Input connectors for Pt100Digital ALMEMO® D7 measuring connector for Pt100 / Pt1000 temperature sensorHigh-level resolution of 0.01 K across the entire measuring range up to 850 °C Linearization of the Pt100 / Pt1000 characteristic calculated Calibration with greater accuracy by subjecting the temperature sensor to multi-point adjustment Only for latest ALMEMO® V7 measuring instruments, AlMEMO® 202-S, 204, 104, 710, 510, 809. The new ALMEMO® D7 measuring connector provides even greater precision! • The digital ALMEMO® D7 measuring connector uses its own integrated A/D converter. It provides a high-level resolution of 0.01 K across the entire measuring range up to 850 °C. Linearization of the Pt100 / Pt1000 characteristic is calculated in compliance with DIN IEC 751 (not an approximation). • The overall accuracy of the measuring operation is unaffected by the presence of an ALMEMO® V7 display device / data logger. The whole measuring chain, comprising e.g. a Pt100 / Pt1000 sensor and the connected ALMEMO® D7 measuring connector, can be calibrated end-to-end. Calibration can be performed with greater accuracy by subjecting the temperature sensor to a process of multi-point adjustment. The measuring rate is determined entirely and exclusively by the integrated A/D converter. On the ALMEMO® V7 measuring instrument all D7 measuring connectors operate in parallel at their own measuring rate. The measuring instruments very short scan cycle is determined by the measuring rates of the D7 measuring connectors - irrespective of their number. Sensor identification can be programmed with designations up to 20 characters in length. 11/2025 • We reserve the right to make technical changes. Technical data Sensor type Pt100, 4 conductors or Measuring input electrically interconnected with the power supply (ALMEMO® device ground) Measuring range -200 to +850 °C Conversion rate 10 mops Measuring current Linearization calculated Temperature drift 0.003 % / K (30 ppm) (resistance) Supply voltage from 6 V up from ALMEMO® device (sensor supply voltage) Current consumption approx. 9 mA Environmental conditions see general technical specifications Types: Type
Open the catalog to page 1Input connectors for Pt100Digital ALMEMO® D6 measuring connector for Pt100 temperature sensorDigital temperature sensors now also for ALMEMO® V6 measuring instruments, e.g. ALMEMO® 5690, 2690, 2590 Resolution of 0.01 K across the entire measuring range up to 400 °C Linearization of the Pt100 characteristic calculatedCalibration with greater accuracy by subjecting the temperature sensor to multi-point adjustment The new ALMEMO® D6 measuring connector provides even greater precision! 11/2025 • We reserve the right to make technical changes. Technical data and functions • The digital ALMEMO® D6...
Open the catalog to page 2Input connectors for Pt100Digital ALMEMO® D7 Precision measuring connector for Pt100 temperature sensor, resolution 0.001 KDigital precision measuring connector with highest resolution of 0.001 K across the entire measuring range up to 850 °C Linearization of the Pt100 characteristic calculatedCalibration with greater accuracy by subjecting the temperature sensor to multi-point adjustment For ALMEMO® V7 measuring instruments, ALMEMO® 202-S, 204, 104, 710, 510, 809. The new ALMEMO® D7 measuring connector provides even greater precision! Digital precision resistance sensor Pt100 FPD723L0250A3D...
Open the catalog to page 3The self-heating must be included in the measurement uncertainty: If the self-heating is NOT known for the sensor design at hand, a lump sum must be charged. Example: For a sufficiently long sheath element, an amount of 17 mK is recommended. In comparison: For the Ahlborn precision probe FPA923/FPD723 the self-heating was determined and is included in the measurement uncertainty with typ. 2 mK. The hysteresis must be described in addition to the measurement uncertainty: If the hysteresis is not determined, a lump sum of up to 0.2 % of the span is recommended in international regulations. Example:...
Open the catalog to page 4Model Meas. Range Resolution Data may vary depending on device; (see data sheet per device) Types: Model Meas. Range Resolution 11/2025 • We reserve the right to make technical changes. Technical Data ZA9003SS4: Connection 2-wire Linearization accuracy: ±0,2 % ± 0,02 kOhm Linearization is saved in the ALMEMO® connector; (this is not _available with ALMEMO® 2450, 8390) Model Meas. Range Resolution Data may vary depending on device; (see data sheet per device)
Open the catalog to page 58 Pages
2 Pages
3 Pages
4 Pages
316 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
1 Page
14 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
13 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages