Reference Measuring Instruments ALMEMO® Reference measuring instruments for humidity and temperature High-precision measurement with the Pt100 psychrometer and Pt100 sensors Resolution Temperature 0.001 K Relative humidity 0.01 % Dew point 0.01 K Technical features • Humidity measurement with very high resolution, precision, and linearity, using Pt100 psychrometer • Suitable as reference device in calibration laboratories and quality assurance procedures • Very high level of accuracy using the Pt100 psychrometer thanks to multi-point adjustment of the two temperature sensors • Pt100 psychrometer optimized for measuring operations involving high humidity levels performed over long periods • Automatic atmospheric pressure compensation is provided for pressure-dependent humidity variables by means of a digital atmospheric pressure sensor integrated in the ALMEMO® device. • Humidity calculation on the basis of formulae as per Dr. Sonntag and the enhancement factor as per W. Bögel (correction factor fw(t,p) for real mixed gas systems). This substantially widens the measuring range and improves the accuracy of humidity variable calculations. • Resolution: Temperature Pt100 0.001 K, Relative humidity 0.01 %, Dew point 0.01 K • The humidity variables are calculated from the three primary measuring channels (real measurable variables). Dry temperature (°C), humid temperature (°C), atmospheric pressure (mbar) • Three humidity variables displayed simultaneously, freely selectable: Relative humidity (%), dew point (°C), mixture (g/kg), Absolute humidity (g/m³), vapor pressure (mbar), enthalpy (kJ/ kg) • Two electrically isolated measuring inputs for Pt100 sensors • High-resolution A/D converter, delta-sigma, 24-bit, 1.25 mops (measuring operations per second) • Two output sockets for digital interface, ALMEMO® memory connector • Compact, modern, ergonomic design • Graphics display, illuminated with white light • Easy and convenient to operate by means of 4 soft-keys and cursor block • Measured value display: Sensor display (up to 4 measured values), measuring points list, atmospheric pressure • Measuring functions: Zero-setting, smoothing, maximum / minimum values, individual value memory for 100 values • Data logger with ALMEMO® memory connector (accessory) • Sensor programming: Smoothing, designation, measuring range selection, locking • Device configuration: Illumination, contrast, device address, baud rate, atmospheric pressure • Choice of language: German, English, French • Humidity measurement in temperature range -100 to +200 °C, with precision digital capacitive temperature / humidity sensors FHAD 36 Rx, with ALMEMO® D6 connector (Accessories, see chapter „Atmospheric humidity“). Configuration of ALMEMO® D6 sensors on ALMEMO® device itself. For the digital sensors FHAD 36-Rx, it is not possible to program the multi-point adjustment via the measuring instrument. Technical data ALMEMO® 1036-2 Measuring inputs Two ALMEMO® input sockets for Pt100 psychrometer FPA 836-3P3 or Precision digital capacitive tempera ture / humidity sensors FHAD 36 Rx Electrical isolation Semiconductor relay (50 V) A/D converter Delta-sigma, 24-bit, 1.25 mops Measuring range Pt100, -200 to +400 °C Resolution 0.001 K Measuring current 1 mA Measuring method ratiometric Accuracy ±0.010 K ±1 digit in range -50 to +400 °C Nominal conditions 23 °C ±2 K, 1013 mbar, battery mode Temperature drift typical 2 ppm / K Calculated humidity quantities Analytic equation (not an approximation) Digital atmospheric pressure sensor (integrated in the device) Measuring range 700 to 1100 mbar Accuracy ±2.5 mbar (at 23 °C ±5 K) Two ALMEMO® sockets for interface cable and ALMEMO® memory connector Standard equipment Display Graphics display, 128 x 64 pixels, 8 rows Illumination 2 white LEDs Keypad 7 silicone keys (of which 4 soft-keys) Date and time-of-day Real-time clock, buffered by battery Individual value memory, internal 100 measured values Power supply Battery set 3 AA alkaline batteries Mains adapter ZA1312NA12 100 to 240 VAC to 12 VDC, 1.5 A, electrically isolated Current consumption (without input and output modules) approx. 20 mA With illumination approx. 40 mA Housing Ambient conditions see general technical specifications
Open the catalog to page 1Reference Measuring InstrumentsAccessories Order no. Ethernet data cable ALMEMO® memory connector with micro SD Rubberized impact protection, gray DIN rail mounting Spare wicks (2 pieces) Set with Pt100 psychrometer FPA 836-3P3 Psychrometer FPA 836-3P3 Operating temperature 0...+90 °C (no ice formation) Humidity measuring range approx. 10 to 100 % RH Measuring system psychrometric Temperature sensors sheet resistance 2 x Pt100 class B, ALMEMO® adjusted Housing Dimensions Ventilator power supply Connecting cables ALMEMO® plug Plastic PMMA 175 x 50 x 75 mm (LxWxH) 12 VDC via mains unit cable, approx....
Open the catalog to page 2324 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
2 Pages
8 Pages
6 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
3 Pages
14 Pages
5 Pages
2 Pages
5 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
13 Pages
1 Page
1 Page
1 Page
5 Pages
3 Pages
1 Page
4 Pages
1 Page
1 Page
3 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
5 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
2 Pages
2 Pages
1 Page
4 Pages
2 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages