Catalog excerpts
X-Series Measurement Applications ● Accelerate your designs with Agilent's first-to-market leadership in emerging standards ● Address ever-changing measurement needs in cellular communications, wireless connectivity, digital video, and general-purpose applications ● Get flexibility when you need it with applications that are transportable between X-Series signal analyzers
Open the catalog to page 1X-Series Measurement Applications A consistent measurement framework Expand the capabilities of your X-Series signal analyzer with the industry’s broadest offering of measurement applications. A shared library of more than 25 measurement applications increases the capability and functionality of the X-Series analyzers to speed your time to insight, providing essential measurements for specific tasks in cellular communications, wireless connectivity, digital video, and general-purpose. Realize measurement integrity across your organization with consistent operation and test methods, proven...
Open the catalog to page 3Enhance and customize your data analysis power With the open Windows® OS, you can create customized demodulation macros and run applications such as MATLAB to further analyze and visualize your wireless data, execute and test modulation schemes, and develop automated tests. Try Before You Buy! Free 30-day trials of X-Series measurement applications provide unrestricted use of each application’s features and functionality on your X-Series analyzer. Redeem a trial license on-line today: Choosing Between X-Series Applications and 89600 VSA Software X-Series measurement applications provide...
Open the catalog to page 4Product Summary Cellular communications Measurement application model number1 W-CDMA/ HSPA+ iDEN/WiDEN/ MotoTalk Mobile WiMAX Fixed WiMAX DTMB (CTTB) 1. Application model numbers with an “N” prefix are for PXA, MXA, and EXA signal analyzers and MXE EMI receiver. Application model numbers with a “W” prefix are for the CXA signal analyzer. 2. 802.11ac is not available for CXA 5 License type (perpetual) Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable...
Open the catalog to page 5Product Summary General purpose Measurement application model number1 License type (perpetual) Fixed, transportable Analog demodulation Phase noise Noise figure VXA vector signal analysis SCPI command language compatibility Remote language compatibility Fixed, transportable Fixed, transportable Fixed, transportable Fixed, transportable Fixed Fixed 1. Application model numbers with an “N” prefix are for PXA, MXA, and EXA signal analyzers and MXE EMI receiver. Application model numbers with a “W” prefix are for the CXA signal analyzer. 2. N6171A and N9051A also run on CXA. Built-in Help...
Open the catalog to page 6Cellular Communications The cellular communications measurement applications cover a full range of technolo- gies—from existing 2G/3G/3.5G systems to evolving 4G communication systems. These measurement applications adhere to the 3GPP and 3GPP2 standards, and closely follow standards as they change, allowing you to stay on the leading edge of your design and manufacturing challenges. • Supports 3GPP Release 9 LTE standard * Downlink and uplink analysis in a single option • Transmitter characteristic measurements, including ° Base station (eNB): EVM, freq error, DL RS power, RSTP, OSTP, SEM,...
Open the catalog to page 7Multi-Standard Radio (MSR) • Supports 3GPP Release 10 MSR standard • Transmitter test on combination of 2G, 3G, and 4G signals • One-button measurements including ◦◦ Modulation quality: EVM, frequency error ◦◦ Spectrum measurements: Channel power, spectrum emission mask (SEM), adjacent channel power (ACP), transmitter spurious emissions • Automatic sequencing function to eliminate the need for wide analysis bandwidth option • Carrier allocating algorithm with preset selection based on contiguous and non-contiguous test configuration definitions in 3GPP standard Figure 3. Multi-Standard...
Open the catalog to page 8GSM, EDGE, and EDGE Evolution per 3GPP GERAN Analysis of both base and mobile stations in a single option One-button transmitter measurements, including ° Base station: EVM, phase and frequency error, output RF spectrum (ORFS), power vs. time (PvT) ° Mobile station: EVM, phase and frequency error, ORFS, PvT.TX band spur Multicarrier BTS (MCBTS) and adaptive QPSK (AQPSK) modulated VAMOS measurements per Rel-9 of 3GPP Analog baseband analysis with PXA or MXA Option BBA (BBIQ inputs) 1 CH Frig: 935.200 000 MHz(ARFCN: 1) Radio Band: P-GSM Trig: EdernaM Avg|Hold: 10/10 Burst: TCH&CCH BTS...
Open the catalog to page 91xEV-DO per Rel 0, Rev A and Rev B of 3GPP2 standard Analysis of both forward link and reverse link in a single option Auto detection for data channels QPSK, 8PSK, 16QAM, and 64QAM One-button Tx measurements with pass/fail per 3GPP2 standard, including ◦◦ Modulation accuracy: composite EVM and Rho, CDP, CDE, I/Q chip error ◦◦ Power and spectrum measurements: channel power, power vs. time, ACP, SEM, spurious emissions • Analog baseband analysis with PXA or MXA Option BBA (BBIQ inputs) cdma2000/cdmaOne • cdmaOne and cdma2000 per 3GPP2 Release A • Analysis of forward link and reverse link in a...
Open the catalog to page 10iDEN, WiDEN, and MotoTalk, including WiDEN multi-carrier BTS with multiple slot formats 4QAM/16QAM/64QAM modulation formats 25/50/75/100/50-outer kHz bandwidths Analysis of both base station and mobile station in a single option One-button transmitter measurements, including ◦◦ Modulation accuracy: EVM, magnitude error, phase error, BER ◦◦ ACP, OBW, power vs. time
Open the catalog to page 11Wireless Connectivity ^ The wireless connectivity measurement applications cover a full range of technologies - from Bluetooth through 802.11 WLAN and 802.16e OFDMA Mobile WiMAX. As technol- ogy advances, X-Series measurement applications are also advancing to enable you to continue tackling increasingly complex design and manufacturing test challenges. IEEE 802.11 a/b/g/n/ac standard One-button, standard-based measurements with pass/fail tests ° l/Q demodulation measurements: modulation accuracy, power vs. time, spectral flatness, power stat CCDF ° Swept spectrum measurements: spectrum...
Open the catalog to page 12All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures
-
Agilent 280 Series AA Systems
12 Pages
-
Inorganic Standards
40 Pages
-
InfinityLab LC Supplies
148 Pages
-
General Chromatography
164 Pages
-
Sample Preparation (2018/2019)
144 Pages
-
MS500
12 Pages
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Pages
-
Agilent training
27 Pages
-
AGILENT VACUUM PRODUCTS CATALOG
536 Pages
-
Vacuum Measurement Catalog
44 Pages
-
AGILENT ION Pumps
53 Pages
-
AGILENT DIFFUSION PUMPS
35 Pages
-
AGILENT Rotary Vane Pumps
29 Pages
-
Agilent InfinityLab LC Series
16 Pages
-
3100 fractionator
8 Pages
-
4200 MP-AES
12 Pages
-
Agilent GPC/SEC Solutions
12 Pages
-
Agilent?s biomass solutions
12 Pages
-
X-ray Crystallography
12 Pages
-
Agilent ProPulse NMR System
5 Pages
-
An autosampler like no other
4 Pages
-
Agilent U1450A/U1460A
19 Pages
-
Agilent B1507A
22 Pages
-
Agilent M9703A
16 Pages
-
W1905 Radar Model Library
16 Pages
-
M8048A ISI Channels
7 Pages
-
Agilent J-BERT M8020A
27 Pages
-
Agilent N8900 Series
10 Pages
-
I/O Hardware
16 Pages
-
Advanced Design System
16 Pages
-
RF & Microwave Attenuators
4 Pages
-
E4980AL Precision LCR Meter
8 Pages
-
FieldFox Handheld Analyzers
8 Pages
-
AFM/SPM Accessories
20 Pages
-
VEE 9.32
24 Pages
-
89600 VSA Software
9 Pages
-
Command Expert
2 Pages
-
E5061B Network Analyzer
8 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
N9038A MXE EMI Receiver
2 Pages
-
N9322C Basic Spectrum Analyzer
10 Pages
-
Digital Multimeters
25 Pages
-
M9361A PXI Downconverter
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
Agilent Power Products
31 Pages
-
E5063A Network Analyzer
8 Pages
-
Leak Detection Catalog
41 Pages
-
Agilent 7820A GC brochure
8 Pages
-
Agilent GC-MSD and QTOF
96 Pages
-
Agilent GC-MSD 5977
39 Pages
-
Agilent Intro BERLIN
24 Pages
-
1290 Infinity Quaternary LC
24 Pages
-
1260 Infinity Bio-inert
26 Pages
Archived catalogs
-
Diffusion Pumps Catalog
37 Pages