N2100B Digital Communication Analyzer

N2100B Digital Communication Analyzer

N2100B Digital Communication Analyzer

Product catalog summary
Industries and Applications
  • Testing of Optical and Electrical Transceivers
  • Telecommunication Equipment Testing
  • Fibre Channel, Ethernet, PON, Parallel Optics
  • Multi-port System Testing
  • High Port Count Burn-in Testing
Product Description

The N2100B PXI Digital Communication Analyzer (DCA) combines real-time scope benefits with sampling scope bandwidth using a patented vector undersampling technique. It performs accurate eye diagram analysis for transmitters ranging from 155 Mb/s to 10.3125 Gb/s.

Models
  • N2100B PXI Digital Communication Analyzer Module
  • N2100B-300: 155 Mb/s to 10.3125 Gb/s
Main Features and Benefits
  • PON and 10 GigE filters available for extended test capabilities.
  • Smart Post Processing increases throughput for optical transceiver manufacturers.
  • ER Correction Factor ensures tighter correlation with other instruments.
  • Eye diagram, mask, and jitter testing in a single instrument for quality assessment and control.
  • Wide optical bandwidth coverage from 750 nm to 1650 nm for telecommunication and data communication testing.
  • Connector compatibility includes cPCI, PXI-H, PXI-1.
Specifications and Characteristics
  • Hardware: 4-slot module
  • Electrical Input: 1 channel, single-ended AC coupled, 1 V pp (max), 9.5 GHz bandwidth
  • Optical Input: 62.5/125 µm fiber, 750—1650 nm, 10.3125 Gb/s bandwidth
  • Sample Rate: 160 Ms/s
  • Waveform Acquisition: 1024 points per acquisition, max. 1024 acquisitions
  • Pattern Acquisition Mode: Max. 2047 bits pattern length, 128 points per bit, fixed
  • Clock Recovery: <2.7 Gb/s
  • Clock Input Frequency Range: 10 MHz to 11.318 GHz
  • Clock Input Voltage Range: 0.5 to 1 V pp
Software Information
  • Operating Systems: Microsoft Windows XP (32-bit), Windows 7 (32-bit, 64-bit)
  • Standard Compliant Drivers: IVI-COM, IVI-C, LabVIEW, MATLAB
  • Supported Application Development Environments: Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
  • Agilent IO Libraries: Includes VISA Libraries, Agilent Connection Expert, IO Monitor
Ordering Information

Typical Product Configuration requires choosing any 4 different filter rates from options ranging from 155 Mb/s to 10.3125 Gb/s.

  • Related Products: N2101B PXI Bit Error Ratio Tester, N2102B PXI Pattern Generator, N2099A PXI Synthesizer
Figures
  • Figure 1: Automatic Mask Test Measurement including a call to determine the margin that x number of points fail the “Mask Margin Test”.
  • Figure 2: Multiple measurements can be made at the same time.
See more

Catalog excerpts

N2100B Digital Communication Analyzer-1

Agilent N2100B Digital Communication Analyzer Ind u s t r i e s a nd A p p l i cat i o ns • Test of Optical and Electrical Transceivers • Telecommunication Equipment Test • Fibre Channel, Ethernet, PON, Parallel Optics • Multi-port system testing • High port count burn-in test Pr o d u c t D e s cr i p t i o n The N2100B PXI DCA combines the benets and measurement capabilities of a real time scope with the bandwidth of a sampling scope, using a coherent patented vector undersampling technique. The N2100B performs accurate eye diagram analysis to characterize the quality of transmitters from 155 Mb/s to 10.3125 Gb/s. Challenge the Boundaries of Test Agilent Modular Products PXI Digital Communication Analyzer Module 155 Mb/s to 10.3125 Gb/s M a i n F e a tu r e s and B e ne fi t s Spec ific ations and Charac teris tic s PON and 10 GigE filters available Extended test capabilities Smart Post Processing Allows optical transceiver manufacturers increase throughput Electrical input 1 channel, single ended AC coupled, 1 v pp (max) Enables even tighter correlation with other instruments Optical input Eye diagram, mask and jitter testing in a single instrument Allowing DUT’s quality assessment, control and binning Wide optical bandwidth coverage from 750 nm to 1650 nm Cover test of optical transmitters for telecommunication and data communication use Sample rate Waveform acquisition 1024 points per acquisition, max. 1024 acquisitions Pattern acquisition mode Max. 2047 bits pattern length, 128 points per bit, fixed Clock recovery Clock input frequency range Clock input voltage range Connector compatibility: cPCI, PXI-H, PXI-1

 Open the catalog to page 1
N2100B Digital Communication Analyzer-2

Ordering Information Software operating systems Microsoft Windows XP (32-bit) Windows 7 (32-bit, 64-bit) T yp i cal Prod uct Confi g urat i on Model Standard compliant drivers IVI-COM, IVI-C, LabVIEW, MATLAB PXI Digital Communication Analyzer Must choose any 4 different lter rates: Supported application development environments (ADE) Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB Includes: VISA Libraries, Agilent Connection Expert, IO Monitor PXI Bit Error Ratio Tester Figure 1. Automatic Mask Test Measurement including a call to determine the margin that x number of...

 Open the catalog to page 2

All Agilent Technologies - Life Sciences and Chemical catalogs and technical brochures

  1. MS500

    12  Pages

  2. 4200 MP-AES

    12  Pages

  3. Agilent B1507A

    22  Pages

  4. Agilent M9703A

    16  Pages

  5. I/O Hardware

    16  Pages

  6. VEE 9.32

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.