2 Pages
-
ALMEMO ® 202
2 Pages
-
ALMEMO 2490
2 Pages
-
ALMEMO ® 2470
3 Pages
-
ALMEMO ® 2690-8A
2 Pages
-
ALMEMO ® 5690
10 Pages
-
ALMEMO ® 1030-2
1 Pages
-
ALMEMO ® 1036-2
2 Pages
-
ALMEMO transmiter 2450/2490
2 Pages
-
ALMEMO ® 4390-2
1 Pages
-
ALMEMO ® 809
2 Pages
-
ALMEMO ®
3 Pages
Archived catalogs
-
Infrared Measuring Technique
24 Pages
-
Gas concentration in air
6 Pages
-
Water Analysis
8 Pages